Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SINAMICS G110M distributed frequency inverters

  • Информационные материалы

    Информационные материалы

    The SINAMICS G110M distributed frequency inverters are the solution for drive tasks in which a motor integrated frequency inverter is required. With different device versions (frame sizes FSA to FSB) in a power range from 0.37 kW to 4 kW (0.5 hp to 5 hp), the SINAMICS G110M is suitable for a wide variety of drive solutions. SINAMICS G110M supports continuous speed control of three-phase asynchronous motors and fulfills all the requirements of conveyor system applications from simple speed control through to demanding sensorless vector control. It can be integrated seamlessly into the system thanks to its compact design in IP65/IP66 degree of protection.

    Through the integrated functions such as quick stop and the limit switch function, the SINAMICS G110M is particularly suited for conveyor system applications.

    For applications that require safety engineering, the SINAMICS G110M has the integrated STO (Safe Torque Off 1)) function, which can be implemented without further external components. Integration via PROFIBUS, PROFINET, AS-Interface or USS into a higher-level SIMATIC controller is very easy thanks to complete TIA Portal integration 1) – one tool and one operating and data storage concept.

    SINAMICS G110M CU240M PN Control Unit, cable gland and PM240M Power Module FSA 1.5 kW (2 hp)

    SINAMICS G110M CU240M PN Control Unit, plug-in and PM240M Power Module FSA 1.5 kW (2 hp)

    Reasons for using distributed drive systems
    • Modular drive solutions – therefore standardized mechatronic elements that can be individually tested
    • No need for a cabinet, resulting in a smaller space requirement and less cooling
    • Long cables between the inverter and motor can be avoided (which means lower power losses, reduced interference emission and lower costs for shielded cables and additional filters)
    • Considerable benefits for conveyor systems with their extensive coverage (e.g. in the automotive and logistics industries)
    Siemens family of distributed drives

    Siemens offers an innovative portfolio of frequency inverters to optimally implement distributed drive solutions. The strengths of the individual members of the drive family permit simple adaptation to the widest range of application demands:

    • Identical connection systems
    • Standard commissioning and configuration tools

    Products from the family of distributed drives:

    • SINAMICS G110M frequency inverters
    • SINAMICS G110D frequency inverters
    • SINAMICS G120D frequency inverters
    • SIMATIC ET 200pro FC-2 frequency converters
    • SIRIUS M200D motor starters
    Modularity

    SINAMICS G110M is a modular, motor integrated inverter system with IP65/66 degree of protection comprising various function units. The main units are:

    • Control Unit (CU)
    • Power Module (PM)

    The Control Unit controls and monitors the Power Module and the connected motor using several different closed-loop control types that can be selected. The digital and analog inputs and digital outputs on the device support the simple wiring of sensors and actuators directly at the drive. The input signals can either be directly linked within the Control Unit and initiate local responses independently or they can be transferred to the central control via PROFIBUS, PROFINET or AS-Interface for further processing within the context of the overall plant.

    The Power Module supplies the motor in a performance range from 0.37 kW to 4 kW (0.5 hp to 5 hp). The Power Module is controlled by a microprocessor in the Control Unit. State-of-the-art IGBT technology with pulse width modulation is used for highly reliable and flexible motor operation. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor. The latest technical documentation (catalogs, dimensional drawings, certificates, manuals and operating instructions) is available on the Internet at the following address:

    http://www.siemens.com/sinamics-g110m

    and offline in the DT Configurator integrated in Catalog CA 01 as an add-on on DVD‑ROM. In addition, the DT Configurator can now be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address:

    http://www.siemens.com/dt-configurator

    Safety Integrated

    The distributed SINAMICS G110M inverters are already equipped with the integrated STO safety function (Safe Torque Off 1), certified in accordance with IEC 61508 SIL 2 as well as EN ISO 13849‑1 PL d and Category 3). It can be activated either over PROFIsafe or over the safety input.

    Additional information is provided in chapter Highlights, section Safety Integrated.

    STARTER commissioning tool

    The STARTER commissioning tool (V4.3 SP3 and higher) supports the commissioning and maintenance of SINAMICS G110M inverters 2). The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.

    SINAMICS Startdrive commissioning tool (V13 and higher)

    SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M 3), SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives.

    1) Available for firmware version V4.7 or higher

    2) SINAMICS G110M with AS-Interface is available from STARTER V4.4 SP1.

    3) SINAMICS G110M with AS-Interface is available from SINAMICS Startdrive V13 SP1.

    Дизайн

    The SINAMICS G110M distributed inverters are modular frequency inverters for standard drives. Each SINAMICS G110M comprises two operative units – a Power Module and a Control Unit.

