- Каталог оборудования Siemens
- Каталог продуктов Siemens Industry
- Приводная техника
- Преобразователи
- Стандартные преобразователи
- Общая информация о базовых преобразователях SINAMICS V
- Преобразователи частоты общего назначения SINAMICS G
- Высокопроизводительные преобразователи SINAMICS S
- Сервопреобразователь SINAMICS S110
- SINAMICS S120
- Excellence in Motion Control
- Системный обзор
- System data
- Модули контроля
- Сетевые модули и сетевые компоненты питания
- Модули двигателей
- SINAMICS S120 Chassis Format Units
- Air-cooled units
- Power Modules
- Active Line Modules
- Active Interface Modules
- Smart Line Modules
- Basic Line Modules
- Basic Line Modules
- Motor Modules
- Mounting device for power blocks
- Liquid-cooled units
- Power Modules
- Active Line Modules
- Active Interface Modules
- Basic Line Modules
- Motor Modules
- System components
- Line filters
- Line reactors
- Recommended line-side system components
- Braking Modules
- Braking resistors
- DC link fuses
- Motor reactors
- dv/dt filters plus VPL
- dv/dt filters compact plus VPL
- Sine-wave filters
- Safe Brake Adapter SBA
- Силовые модули
- Дополнительные системные компоненты
- Компоненты
- Кабели и штекеры MOTION-CONNECT
- Инструментальное программное обеспечение
- Safety Integrated
- Конфигурирование
- Сервис и документация
- Услуги и документация
- Приводная система SINAMICS S120
- Сертификация
- SIPLUS SINAMICS S120
- SINAMICS S120M distributed servo drive
- SINAMICS S120 Combi
- SINAMICS S120 Chassis Format Units
- SINAMICS S120 Cabinet Modules
- SINAMICS S150 converter cabinet units
- MICROMASTER
- SIPLUS POSMO A
- SIMODRIVE POSMO
- LOHER DYNAVERT Drive System
- Преобразователи на среднее напряжение
- Преобразователи постоянного тока
- Стандартные преобразователи
- Двигатели переменного тока
- Generators
- Мотор-редукторы
- Flender Gear Units
- Couplings
- Инструментальное программное обеспечение
- Дополнительные компоненты
- Преобразователи
- Техника автоматизации
- Energy
- Автоматизация и безопасность зданий
- Низковольтная коммутационная техника
- Технология безопасности
- Системные решения и продукты для отраслей
- Сервис
- Приводная техника
- Заказные данные (12)
- Аксессуары (1)
- Информационные материалы
Информационные материалы
Basic Line Modules are available for applications in which no energy is returned to the supply or where the energy exchange between motor and generator axes takes place in the DC link. Basic Line Modules are designed for connection to grounded TN/TT and non-grounded IT supply systems.
The Basic Line Modules are available in different frame sizes. With frame sizes FB and GB, a fully controlled thyristor bridge is used to pre-charge the Basic Line Modules and connected Motor Modules. The thyristors normally operate with a trigger delay angle of 0°.
Basic Line Modules, frame size GD for 900 kW (400 V) or 1500 kW (690 V) include a diode bridge, and the DC link is pre-charged via a separate line-side pre-charging circuit.
A Braking Module of the appropriate frame size can be integrated into a Basic Line Module in order to permit, in conjunction with an external braking resistor, regenerative operation of the drive system.
Дизайн
The Basic Line Modules have the following interfaces as standard:
- 1 line supply connection
- 1 connection for the 24 V DC electronics power supply
- 1 DC link connection (DCP, DCN) for supplying the connected Motor Modules
- 1 DC link connection (DCPA, DCNA) for connecting a Braking Module
- 3 DRIVE‑CLiQ sockets
- 1 temperature sensor input for KTY84‑130, Pt1000 or PTC (Pt1000 can be used from firmware V4.7 HF17)
- 1 PE connection
The status of the Basic Line Modules is indicated via three LEDs.
The scope of supply of the Basic Line Modules includes:
- DRIVE‑CLiQ cable to connect to a Control Unit
- DRIVE‑CLiQ cable to connect the Control Unit to the first Motor Module
- 1 set of warning labels in 30 languages
(BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, JP, KR, LT, LV, MT, NL, NO, PL, PT, RO, RU, SE, SI, SK, TR)
Pre-charging circuit for the Basic Line Modules, frame size GD
Unlike Basic Line Modules in frame sizes FB and GB, a Basic Line Module in frame size GD requires a separate precharging circuit. The pre-charging circuit components must be ordered separately.
