Товаров
  
корзина пуста
  • Каталог оборудования Siemens

dv/dt filters plus VPL

  • Заказные данные
    (12)
  • Информационные материалы

    Информационные материалы

    dv/dt filter plus VPL (Voltage Peak Limiter) limit the voltage rate-of-rise dv/dt to values < 500 V/μs and the typical voltage peaks to the following values in accordance with the limit value curve according to IEC/TS 60034‑17: 2006:

    < 1000 V at Uline < 575 V

    < 1250 V at 660 V < Uline < 690 V

    Standard motors with standard insulation and without insulated bearings with a supply voltage of up to 690 V can be used for converter operation if a dv/dt filter plus VPL is used.

    dv/dt filters plus VPL are designed for the following maximum motor cable lengths:

    • Shielded cables: 300 m (984 ft) (e.g. Protodur NYCWY)
    • Unshielded cables: 450 m (1476 ft) (e.g. Protodur NYY)

    For shorter cable lengths (100 m (328 ft) shielded, 150 m (492 ft) unshielded), see also dv/dt filter compact plus VPL.

    Notice:

    The maximum permissible cable length between the dv/dt filter plus VPL and the Power Module/Motor Module is 5 m (16.4 ft).

    Дизайн

    The dv/dt filter plus VPL consists of two components, which are also supplied as separate mechanical units:

    • dv/dt reactor
    • Voltage limiting network, which cuts off the voltage peaks and feeds the energy back to the DC link.

    Технические данные

    Line voltage 380 ... 480 V 3 AC

    dv/dt filter plus VPL

     

    6SL3000-2DE32-6AA0

    6SL3000-2DE35-0AA0

    6SL3000-2DE38-4AA0

    6SL3000-2DE41-4AA0

    Ith max

    A

    260

    490

    840

    1405

    Degree of protection

     

    IP00

    IP00

    IP00

    IP00

    Cable length, max.

    between dv/dt filter and motor 1)

     

     

     

     

     

    • Shielded

    m (ft)

    300 (984)

    300 (984)

    300 (984)

    300 (984)

    • Unshielded

    m (ft)

    450 (1476)

    450 (1476)

    450 (1476)

    450 (1476)

    Conformity

     

    CE

    CE

    CE

    CE

    Certificate of suitability

     

    cURus

    cURus

    cURus

    cURus

    dv/dt reactor

    Power loss, max. 2)

     

     

     

     

     

    • At 50 Hz 400 V

    kW

    0.701

    0.874

    1.106

    1.111

    • At 60 Hz 460 V

    kW

    0.729

    0.904

    1.115

    1.154

    • At 150 Hz 400 V

    kW

    0.78

    0.963

    1.226

    1.23

    Connections

     

     

     

     

     

    • To the Power Module/ Motor Module

     

    1 × hole for M10

    1 × hole for M12

    1 × hole for M12

    2 × hole for M12

    • To load

     

    1 × hole for M10

    1 × hole for M12

    1 × hole for M12

    2 × hole for M12

    • PE

     

    M6 screw

    M6 screw

    M6 screw

    M6 screw

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    410 (16.1)

    460 (18.1)

    460 (18.1)

    445 (17.5)

    • Height

    mm (in)

    370 (14.6)

    370 (14.6)

    385 (15.2)

    385 (15.2)

    • Depth

    mm (in)

    229 (9.02)

    275 (10.8)

    312 (12.3)

    312 (12.3)

    Weight, approx.

    kg (lb)

    66 (146)

    122 (269)

    149 (329)

    158 (348)

    Voltage Peak Limiter (VPL)

    Power loss, max.

