- Каталог оборудования Siemens
- Каталог продуктов Siemens Industry
- Приводная техника
- Преобразователи
- Стандартные преобразователи
- Общая информация о базовых преобразователях SINAMICS V
- Преобразователи частоты общего назначения SINAMICS G
- Высокопроизводительные преобразователи SINAMICS S
- Сервопреобразователь SINAMICS S110
- SINAMICS S120
- Excellence in Motion Control
- Системный обзор
- System data
- Модули контроля
- Сетевые модули и сетевые компоненты питания
- Модули двигателей
- SINAMICS S120 Chassis Format Units
- Air-cooled units
- Power Modules
- Active Line Modules
- Active Interface Modules
- Smart Line Modules
- Smart Line Modules
- Basic Line Modules
- Motor Modules
- Mounting device for power blocks
- Liquid-cooled units
- Power Modules
- Active Line Modules
- Active Interface Modules
- Basic Line Modules
- Motor Modules
- System components
- Line filters
- Line reactors
- Recommended line-side system components
- Braking Modules
- Braking resistors
- DC link fuses
- Motor reactors
- dv/dt filters plus VPL
- dv/dt filters compact plus VPL
- Sine-wave filters
- Safe Brake Adapter SBA
- Силовые модули
- Дополнительные системные компоненты
- Компоненты
- Кабели и штекеры MOTION-CONNECT
- Инструментальное программное обеспечение
- Safety Integrated
- Конфигурирование
- Сервис и документация
- Услуги и документация
- Приводная система SINAMICS S120
- Сертификация
- SIPLUS SINAMICS S120
- SINAMICS S120M distributed servo drive
- SINAMICS S120 Combi
- SINAMICS S120 Chassis Format Units
- SINAMICS S120 Cabinet Modules
- SINAMICS S150 converter cabinet units
- MICROMASTER
- SIPLUS POSMO A
- SIMODRIVE POSMO
- LOHER DYNAVERT Drive System
- Преобразователи на среднее напряжение
- Преобразователи постоянного тока
- Стандартные преобразователи
- Двигатели переменного тока
- Generators
- Мотор-редукторы
- Flender Gear Units
- Couplings
- Инструментальное программное обеспечение
- Дополнительные компоненты
- Преобразователи
- Техника автоматизации
- Energy
- Автоматизация и безопасность зданий
- Низковольтная коммутационная техника
- Технология безопасности
- Системные решения и продукты для отраслей
- Сервис
- Приводная техника
- Заказные данные (9)
- Аксессуары (1)
- Информационные материалы
Информационные материалы
Smart Line Modules are infeed/regenerative feedback units that supply power to connected Motor Modules. Furthermore, they are capable of feeding regenerative energy back into the grid. The infeed occurs over a diode jumper, while stable, line-commutated regenerative feedback takes place via IGBTs with 100 % continuous energy regeneration. The regenerative capability of the modules can be deactivated by means of parameterization.
Smart Line Modules are designed for connection to grounded TN/TT and non-grounded IT supply systems.
The DC link is pre-charged by means of integrated pre-charging resistors.
To operate the Smart Line Module, the associated line reactor or a suitable transformer is required.
Дизайн
The Smart Line Modules have the following interfaces as standard:
- 1 line supply connection
- 1 connection for the 24 V DC electronics power supply
- 1 DC link connection (DCP, DCN) for supplying the connected Motor Modules
- 1 DC link connection (DCPA, DCNA) for connecting a Braking Module
- 3 DRIVE-CLiQ sockets
- 1 temperature sensor input for KTY84‑130, Pt1000, PTC or Pt100 (Pt1000 can be used from firmware V4.7 HF17)
- 1 PE/protective conductor connection (2 connections for sizes HX and JX)
The status of the Smart Line Modules is indicated via three LEDs.
The scope of supply of the Smart Line Modules includes:
- DRIVE-CLiQ cable to connect to a Control Unit
- DRIVE-CLiQ cable for connection between the Control Unit and first Motor Module (type dependent)
- 1 set of warning labels in 30 languages
(BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, JP, KR, LT, LV, MT, NL, NO, PL, PT, RO, RU, SE, SI, SK, TR)
Интеграция
The Smart Line Modules communicate with the higher-level control module via DRIVE-CLiQ. The control module in this case can be a CU320-2 or a SIMOTION D Control Unit. An external 24 V DC power supply is required to operate the Smart Line Modules.
