Товаров
  
корзина пуста
  • Каталог оборудования Siemens

CP 441-1, CP 441-2

  • Заказные данные
    (2)
  • Аксессуары
    (16)
  • Информационные материалы

    Информационные материалы

    • For fast, high-performance serial data exchange via point-to-point connection
    • 2 versions:
      • CP 441-1 with 1 variable interface for easy point-to-point coupling.
      • CP 441-2 with 2 variable interfaces for high-performance point-to-point connection.
    • Plug-in interface modules for different physical transmission properties:
      RS 232C (V.24), 20 mA (TTY) or RS 422/RS 485 (X.27)
    • Implemented protocols: ASCII, 3964 (R), printer driver;
      for CP 441-2 additional RK 512 and Modbus RTU (reloadable)
    • Simple parameter assignment using tool integrated in STEP 7

    Область применения

    The CP 441 communications processor is used for fast, powerful serial data exchange over point-to-point connections, off-loading the CPU from communications tasks.

    Point-to-point connection is possible, for instance, for:

    • SIMATIC S7 and SIMATIC S5 programmable controllers, and systems from many other manufacturers
    • Programming devices and PCs
    • Printers
    • Robot controls
    • Scanners, bar code readers, etc.

    The communications processor come in two versions:

    • CP 441-1:
      With one variable interface, for simple and low-cost point-to-point connections.
    • CP 441-2:
      With two variable interfaces, for high-performance point-to-point connections.

    Дизайн

    The communication modules have the following mechanical features:

    • Rugged plastic enclosure
    • LEDs:
      for displaying "Send", "Receive" and "Error".
    • 1 (CP 441-1) or 2 (CP 441-2) slots for plug-in interface modules. Interface modules for the physical transmission media RS 232C (V.24), RS 422/485 or 20 mA (TTY) can be plugged into the slots

    The CP 441-2 and CP 441-2 can also be operated in expansion racks. However, transmission of the K bus signals must be guaranteed here.

    Drivers

    Different loadable drivers are available for the CP 441-2:

    • Modbus:
      For communication according to the Modbus protocol with RTU format:
      • Modbus master; master-slave interfacing with SIMATIC S7 as master.
      • Modbus slave; master-slave interfacing with SIMATIC S7 as slave, message frame traffic from slave to slave not possible.

    The two serial interfaces of the CP 441-2 can be operated independently of each other with different standard protocols or loadable drivers together with the V.24/TTY/X.27 interface modules.

    Функции

    User-friendly functions make the communication modules flexible and cost-effective:

    • Different transmission protocols:
      • 3964 (R), for connecting Siemens devices;
      • RK 512, for connecting computers (only for CP 441-2);
      • Printer drivers, for controlling printers;
      • ASCII, for the easy and variable connection of third-party devices;
      • For CP 441-2 additional use of Modbus RTU possible (reloadable drivers)
    Parameter assignment

    Parameterization of the CP 441-1 and CP 441-2 communication modules is especially user-friendly and simple:

    • STEP 7 tool for communications configuration:
      The user uses the communications configuration to define which protocol driver is to be used or which driver-specific properties are to be used.
    • Parameter assignment via the CPU:
      The PG is simply connected to the CPU. Communication with the CP takes place via the C bus.

    The configuration data is saved in a data block, which is saved in the memory card of the CPU. When modules are replaced, the new module is therefore immediately ready for use.

    • Configuration package (on CD):
      With electronic manual and parameterization input screens. As of STEP 7 V11 (TIA Portal), the necessary parameterization input screens are already integrated.
    Configuring the drivers

    The SIMATIC PtP CP Loadable Drivers Configuration Package and STEP 7 (V5.3 or higher) are required to load and configure the drivers. The drivers are copy-protected by a dongle.

    Технические данные

    Order number

    6ES7441-1AA05-0AE0

    6ES7441-2AA05-0AE0

    SIMATIC S7-400, CP 441-1

    CP 441-2, PTP-CONN.., 2 CHANNELS

    General information

     

     

    Product type designation

    CP 441-1

    CP 441-2

    Supply voltage

     

     

    Rated value (DC)

    • 5 V DC

    Yes

    Yes

    • 24 V DC

    Yes

    Yes

    Input current

     

     

    from backplane bus 5 V DC, max.

    300 mA

    300 mA

    Power loss

     

     

    Power loss, typ.

    2.1 W; incl. 1x20 mA TTY module

    2.7 W; incl. 2x20mA TTY module

    Memory

     

     

    Memory requirements per interface in memory card of S7-CPU

    1 to 5 KB for parameters; 0 to 55 KB for message texts

    1 to 5 KB for parameters; 0 to 55 KB for message texts; 0 to 64 KB for loadable drivers

    Interfaces

     

     

    Number of interfaces

    1; variable

    2; variable

    Interface physics, 20 mA (TTY)

    Yes

    Yes

    Interface physics, RS 232C (V.24)

    Yes

    Yes

    Interface (physical) RS 422/485 (X.27)

    Yes

    Yes

    20 mA (TTY), cable length shielded, max.

    1 000 m; At 9600 bps

    1 000 m; At 9600 bps

    RS 232, cable length shielded, max.

    15 m; At 115200 bps

    15 m; At 115200 bps

    RS 422/RS 485, cable length shielded, max.

    1 200 m; At 19200 bps

    1 200 m; At 19200 bps

    Point-to-point

     

     

    • Transmission rate, max.

    115.2 kbit/s; Min. 300 bps

    115.2 kbit/s; Min. 300 bps

    • supported printers

    HP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined

    HP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined

    Integrated protocol driver

     

     

    • 3964 (R)

    Yes

    Yes

    • ASCII

    Yes

    Yes

    • RK512

    No

    Yes

    • Printer

    Yes

    Yes

    • customer-specific drivers reloadable

    No

    No

    Transmission rate, 20 mA (TTY)

     

     

    • with 3964 (R) protocol, max.

    19.2 kbit/s

    19.2 kbit/s

    • with ASCII protocol, max.

    19.2 kbit/s

    19.2 kbit/s

    • with printer driver, max.

    19.2 kbit/s

    19.2 kbit/s

    • with RK 512 protocol, max.

    19.2 kbit/s

    Transmission rate, RS 422/485

     

     

    • with 3964 (R) protocol, max.

    115.2 kbit/s

    115.2 kbit/s

    • with ASCII protocol, max.

    115.2 kbit/s

    115.2 kbit/s

    • with printer driver, max.

    115.2 kbit/s

    115.2 kbit/s

    • with RK 512 protocol, max.

    115.2 kbit/s

    Transmission speed, RS 232

     

     

    • with 3964 (R) protocol, max.

    115.2 kbit/s

    115.2 kbit/s

    • with ASCII protocol, max.

    115.2 kbit/s

    115.2 kbit/s

    • with printer driver, max.

    115.2 kbit/s

    115.2 kbit/s

    • with RK 512 protocol, max.

    115.2 kbit/s

    Ambient conditions

     

     

    Ambient temperature during operation

     

     

    • min.

    0 °C

    0 °C

    • max.

    60 °C

    60 °C

    Relative humidity

     

     

    • Operation, max.

    95 %

    95 %

    Dimensions

     

     

    Width

    25 mm

    25 mm

    Height

    290 mm

    290 mm

    Depth

    210 mm

    210 mm

    Weights

     

     

    Weight, approx.

    580 g; Interface modules: 80 g

    580 g; Interface modules: 80 g


    Дальнейшая информация

    Brochures

    Information material for downloading can be found in the Internet:

    http://www.automation.siemens.com/infocenter