During startup, the pre-charging circuit ensures that the DC link capacitors of the Basic Line Module and the connected Motor Modules are pre-charged with current limiting. After pre-charging has been completed, the circuit breaker is closed and the pre-charging circuit bypassed; the Basic Line Module is then directly connected to the line supply.
The pre-charging circuit comprises a pre-charging contactor and pre-charging resistors; the circuit must be protected against overcurrent using suitable protection measures. To increase the permissible DC link capacitance, the pre-charging resistors can also be connected in parallel in each phase.
More information on the pre-charging circuit is to be found in the SINAMICS Low Voltage Engineering Manual.
For components for the pre-charging circuit and for recommended line-side system components, see System components.
Интеграция
The Basic Line Modules communicate with the higher-level control module via DRIVE-CLiQ. The control module in this case can be a CU320-2 or a SIMOTION D Control Unit. An external 24 V DC power supply is required to operate Basic Line Modules.
Connection example of a Basic Line Module, frame sizes FB, GB
Connection example of a Basic Line Module, frame size GD
Технические данные
General technical specifications
Electrical specifications
Line power factor
at rated power
- Basic fundamental (cos φ1)
>0.96
- Total (λ)
0.75 ... 0.93
Efficiency
>99 %
DC link voltage, approx. 1)
1.35 × line voltage under partial load
1.32 × line voltage under full loadMain contactor control
- Terminal block -X9/5-6
240 V AC, max. 8 A
30 V DC, max. 1 A1) The DC link voltage is unregulated and load-dependent. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
Line voltage 380 ... 480 V 3 AC
Basic Line Modules
6SL3330-1TE34-2AA3
6SL3330-1TE35-3AA3
6SL3330-1TE38-2AA3
6SL3330-1TE41-2AA3
6SL3330-1TE41-5AA3
6SL3330-1TE41-8AA3
Rated power
- At Irated DC (50 Hz 400 V)
kW
200
250
400
560
710
900
- At IH DC (50 Hz 400 V)
kW
160
200
315
450
560
705
- At Irated DC (60 Hz 460 V)
hp
305
385
615
860
1090
1390
- At IH DC (60 Hz 460 V)
hp
245
305
485
690
860
1090
DC link current
- Rated current Irated DC
A
420
530
820
1200
1500
1880
- Base-load current IH DC 1)
A
328
413
640
936
1170
1467
- Maximum current Imax DC
A
630
795
1230
1800
2250
2820
Input current
- Rated current Irated I
A
365
460
710
1010
1265
1630
- Maximum current Imax I
A
547
690
1065
1515
1897
2380
• Max. pre-charging current (max. 3 s)
A
Internal
Internal
Internal
Internal
Internal
308
Current demand
- 24 V DC auxiliary power supply
A
1.1
1.1
1.1
1.1
1.1
1.1
DC link capacitance
- Basic Line Module
μF
7200
9600
14600
23200
29000
34800
- Drive line-up, max.
μF
57600
76800
116800
185600
232000
139200/278400 2)
Power loss, max. 3)
- At 50 Hz 400 V
kW
1.9
2.1
3.2
4.6
5.5
6.9
- At 60 Hz 460 V
kW
1.9
2.1
3.2
4.6
5.5
6.9
Cooling air requirement
m3/s (ft3/s)
0.17 (6.00)
0.17 (6.00)
0.17 (6.00)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
66/68
66/68
66/68
71/73
71/73
71/73
Line connection
U1, V1, W1
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M12 screw
Flat connector for M12 screw
Flat connector for M12 screw
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
2 × 240
6 × 185
6 × 185
6 × 185
DC link connection
DCP, DCN
M10 screw
M10 screw
M10 screw
3 × hole for M12
3 × hole for M12
3 × hole for M12
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
2 × 240
6 × 185
6 × 185
6 × 185
PE/GND connection
2 × hole for M10
2 × hole for M10
2 × hole for M10
2 × hole for M12
2 × hole for M12
2 × hole for M12
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
2 × 240
4 × 240
4 × 240
4 × 240
Cable length, max. 4)
- Shielded
m (ft)
2600 (8531)
2600 (8531)
2600 (8531)
4000 (13124)
4000 (13124)
4800 (15749)
- Unshielded
m (ft)
3900 (12796)
3900 (12796)
3900 (12796)
6000 (19686)
6000 (19686)
7200 (23623)
Degree of protection
IP00
IP00
IP00
IP00
IP00
IP00
Dimensions
- Width
mm (in)
310 (12.2)
310 (12.2)
310 (12.2)
310 (12.2)
310 (12.2)
310 (12.2)
- Height
mm (in)
1164 (45.8)
1164 (45.8)
1164 (45.8)
1653 (65.1)
1653 (65.1)
1653 (65.1)
- Depth
mm (in)
352 (13.9)
352 (13.9)
352 (13.9)
550 (21.6)
550 (21.6)
550 (21.6)
Weight, approx.
kg (lb)
96 (212)
96 (212)
96 (212)
214 (472)
214 (472)
214 (472)
Frame size
FB
FB
FB
GB
GB
GD
Minimum short-circuit current 5)
A
4400
5200
10000
12400
18400
18600
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.
