    Smart Line Modules are infeed/regenerative feedback units that supply power to connected Motor Modules. Furthermore, they are capable of feeding regenerative energy back into the grid. The infeed occurs over a diode jumper, while stable, line-commutated regenerative feedback takes place via IGBTs with 100 % continuous energy regeneration. The regenerative capability of the modules can be deactivated by means of parameterization.

    Smart Line Modules are designed for connection to grounded TN/TT and non-grounded IT supply systems.

    The DC link is pre-charged by means of integrated pre-charging resistors.

    To operate the Smart Line Module, the associated line reactor or a suitable transformer is required.

    Дизайн

    The Smart Line Modules have the following interfaces as standard:

    • 1 line supply connection
    • 1 connection for the 24 V DC electronics power supply
    • 1 DC link connection (DCP, DCN) for supplying the connected Motor Modules
    • 1 DC link connection (DCPA, DCNA) for connecting a Braking Module
    • 3 DRIVE-CLiQ sockets
    • 1 temperature sensor input for KTY84‑130, Pt1000, PTC or Pt100 (Pt1000 can be used from firmware V4.7 HF17)
    • 1 PE/protective conductor connection (2 connections for sizes HX and JX)

    The status of the Smart Line Modules is indicated via three LEDs.

    The scope of supply of the Smart Line Modules includes:

    • DRIVE-CLiQ cable to connect to a Control Unit
    • DRIVE-CLiQ cable for connection between the Control Unit and first Motor Module (type dependent)
    • 1 set of warning labels in 30 languages
      (BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, JP, KR, LT, LV, MT, NL, NO, PL, PT, RO, RU, SE, SI, SK, TR)

    Интеграция

    The Smart Line Modules communicate with the higher-level control module via DRIVE-CLiQ. The control module in this case can be a CU320-2 or a SIMOTION D Control Unit. An external 24 V DC power supply is required to operate the Smart Line Modules.

    Connection example of a Smart Line Module

    Технические данные

    General technical specifications

    Electrical specifications

    Line power factor
    at rated power

     

    • Basic fundamental (cos φ1)

    >0.96

    • Total (λ)

    0.75 ... 0.93

    Efficiency

    >98.5 %

    DC link voltage, approx. 1)

    1.32 × line voltage under partial load
    1.30 × line voltage under full load

    Main contactor control

     

    • Terminal block -X9/5-6

    240 V AC, max. 8 A
    30 V DC, max. 1 A



    1) The DC link voltage is unregulated and load-dependent. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

    Line voltage 380 ... 480 V 3 AC

    Smart Line Modules

     

    6SL3330-6TE35-5AA3

    6SL3330-6TE37-3AA3

    6SL3330-6TE41-1AA3

    6SL3330-6TE41-3AA3

    6SL3330-6TE41-7AA3

    Rated power

     

     

     

     

     

     

    • At Irated DC (50 Hz 400 V)

    kW

    250

    355

    500

    630

    800

    • At IH DC (50 Hz 400 V)

    kW

    235

    315

    450

    555

    730

    • At Irated DC (60 Hz 460 V)

    hp

    385

    545

    770

    970

    1230

    • At IH DC (60 Hz 460 V)

    hp

    360

    485

    695

    855

    1125

    DC link current

     

     

     

     

     

     

    • Rated current Irated DC

    A

    550

    730

    1050

    1300

    1700

    • Base-load current IH DC 1)

    A

    490

    650

    934

    1157

    1513

    • Maximum current Imax DC

    A

    825

    1095

    1575

    1950

    2550

    Infeed/regenerative feedback current

     

     

     

     

     

     

    • Rated current Irated I

    A

    463

    614

    883

    1093

    1430

    • Maximum current Imax I

    A

    694

    921

    1324

    1639

    2145

    Current demand

     

     

     

     

     

     

    • 24 V DC auxiliary power supply

    A

    1.35

    1.35

    1.4

    1.5

    1.7

    • 400 V AC

    A

    1.8

    1.8

    3.6

    5.4

    5.4

    DC link capacitance

     

     

     

     

     

     

    • Smart Line Module

    μF

    8400

    12000

    16800

    18900

    28800

    • Drive line-up, max.

    μF

    42000

    60000

    67200

    75600

    115200

    Power loss, max. 2)

     

     

     

     

     

     

    • At 50 Hz 400 V

    kW

    3.7

    4.7

    7.1

    11.0

    11.5

    • At 60 Hz 460 V

    kW

    3.7

    4.7

    7.1

    11.0

    11.5

    Cooling air requirement

    m3/s (ft3/s)

    0.36 (12.7)

    0.36 (12.7)

    0.78 (27.5)

    1.08 (38.1)

    1.08 (38.1)

    Sound pressure level LpA

    (1 m) at 50/60 Hz

    dB

    69/73

    69/73

    70/73

    70/73

    70/73

    Line connection

    U1, V1, W1

     

    Flat connector for M10 screw

    Flat connector for M10 screw

    Flat connector for M12 screw

    Flat connector for M12 screw

    Flat connector for M12 screw

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    2 × 240

    4 × 240

    6 × 240

    6 × 240

    DC link connection

    DCP, DCN

     

    M10 screw

    M10 screw

    4 × hole for M12

    4 × hole for M12

    4 × hole for M12

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    2 × 240

    Busbar

    Busbar

    Busbar

    PE/GND connection

     

    Hole for M10

    Hole for M10

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    2 × 240

    PE1/GND connection

     

    M12 screw

    M12 screw

    M12 screw

    • Conductor cross section, max. (IEC)

    mm2

    240

    240

    240

    PE2/GND connection

     