Connection example of a Smart Line Module
Технические данные
General technical specifications
Electrical specifications
Line power factor
at rated power- Basic fundamental (cos φ1)
>0.96
- Total (λ)
0.75 ... 0.93
Efficiency
>98.5 %
DC link voltage, approx. 1)
1.32 × line voltage under partial load
1.30 × line voltage under full loadMain contactor control
- Terminal block -X9/5-6
240 V AC, max. 8 A
30 V DC, max. 1 A1) The DC link voltage is unregulated and load-dependent. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
Line voltage 380 ... 480 V 3 AC
Smart Line Modules
6SL3330-6TE35-5AA3
6SL3330-6TE37-3AA3
6SL3330-6TE41-1AA3
6SL3330-6TE41-3AA3
6SL3330-6TE41-7AA3
Rated power
- At Irated DC (50 Hz 400 V)
kW
250
355
500
630
800
- At IH DC (50 Hz 400 V)
kW
235
315
450
555
730
- At Irated DC (60 Hz 460 V)
hp
385
545
770
970
1230
- At IH DC (60 Hz 460 V)
hp
360
485
695
855
1125
DC link current
- Rated current Irated DC
A
550
730
1050
1300
1700
- Base-load current IH DC 1)
A
490
650
934
1157
1513
- Maximum current Imax DC
A
825
1095
1575
1950
2550
Infeed/regenerative feedback current
- Rated current Irated I
A
463
614
883
1093
1430
- Maximum current Imax I
A
694
921
1324
1639
2145
Current demand
- 24 V DC auxiliary power supply
A
1.35
1.35
1.4
1.5
1.7
- 400 V AC
A
1.8
1.8
3.6
5.4
5.4
DC link capacitance
- Smart Line Module
μF
8400
12000
16800
18900
28800
- Drive line-up, max.
μF
42000
60000
67200
75600
115200
Power loss, max. 2)
- At 50 Hz 400 V
kW
3.7
4.7
7.1
11.0
11.5
- At 60 Hz 460 V
kW
3.7
4.7
7.1
11.0
11.5
Cooling air requirement
m3/s (ft3/s)
0.36 (12.7)
0.36 (12.7)
0.78 (27.5)
1.08 (38.1)
1.08 (38.1)
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
69/73
69/73
70/73
70/73
70/73
Line connection
U1, V1, W1
Flat connector for M10 screw
Flat connector for M10 screw
Flat connector for M12 screw
Flat connector for M12 screw
Flat connector for M12 screw
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
4 × 240
6 × 240
6 × 240
DC link connection
DCP, DCN
M10 screw
M10 screw
4 × hole for M12
4 × hole for M12
4 × hole for M12
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
Busbar
Busbar
Busbar
PE/GND connection
Hole for M10
Hole for M10
–
–
–
- Conductor cross section, max. (IEC)
mm2
2 × 240
2 × 240
–
–
–
PE1/GND connection
–
–
M12 screw
M12 screw
M12 screw
- Conductor cross section, max. (IEC)
mm2
–
–
240
240
240
PE2/GND connection
–
–
2 × M12 screw
2 × M12 screw
2 × M12 screw
- Conductor cross section, max. (IEC)
mm2
–
–
2 × 240
2 × 240
2 × 240
Cable length, max. 3)
- Shielded
m (ft)
4000 (13124)
4000 (13124)
4800 (15749)
4800 (15749)
4800 (15749)
- Unshielded
m (ft)
6000 (19686)
6000 (19686)
7200 (23623)
7200 (23623)
7200 (23623)
Degree of protection
IP00
IP00
IP00
IP00
IP00
Dimensions
- Width
mm (in)
310 (12.2)
310 (12.2)
503 (19.8)
704 (27.7)
704 (27.7)
- Height
mm (in)
1413 (55.6)
1413 (55.6)
1475 (58.1)
1480 (58.3)
1480 (58.3)
- Depth
mm (in)
550 (21.6)
550 (21.6)
548 (21.6)
550 (21.6)
550 (21.6)
Weight, approx.
kg (lb)
150 (331)
150 (331)
294 (648)
458 (1010)
458 (1010)
Frame size
GX
GX
HX
JX
JX
Minimum short-circuit current 4)
A
6200
9200
10400
16000
21000
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.
2) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.
3) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
4) Current required for reliably triggering protective devices.
Line voltage 500 ... 690 V 3 AC
Smart Line Modules
6SL3330-6TG35-5AA3
6SL3330-6TG38-8AA3
6SL3330-6TG41-2AA3
6SL3330-6TG41-7AA3
Rated power
- At Irated DC (50 Hz 690 V)
kW
450
710
1000
1400
- At IH DC (50 Hz 690 V)
kW
405
665
885
1255
- At Irated DC (50 Hz 500 V)
kW
320
525
705
995
- At IH DC (50 Hz 500 V)
kW
295
480
640
910
- At Irated DC (60 Hz 575 V)
hp
500
790
1115
1465
- At IH DC (60 Hz 575 V)
hp
450
740
990
1400
DC link current
- Rated current Irated DC
A
550
900
1200
1700
- Base-load current IH DC 1)
A
490
800
1068
1513
- Maximum current Imax DC
A
825
1350
1800
2550
Infeed/regenerative feedback current
- Rated current Irated I
A
463
757
1009
1430
- Maximum current Imax I
A
694
1135
1513
2145
Current demand
- 24 V DC auxiliary power supply
A
1.35
1.4
1.5
1.7
- 500 V AC
A
1.3
2.9
4.3
4.3
- 690 V AC
A
0.94
2.1
3.1
3.1
DC link capacitance
- Smart Line Module
μF
5600
7400
11100
14400
- Drive line-up, max.
μF
28000
29600
44400
57600
Power loss, max. 2)
- At 50 Hz 690 V
kW
4.3
6.5
12.0
13.8
- At 60 Hz 575 V
kW
4.3
6.5
12.0
13.8
Cooling air requirement
m3/s (ft3/s)
0.36 (12.7)
0.78 (27.5)
1.08 (38.1)
1.08 (38.1)
Sound pressure level LpA
(1 m) at 50/60 Hz
dB
69/73
70/73
70/73
70/73
Line connection
U1, V1, W1
Flat connector for M10 screw
Flat connector for M12 screw
Flat connector for M12 screw
Flat connector for M12 screw
- Conductor cross section, max. (IEC)
mm2
2 × 240
4 × 240
6 × 240
6 × 240
DC link connection
DCP, DCN
M10 screw
4 × hole for M12
4 × hole for M12
4 × hole for M12
- Conductor cross section, max. (IEC)
mm2
2 × 240
Busbar
Busbar
Busbar
PE connection
Hole for M10
–
–
–
- Conductor cross section, max. (IEC)
mm2
2 × 240
–
–
–
PE1/GND connection
–
M12 screw
M12 screw
M12 screw
- Conductor cross section, max. (IEC)
mm2
–
240
240
240
PE2/GND connection
–
2 × M12 screw
2 × M12 screw
2 × M12 screw
- Conductor cross section, max. (IEC)
mm2
–
2 × 240
2 × 240
2 × 240
Cable length, max. 3)
- Shielded
m (ft)
2250 (7382)
2750 (9023)
2750 (9023)
2750 (9023)
- Unshielded
m (ft)
3375 (11073)
4125 (13534)
4125 (13534)
4125 (13534)
Degree of protection
IP00
IP00
IP00
IP00
Dimensions
- Width
mm (in)
310 (12.2)
503 (19.8)
704 (27.7)
704 (27.7)
- Height
mm (in)
1413 (55.6)
1475 (58.1)
1480 (58.3)
1480 (58.3)
- Depth
mm (in)
550 (21.6)
548 (21.6)
550 (21.6)
550 (21.6)
Weight, approx.
kg (lb)
150 (331)
294 (648)
458 (1010)
458 (1010)
Frame size
GX
HX
JX
JX
Minimum short-circuit current 4)
A
6200
10500
12400
21000
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.
2) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.
3) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.
4) Current required for reliably triggering protective devices.