    SINAMICS G110M CU240M PN Control Unit plug-in and PM240M Power Module FSA 1.5 kW (2 hp)

    Power Modules

    SINAMICS G110M PM240M Power Module FSA 1.5 kW (2 hp)

    The following PM240M Power Modules are available for the SINAMICS G110M distributed inverters:

    PM240M Power Modules
    Rated power

    Frame size

    0.37 kW (0.5 hp)

    FSA

    0.75 kW (1 hp)

    FSA

    1.1 kW (1.5 hp)

    FSA

    1.5 kW (2 hp)

    FSA

    2.2 kW (3 hp)

    FSB

    3 kW (4 hp)

    FSB

    4 kW (5 hp)

    FSB



    Control Units

    SINAMICS G110M CU240M PN Control Unit cable gland

    A Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization.

    The following Control Units are available for SINAMICS G110M distributed inverters:

    CU240M Control Units

    Several Control Units are available in different versions:

    Control Unit

    Fieldbus communication via

    Connection system

    For motor frame sizes

    CU240M

    USS/Modbus RTU

    Screw-type version

    71, 80/90, 100/112

    CU240M AS-i

    AS-Interface

    Screw-type version

    71, 80/90, 100/112

    CU240M AS-i

    AS-Interface

    Plug-in version

    71, 80/90, 100/112

    CU240M DP

    PROFIBUS

    Screw-type version

    71, 80/90, 100/112

    CU240M DP

    PROFIBUS

    Plug-in version

    71, 80/90, 100/112

    CU240M PN

    PROFINET, EtherNet/IP

    Screw-type version

    71, 80/90, 100/112

    CU240M PN

    PROFINET, EtherNet/IP

    Plug-in version

    71, 80/90, 100/112



    Supplementary system components

    Intelligent Operator Panel IOP Handheld

    The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, menu-based operation and the application wizards, it is easy to commission, diagnose and locally control standard drives.

    Memory card

    The parameter settings for the inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card, the system is immediately ready for use again.

    PC inverter connection kit (mini USB interface cable) for communication with a PC

    For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool V4.3 and higher or SINAMICS Startdrive V13 and higher) has been installed.

    Internal braking resistors

    Excess energy in the DC link is dissipated in the internal braking resistor.

    24 V DC power supply

    A 24 V DC power supply is also available for SINAMICS G110M. This is mounted directly on the inverter and supplies the device with 24 V DC, so there is no need to connect an external 24 V DC power supply.

    Wall mounting kit

    If a SINAMICS G110M distributed inverter should not or cannot be mounted on the motor, a wall mounting kit is available. With the wall mounting kit SINAMICS G110M can be mounted close to the motor – according to the conditions of the plant.

    Repair switch

    For SINAMICS G110M a repair switch is available. This is mounted directly on the inverter and separates SINAMICS G110M on the input side from the 400 V line supply.

    Connecting cable for the Control Units

    Flexible plug-in cables to transfer data between the Industrial Ethernet stations or PROFIBUS stations, as well as to supply power to the Control Unit.

    Connecting cable for the Power Modules

    Connector sets and pre-assembled cables for the line supply can be ordered as accessories.

    Installation kits

    Different installation kits can be ordered as accessories for the Control Units with plug-in connections and Control Units with cable gland connections.

    These kits include covers or cable glands for protecting or connecting the 400 V 3 AC supply, the 24 V DC supply and the mechanical motor brake.

    Spare Parts Kit

    A Spare Parts Kit is available which comprises small parts such as seals, caps and screws.

    Конфигурация

    The following electronic configuring aids and engineering tools are available for the SINAMICS G110M distributed inverters:

    Drive Technology Configurator (DT Configurator) within the CA 01

    The interactive catalog CA 01 – the offline Industry Mall of Siemens on DVD‑ROM – contains over 100 000 products with approximately 5 million possible drive system product variants. The Drive Technology Configurator (DT Configurator) has been developed to facilitate selection of the correct motor and/or inverter from the wide spectrum of drives. It is integrated in Catalog CA 01 as an add-on on DVD‑ROM.

    Online DT Configurator

    In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address:

    http://www.siemens.com/dt-configurator

    SIZER for Siemens Drives engineering tool

    The SIZER for Siemens Drives engineering tool makes it easy to engineer the SINAMICS drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER for Siemens Drives is designed to support configuring of the entire drive system.

    You can find further information on the SIZER for Siemens Drives engineering tool in the chapter Engineering tools.

    The SIZER for Siemens Drives engineering tool is available free on the Internet at
    http://www.siemens.com/sizer

    STARTER commissioning tool

    The STARTER commissioning tool allows menu-prompted commissioning, optimization and diagnostics. Apart from for SINAMICS drives, STARTER is also suitable for MICROMASTER 4 devices; for SINAMICS G110M from STARTER V4.3 SP3 and higher 1).

    You can find further information about the STARTER commissioning tool in the chapter Engineering tools.

    Additional information about the STARTER commissioning tool is available on the Internet at
    http://www.siemens.com/starter

    SINAMICS Startdrive commissioning tool (V13 and higher)

    SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M 2), SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives.