     

     

     

     

     

    • At 50 Hz 400 V

    kW

    0.029

    0.042

    0.077

    0.134

    • At 60 Hz 460 V

    kW

    0.027

    0.039

    0.072

    0.125

    • At 150 Hz 400 V

    kW

    0.025

    0.036

    0.066

    0.114

    Connections

     

     

     

     

     

    • To dv/dt reactor

     

    M8 nut

    70 mm2 terminals

    1 × hole for M8

    1 × hole for M10

    • To DC link

     

    M8 nut

    70 mm2 terminals

    1 × hole for M8

    1 × hole for M10

    • PE

     

    M8 stud

    35 mm2 terminals

    M8 stud

    M8 stud

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    265 (10.4)

    392 (15.4)

    309 (12.2)

    309 (12.2)

    • Height

    mm (in)

    263 (10.3)

    285 (11.2)

    1313 (51.7)

    1313 (51.7)

    • Depth

    mm (in)

    190 (7.48)

    210 (8.27)

    400 (15.7)

    400 (15.7)

    Weight, approx.

    kg (lb)

    6 (13)

    16 (35)

    48 (106)

    72 (159)

    Suitable for Power Module

    (Type rating)

     

    6SL3310-1TE32-1AA3 (110 kW)

    6SL3315-1TE32-1AA3 (110 kW)

    6SL3310-1TE32-6AA3 (132 kW)

    6SL3315-1TE32-6AA3 (132 kW)

    6SL3310-1TE33-1AA3 (160 kW)

    6SL3315-1TE33-1AA3 (160 kW)

    6SL3310-1TE33-8AA3 (200 kW)

    6SL3310-1TE35-0AA3 (250 kW)

    6SL3315-1TE35-0AA3 (250 kW)

    Suitable for Motor Module

    (Type rating)

     

    6SL3320-1TE32-1AA3 (110 kW)

    6SL3325-1TE32-1AA3 (110 kW)

    6SL3320-1TE32-6AA3 (132 kW)

    6SL3325-1TE32-6AA3 (132 kW)

    6SL3320-1TE33-1AA3 (160 kW)

    6SL3325-1TE33-1AA3 (160 kW)

    6SL3320-1TE33-8AA3 (200 kW)

    6SL3320-1TE35-0AA3 (250 kW)

    6SL3325-1TE35-0AA3 (250 kW)

    6SL3320-1TE36-1AA3 (315 kW)

    6SL3325-1TE36-1AA0 (315 kW)

    6SL3320-1TE37-5AA0 (400 kW)

    6SL3325-1TE37-5AA0 (400 kW)

    6SL3320-1TE38-4AA0 (450 kW)

    6SL3325-1TE38-4AA0 (450 kW)

    6SL3320-1TE41-0AA3 (560 kW)

    6SL3325-1TE41-0AA3 (560 kW)

    6SL3320-1TE41-2AA3 (710 kW)

    6SL3325-1TE41-2AA3 (710 kW)

    6SL3320-1TE41-4AA3 (800 kW)

    6SL3325-1TE41-4AA3 (800 kW)

    6SL3325-1TE41-4AS3 (800 kW) 2)



    1) Longer cable lengths for specific configurations are available on request.

    2) This Motor Module has been specifically designed for loads demanding a high dynamic performance.

    Note:

    For powers above 560 kW (380 ... 480 V) or 710 kW (500 ... 690 V), then a filter contains two dv/dt reactors.
    The technical specifications listed refer to a dv/dt reactor.
    For additional information on dv/dt filters, please refer to the SINAMICS Low Voltage Engineering Manual.

    Line voltage 500 ... 690 V 3 AC

    dv/dt filter plus VPL

     

    6SL3000-2DH31-0AA0

    6SL3000-2DH31-5AA0

    6SL3000-2DH32-2AA0

    6SL3000-2DH33-3AA0

    Ith max

    A

    100

    150

    215

    330

    Degree of protection

     

    IP00

    IP00

    IP00

    IP00

    Cable length, max.

    between dv/dt filter and motor 1)

     

     

     

     

     

    • Shielded

    m (ft)

    300 (984)

    300 (984)

    300 (984)

    300 (984)

    • Unshielded

    m (ft)

    450 (1476)

    450 (1476)

    450 (1476)

    450 (1476)

    Conformity

     

    CE

    CE

    CE

    CE

    Certificate of suitability 2)

     

    cURus

    cURus

    cURus

    cURus

    dv/dt reactor

    Power loss, max.