    2 × M12 screw

    2 × M12 screw

    2 × M12 screw

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    2 × 240

    2 × 240

    Cable length, max. 3)

     

     

     

     

     

     

    • Shielded

    m (ft)

    4000 (13124)

    4000 (13124)

    4800 (15749)

    4800 (15749)

    4800 (15749)

    • Unshielded

    m (ft)

    6000 (19686)

    6000 (19686)

    7200 (23623)

    7200 (23623)

    7200 (23623)

    Degree of protection

     

    IP00

    IP00

    IP00

    IP00

    IP00

    Dimensions

     

     

     

     

     

     

    • Width

    mm (in)

    310 (12.2)

    310 (12.2)

    503 (19.8)

    704 (27.7)

    704 (27.7)

    • Height

    mm (in)

    1413 (55.6)

    1413 (55.6)

    1475 (58.1)

    1480 (58.3)

    1480 (58.3)

    • Depth

    mm (in)

    550 (21.6)

    550 (21.6)

    548 (21.6)

    550 (21.6)

    550 (21.6)

    Weight, approx.

    kg (lb)

    150 (331)

    150 (331)

    294 (648)

    458 (1010)

    458 (1010)

    Frame size

     

    GX

    GX

    HX

    JX

    JX

    Minimum short-circuit current 4)

    A

    6200

    9200

    10400

    16000

    21000



    1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.

    2) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.

    3) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

    4) Current required for reliably triggering protective devices.

    Line voltage 500 ... 690 V 3 AC

    Smart Line Modules

     

    6SL3330-6TG35-5AA3

    6SL3330-6TG38-8AA3

    6SL3330-6TG41-2AA3

    6SL3330-6TG41-7AA3

    Rated power

     

     

     

     

     

    • At Irated DC (50 Hz 690 V)

    kW

    450

    710

    1000

    1400

    • At IH DC (50 Hz 690 V)

    kW

    405

    665

    885

    1255

    • At Irated DC (50 Hz 500 V)

    kW

    320

    525

    705

    995

    • At IH DC (50 Hz 500 V)

    kW

    295

    480

    640

    910

    • At Irated DC (60 Hz 575 V)

    hp

    500

    790

    1115

    1465

    • At IH DC (60 Hz 575 V)

    hp

    450

    740

    990

    1400

    DC link current

     

     

     

     

     

    • Rated current Irated DC

    A

    550

    900

    1200

    1700

    • Base-load current IH DC 1)

    A

    490

    800

    1068

    1513

    • Maximum current Imax DC

    A

    825

    1350

    1800

    2550

    Infeed/regenerative feedback current

     

     

     

     

     

    • Rated current Irated I

    A

    463

    757

    1009

    1430

    • Maximum current Imax I

    A

    694

    1135

    1513

    2145

    Current demand

     

     

     

     

     

    • 24 V DC auxiliary power supply

    A

    1.35

    1.4

    1.5

    1.7

    • 500 V AC

    A

    1.3

    2.9

    4.3

    4.3

    • 690 V AC

    A

    0.94

    2.1

    3.1

    3.1

    DC link capacitance

     

     

     

     

     

    • Smart Line Module

    μF

    5600

    7400

    11100

    14400

    • Drive line-up, max.

    μF

    28000

    29600

    44400

    57600

    Power loss, max. 2)

     

     

     

     

     

    • At 50 Hz 690 V

    kW

    4.3

    6.5

    12.0

    13.8

    • At 60 Hz 575 V

    kW

    4.3

    6.5

    12.0

    13.8

    Cooling air requirement

    m3/s (ft3/s)

    0.36 (12.7)

    0.78 (27.5)

    1.08 (38.1)

    1.08 (38.1)

    Sound pressure level LpA

    (1 m) at 50/60 Hz

    dB

    69/73

    70/73

    70/73

    70/73

    Line connection

    U1, V1, W1

     

    Flat connector for M10 screw

    Flat connector for M12 screw

    Flat connector for M12 screw

    Flat connector for M12 screw

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    4 × 240

    6 × 240

    6 × 240

    DC link connection

    DCP, DCN

     

    M10 screw

    4 × hole for M12

    4 × hole for M12

    4 × hole for M12

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    Busbar

    Busbar

    Busbar

    PE connection

     

    Hole for M10

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    PE1/GND connection

     

    M12 screw

    M12 screw

    M12 screw

    • Conductor cross section, max. (IEC)

    mm2

    240

    240

    240

    PE2/GND connection

     

    2 × M12 screw

    2 × M12 screw

    2 × M12 screw

    • Conductor cross section, max. (IEC)

    mm2

    2 × 240

    2 × 240

    2 × 240

    Cable length, max. 3)

     

     

     

     

     

    • Shielded

    m (ft)

    2250 (7382)

    2750 (9023)

    2750 (9023)

    2750 (9023)

    • Unshielded

    m (ft)

    3375 (11073)

    4125 (13534)

    4125 (13534)

    4125 (13534)

    Degree of protection

     

    IP00

    IP00

    IP00

    IP00

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    310 (12.2)

    503 (19.8)

    704 (27.7)

    704 (27.7)

    • Height

    mm (in)

    1413 (55.6)

    1475 (58.1)

    1480 (58.3)

    1480 (58.3)

    • Depth

    mm (in)

    550 (21.6)

    548 (21.6)

    550 (21.6)

    550 (21.6)

    Weight, approx.

    kg (lb)

    150 (331)

    294 (648)

    458 (1010)

    458 (1010)

    Frame size

     

    GX

    HX

    JX

    JX

    Minimum short-circuit current 4)

    A

    6200

    10500

    12400

    21000



    1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.

    2) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.

    3) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

    4) Current required for reliably triggering protective devices.