    You can find further information on the SINAMICS Startdrive commissioning tool in the chapter Engineering tools.

    The SINAMICS Startdrive commissioning tool is available free on the Internet at
    http://www.siemens.com/startdrive

    Drive ES engineering system

    Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Two software packages are available for SINAMICS – Drive ES Basic and Drive ES PCS.

    You can find further information about the Drive ES engineering system in the chapter Engineering tools.

    Additional information about the Drive ES engineering system is available on the Internet at 
    http://www.siemens.com/drive-es

    1) SINAMICS G110M with AS-Interface is available from STARTER V4.4 SP1.

    2) SINAMICS G110M with AS-Interface is available from SINAMICS Startdrive V13 SP1.

    Особенности

    Fast commissioning
    • Preconfigured with SIMOGEAR
    • Loop-through of 24 V DC and 400 V 3 AC and communication – no T-distributor necessary
    • Internal braking resistors - typical applications can be implemented without external braking resistors
    • Rugged, with IP65/66 degree of protection, up to 55 °C ambient temperature
    • Commissioning via fieldbus
    Fast commissioning on site
    • Local commissioning via DIP switch, standard USB interface and potentiometer or Intelligent Operator Panel (IOP)
    • Plug-in connections for 400 V 3 AC and 24 V DC, plug-in I/Os and communication
    • Local diagnostics with LEDs
    • Uploading, saving and cloning of parameters with SINAMICS SD card and IOP Intelligent Operator Panel
    Full functionality
    • Integrated safety functions (STO locally via F-DI or via PROFIsafe)
    • PROFINET communication to PROFIBUS at no extra cost
    • Integrated communication: USS, Modbus RTU, PROFIBUS, PROFINET / EtherNet/IP and AS-Interface
    • Basic PLC functions and additional conveyor technology functions
    • I/Os can be used as distributed I/Os of the PLC
    Efficient engineering
    • Fully integrated in Totally Integrated Automation, Totally Integrated Automation Portal and Integrated Drive System
    • Automatic diagnostics in combination with SIMATIC controller
    Flexible commissioning
    • Integrated, specific software functionality for conveyor systems:
      • Quick stop function for fast reaction times to sensors
      • Limit switch functionality, e.g. for rotary table, corner transfer unit
    • Use of the same software tools (STARTER and SINAMICS Startdrive) as for all SINAMICS drives

    Технические данные

    Unless explicitly specified otherwise, the following technical specifications are valid for all the following SINAMICS G110M distributed inverter components listed here.

    SINAMICS G110M

    Mechanical specifications

    Vibratory load

     

    • Transport acc. to EN 60721‑3‑2 1)

    Class 1M2

    • Operation acc. to EN 60721‑3‑3

    Class 3M3

    Shock load

     

    • Transport acc. to EN 60721‑3‑2 1)

    Class 1M2

    • Operation acc. to EN 60721‑3‑3

    Class 3M3

    Ambient conditions

     

    Protection class according to EN 61800‑5‑1

    Class III (PELV)

    Touch protection according to EN 61800‑5‑1

    Class I (with protective conductor system)

    Permissible ambient and coolant temperature (air)
    during operation for Power Modules

    -10 ... +40 ℃ (14 ... 104 °F) without derating

    >40 ... 55 ℃ (104 ... 131 °F) see derating characteristics

    Permissible ambient and coolant temperature (air)
    during operation for Control Units

    -10 ... +55 °C (14 ... 131 °F) without derating

    Humidity, max.

    95 % at 40 °C (104 °F)

    Ambient temperature

     

    • Storage 1) acc. to EN 60068‑2‑1

    -40 ... +70 °C (-40 ... +158 °F)

    • Transport 1) acc. to EN 60068‑2‑1

    -40 ... +70 °C (-40 ... +158 °F)

    • Operation acc. to EN 60068‑2‑2

    -10 ... +40 ℃ (14 ... 104 °F) without derating

    Environmental class/harmful chemical substances

     

    Operation acc. to EN 60721‑3‑3

    Class 3C2

    Degree of pollution acc. to EN 61800‑5‑1

    2

    Certification for fail-safe versions

    • According to IEC 61508

    SIL 2

    • According to EN ISO 13849‑1

    PL d and Category 3

    Standards

    Compliance with standards

    UL, cUL, CE, C-Tick (RCM)

    CE marking, according to

    Low-Voltage Directive 2006/95/EC

    EMC Directive 2)

     

    • Frame sizes FSA to FSC with integrated line filter class A

    Category C2  3) according to EN 61800‑3

     

    Note:

    The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive.



    1) In product packaging.

    2) For further general information, see also chapter SINAMICS G120, section Technical specifications, Compliance with standards.

    3) With shielded motor cable up to 5 m (16.41 ft).