     

     

     

     

     

    • At 50 Hz 500/690 V

    kW

    0.49

    0.389

    0.578

    0.595

    • At 60 Hz 575 V

    kW

    0.508

    0.408

    0.604

    0.62

    • At 150 Hz 500/690 V

    kW

    0.541

    0.436

    0.645

    0.661

    Connections

     

     

     

     

     

    • To the Power Module/ Motor Module

     

    1 × hole for M10

    1 × hole for M10

    1 × hole for M10

    1 × hole for M10

    • To load

     

    1 × hole for M10

    1 × hole for M10

    1 × hole for M10

    1 × hole for M10

    • PE

     

    M6 screw

    M6 screw

    M6 screw

    M6 screw

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    350 (13.8)

    350 (13.8)

    460 (18.1)

    460 (18.1)

    • Height

    mm (in)

    320 (12.6)

    320 (12.6)

    360 (14.2)

    360 (14.2)

    • Depth

    mm (in)

    227 (8.94)

    227 (8.94)

    275 (10.8)

    275 (10.8)

    Weight, approx.

    kg (lb)

    48 (106)

    50 (110)

    83 (183)

    135 (298)

    Voltage Peak Limiter (VPL)

    Power loss, max.

     

     

     

     

     

    • At 50 Hz 500/690 V

    kW

    0.016

    0.02

    0.032

    0.042

    • At 60 Hz 575 V

    kW

    0.015

    0.019

    0.03

    0.039

    • At 150 Hz 500/690 V

    kW

    0.013

    0.018

    0.027

    0.036

    Connections

     

     

     

     

     

    • To dv/dt reactor

     

    M8 nut

    M8 nut

    70 mm2 terminals

    70 mm2 terminals

    • To DC link

     

    M8 nut

    M8 nut

    70 mm2 terminals

    70 mm2 terminals

    • PE

     

    M8 stud

    M8 stud

    35 mm2 terminals

    35 mm2 terminals

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    263 (10.3)

    263 (10.3)

    392 (15.4)

    392 (15.4)

    • Height

    mm (in)

    265 (10.4)

    265 (10.4)

    285 (11.2)

    285 (11.2)

    • Depth

    mm (in)

    188 (7.40)

    188 (7.40)

    210 (8.27)

    210 (8.27)

    Weight, approx.

    kg (lb)

    6 (13)

    6 (13)

    16 (35)

    16 (35)

     

    Suitable for Motor Module

    (Type rating)

     

    6SL3320-1TG28-5AA3 (75 kW)

    6SL3320-1TG31-0AA3 (90 kW)

    6SL3325-1TG31-0AA3 (90 kW)

    6SL3320-1TG31-2AA3 (110 kW)

    6SL3320-1TG31-5AA3 (132 kW)

    6SL3325-1TG31-5AA3 (132 kW)

    6SL3320-1TG31-8AA3 (160 kW)

    6SL3320-1TG32-2AA3 (200 kW)

    6SL3325-1TG32-2AA3 (200 kW)

    6SL3320-1TG32-6AA3 (250 kW)

    6SL3320-1TG33-3AA3 (315 kW)

    6SL3325-1TG33-3AA3 (315 kW)



    1) Longer cable lengths for specific configurations are available on request.

    2) Only for line voltages 500 ... 600 V 3 AC.

    Note:

    For powers above 560 kW (380 ... 480 V) or 710 kW (500 ... 690 V), then a filter contains two dv/dt reactors.
    The technical specifications listed refer to a dv/dt reactor.
    For additional information on dv/dt filters, please refer to the SINAMICS Low Voltage Engineering Manual.

    Line voltage 500 ... 690 V 3 AC

    dv/dt filter plus VPL

     

    6SL3000-2DH34-1AA0

    6SL3000-2DH35-8AA0

    6SL3000-2DH38-1AA0

    6SL3000-2DH41-4AA0

    Ith max

    A

    410

    575

    810

    1270

    Degree of protection

     

    IP00

    IP00

    IP00

    IP00

    Cable length, max.

    between dv/dt filter and motor 1)

     

     

     

     

     

    • Shielded

    m (ft)

    300 (984)

    300 (984)

    300 (984)

    300 (984)

    • Unshielded

    m (ft)

    450 (1476)

    450 (1476)

    450 (1476)

    450 (1476)

    Conformity

     

    CE

    CE

    CE

    CE

    Certificate of suitability 2)

     

    cURus

    cURus

    cURus

    cURus

    dv/dt reactor

    Power loss, max.