2) The first value applies for one precharging resistor for each phase, the second value for two precharging resistors connected in parallel for each phase.
3) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.
4) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
5) Current required for reliably triggering protective devices.
Line voltage 500 ... 690 V 3 AC
Basic Line Modules
6SL3330-1TG33-0AA3
6SL3330-1TG34-3AA3
6SL3330-1TG36-8AA3
6SL3330-1TG41-1AA3
6SL3330-1TG41-4AA3
6SL3330-1TG41-8AA3
Rated power
- At Irated DC (50 Hz 690 V)
kW
250
355
560
900
1100
1500
- At IH DC (50 Hz 690 V)
kW
195
280
440
710
910
1220
- At Irated DC (50 Hz 500 V)
kW
175
250
390
635
810
1085
- At IH DC (50 Hz 500 V)
kW
165
235
365
595
755
1015
- At Irated DC (60 Hz 575 V)
hp
250
350
600
900
1250
1500
- At IH DC (60 Hz 575 V)
hp
200
300
450
800
1000
1250
DC link current
- Rated current Irated DC
A
300
430
680
1100
1400
1880
- Base-load current IH DC 1)
A
234
335
530
858
1092
1467
- Maximum current Imax DC
A
450
645
1020
1650
2100
2820
Input current
- Rated current Irated I
A
260
375
575
925
1180
1580
- Maximum current Imax I
A
390
563
863
1388
1770
2370
- Max. pre-charging current (max. 3 s)
A
Internal
Internal
Internal
Internal
Internal
234
Current demand
- 24 V DC auxiliary power supply
A
1.1
1.1
1.1
1.1
1.1
1.1
DC link capacitance
- Basic Line Module
μF
3200
4800
7300
11600
15470
19500
- Drive line-up, max.
μF
25600
38400
58400
92800
123760
78000/156000 2)
Power loss, max. 3)
- At 50 Hz 690 V
kW
1.5
2.1
3.0
5.4
5.8
7.3
- At 60 Hz 575 V
kW
1.5
2.1
3.0
5.4
5.8
7.3
Cooling air requirement
m3/s (ft3/s)
0.17 (6.00)
0.17 (6.00)
0.17 (6.00)
0.36 (12.7)
0.36 (12.7)
0.36 (12.7)
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
66/68
66/68
66/68
71/73
71/73
71/73
Line connection
U1, V1, W1
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M12 screw
Flat connector for M12 screw
Flat connector for M12 screw
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
2 × 240
6 × 185
6 × 185
6 × 185
DC link connection
DCP, DCN
M10 screw
M10 screw
M10 screw
3 × hole for M12
3 × hole for M12
3 × hole for M12
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
2 × 240
6 ×185
6 × 185
6 × 185
PE/GND connection
2 × hole for M10
2 × hole for M10
2 × hole for M10
2 × hole for M12
2 × hole for M12
2 × hole for M12
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
2 × 240
4 × 240
4 × 240
4 × 240
Cable length, max. 4)
- Shielded
m (ft)
1500 (4921)
1500 (4921)
1500 (4921)
2250 (7382)
2250 (7382)
2750 (9023)
- Unshielded
m (ft)
2250 (7382)
2250 (7382)
2250 (7382)
3375 (11073)
3375 (11073)
4125 (13534)
Degree of protection
IP00
IP00
IP00
IP00
IP00
IP00
Dimensions
- Width
mm (in)
310 (12.2)
310 (12.2)
310 (12.2)
310 (12.2)
310 (12.2)
310 (12.2)
- Height
mm (in)
1164 (45.8)
1164 (45.8)
1164 (45.8)
1653 (65.1)
1653 (65.1)
1653 (65.1)
- Depth
mm (in)
352 (13.9)
352 (13.9)
352 (13.9)
550 (21.6)
550 (21.6)
550 (21.6)
Weight, approx.
kg (lb)
96 (212)
96 (212)
96 (212)
214 (472)
214 (472)
214 (472)
Frame size
FB
FB
FB
GB
GB
GD
Minimum short-circuit current 5)
A
3000
4400
8000
10400
16000
18600
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.
2) The first value applies for one pre-charging resistor for each phase, the second value for two precharging resistors connected in parallel for each phase.
3) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.
4) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
5) Current required for reliably triggering protective devices.