     

     

     

     

     

    • At 50 Hz 500/690 V

    kW

    0.786

    0.862

    0.828

    0.865

    • At 60 Hz 575 V

    kW

    0.826

    0.902

    0.867

    0.904

    • At 150 Hz 500/690 V

    kW

    0.884

    0.964

    0.927

    0.966

    Connections

     

     

     

     

     

    • To the Power Module/ Motor Module

     

    1 × hole for M12

    1 × hole for M12

    2 × hole for M12

    2 × hole for M12

    • To load

     

    1 × hole for M12

    1 × hole for M12

    2 × hole for M12

    2 × hole for M12

    • PE

     

    M6 screw

    M6 screw

    M6 screw

    M6 screw

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    460 (18.1)

    460 (18.1)

    445 (17.5)

    445 (17.5)

    • Height

    mm (in)

    385 (15.2)

    385 (15.2)

    385 (15.2)

    385 (15.2)

    • Depth

    mm (in)

    312 (12.3)

    312 (12.3)

    312 (12.3)

    312 (12.3)

    Weight, approx.

    kg (lb)

    147 (324)

    172 (379)

    160 (353)

    164 (362)

    Voltage Peak Limiter (VPL)

    Power loss, max.

     

     

     

     

     

    • At 50 Hz 500/690 V

    kW

    0.051

    0.063

    0.106

    0.15

    • At 60 Hz 575 V

    kW

    0.048

    0.059

    0.1

    0.14

    • At 150 Hz 500/690 V

    kW

    0.043

    0.054

    0.091

    0.128

    Connections

     

     

     

     

     

    • To dv/dt reactor

     

    1 × hole for M8

    1 × hole for M8

    1 × hole for M10

    1 × hole for M10

    • To DC link

     

    1 × hole for M8

    1 × hole for M8

    1 × hole for M10

    1 × hole for M10

    • PE

     

    M8 stud

    M8 stud

    M8 stud

    M8 stud

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    309 (12.2)

    309 (12.2)

    309 (12.2)

    309 (12.2)

    • Height

    mm (in)

    1313 (51.7)

    1313 (51.7)

    1313 (51.7)

    1313 (51.7)

    • Depth

    mm (in)

    400 (15.7)

    400 (15.7)

    400 (15.7)

    400 (15.7)

    Weight, approx.

    kg (lb)

    48 (106)

    48 (106)

    72 (159)

    73 (161)

    Suitable for Motor Module

    (Type rating)

     

    6SL3320-1TG34-1AA3 (400 kW)

    6SL3320-1TG34-7AA3 (450 kW)

    6SL3325-1TG34-7AA3 (450 kW)

    6SL3320-1TG35-8AA3 (560 kW)

    6SL3325-1TG35-8AA3 (560 kW)

    6SL3320-1TG37-4AA3 (710 kW)

    6SL3325-1TG37-4AA3 (710 kW)

    6SL3320-1TG38-1AA3 (800 kW)

    6SL3325-1TG38-0AA3 (800 kW)

    6SL3325-1TG38-1AA3 (800 kW)

    6SL3320-1TG38-8AA3 (900 kW)

    6SL3320-1TG41-0AA3 (1000 kW)

    6SL3325-1TG41-0AA3 (1000 kW)

    6SL3320-1TG41-3AA3 (1200 kW)

    6SL3325-1TG41-3AA3 (1200 kW)



    1) Longer cable lengths for specific configurations are available on request.

    2) Only for line voltages 500 ... 600 V 3 AC.

    Note:

    For powers above 560 kW (380 ... 480 V) or 710 kW (500 ... 690 V), then a filter contains two dv/dt reactors.
    The technical specifications listed refer to a dv/dt reactor.
    For additional information on dv/dt filters, please refer to the SINAMICS Low Voltage Engineering Manual.