- Каталог оборудования Siemens
- Каталог продуктов Siemens Industry
- Приводная техника
- Техника автоматизации
- Системы автоматизации
- Промышленные системы автоматизации SIMATIC
- Программируемые контроллеры
- Логические модули LOGO!
- Базовый контроллер
- SIMATIC S7
- S7-1500
- S7-300/ S7-300F/ SIPLUS S7-300
- S7-400/S7-400H/S7-400F/FH
- Demonstration models
- Central processing units
- Signal modules
- Function modules
- Communication
- CP 440
- CP 441-1, CP 441-2
- Loadable drivers for CP 441-2 and CP 341
- CP 443-5 Basic
- CP 443-5 Extended
- CP 443-1
- CP 443-1 Advanced
- CP 443-1 Advanced
- TIM 4R-IE (for S7-300/-400/PC)
- TIM 4R-IE DNP3 (for S7-300/-400)
- SCALANCE M875 UMTS mobile wireless router
- Network Components for PROFIBUS
- Cabling Technology
- SIPLUS S7-400 communication
- Connection method
- Racks
- SIPLUS S7-400 racks
- Interface modules
- PS 405/407 power supply
- SIPLUS S7-400 power supplies
- Accessories
- S7-400H
- S7-400F/FH
- Контроллеры для распределенных систем
- Программный контроллер
- Дополнительные компоненты
- Распределенный ввод/вывод
- Система автоматизации SIMATIC TDC
- Программное обеспечение для SIMATIC S7/WinAC
- Программаторы
- SIEMENS Solution Partner
- Test
- Программируемые контроллеры
- Motion Control - система SIMOTION
- Системы автоматизации на базе СЧПУ SINUMERIK
- Система соединителей/ шкафы управления
- Программное обеспечение для систем автоматизации
- Промышленные системы автоматизации SIMATIC
- Системы визуализации SIMATIC HMI
- Системы идентификации
- Промышленные коммуникации SIMATIC NET
- Промышленные аппараты управления SIRIUS
- Промышленные информационные технологии
- Управление на базе РС
- Системы управления процессом
- Контрольно-измерительные приборы
- Анализаторы процесса
- Блоки питания SITOP
- Продукты для специальных требований
- Системы автоматизации
- Energy
- Автоматизация и безопасность зданий
- Низковольтная коммутационная техника
- Технология безопасности
- Системные решения и продукты для отраслей
- Сервис
- Заказные данные (1)
- Аксессуары (26)
- Информационные материалы
Информационные материалы
Communications processor for connecting a SIMATIC S7-400 to Industrial Ethernet networks, also as PROFINET IO controller or in SIMATIC H systems.
The CP supports:
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
- PROFINET communication
- IT communication
- Security functionality, firewall and VPN
The communications processor can also be used for redundant S7 communication in SIMATIC H systems and for fail-safe applications (PROFIsafe) in connection with an S7-400 F-CPU. In addition, the CP 443-1 Advanced provides e-mail functions and user-created Web pages, offering ideal support for maintenance and quality assurance. The Internet functions such as FTP even allow connection to the most diverse PC-based systems. This CP is therefore the bridge between the field level and the management level for the S7-400. The CP 443-1 Advanced connects seamlessly to the security structures of the office and IT worlds.
Область применения
The CP 443-1 Advanced is used to connect the SIMATIC S7-400 to Industrial Ethernet networks. With its own processor, it relieves the CPU of communication tasks and facilitates additional connections.
The CP 443-1 Advanced provides the following communication options:
- PGs/PCs
- Master computers
- HMI systems
- SIMATIC S5/S7/C7 systems
- PROFINET I/O devices
- PROFINET CBA components
All the devices of an Ethernet network can be protected from unauthorized access. The CP 443-1 Advanced allows safe remote access over the Internet and allows data transfer between devices or network segments to be protected from data manipulation/espionage.
PROFINET CBA components and security functionalities can be used as an alternative.
Secure VPN communication between SCALANCE S, SOFTNET Security Client and components with Security Integrated
Дизайн
The CP 443-1 Advanced offers all the advantages of SIMATIC S7-400 system design:
- Compact design:
- Five RJ45 jacks for connecting to Industrial Ethernet via two independent interfaces; one of which is a security socket for externally safeguarding the network cell; automatic data rate detection by means of the autosensing and autocross function; the connection is made via the IE FC RJ45 Plug 180 with 180° cable outlet or via a standard patch cable
- Diagnostics LEDs for indicating the operational and communication status
- Simple installation;
the CP 443-1 Advanced is mounted on the S7-400 rack and connected to other modules by means of the backplane bus. There are no slot rules. - The CP 443-1 Advanced can be operated without a fan.
- In combination with IM 460/461, the CP 443-1 Advanced can also be used in an expansion rack (ER).
- The module can be replaced without the need for a programming device
- C-PLUG (configuration plug) is included in scope of delivery as a swap medium (cannot be operated without C-PLUG).
Функции
- Two separate interfaces (integrated network separation):
- Gigabit interface with one RJ45 port with 10/100/1 000 Mbps, full/half-duplex with auto-sensing capability
- PROFINET interface with four RJ45 ports with 10/100 Mbps full/half duplex with autosensing and autocrossover functionality via integrated 4-port switch
- Communication services via both interfaces:
- Open communication (TCP/IP and UDP):
Multicast with UDP, including routing between both interfaces - PG/OP communication: Inter-network with S7 routing
- S7 communication (client, server, multiplexing) including routing between both interfaces
- S7 H communication for S7-400 H systems, now also across network boundaries (ISO-on-TCP)
- IT communication:
HTTP communication permits access to process data via user's own Web pages. HTTPS communication is also possible with the CP 443-1 Advanced1).
The e-mail client function allows e-mails to be sent directly from the user program.
FTP communication allows program-controlled FTP client communication.
Access to data blocks via FTP server.
- Open communication (TCP/IP and UDP):
- Communication services via PROFINET interfaces:
- Certified PROFINET IO controller with real-time properties (RT and IRT)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or via user program (e.g. for HMI)
- Media redundancy (MRP):
- Within an Ethernet network with a ring topology, the CP supports the MRP media redundancy protocol as an MRP manager and as an MRP client
- Diagnostics and network management:
- Comprehensive diagnostics functions for all modules in the rack (including graphical diagnostics, e.g. topology)
- Integration in network management systems due to support of SNMP V1/V3
- Security mechanisms:
- Access protection by means of configurable IP access list
- Firewall for filtering connections on the basis of their IP/port addresses
- Bandwidth limitation to avoid communication overload
- VPN server and VPN client for tap-proof access to controllers
- Encrypted HTML pages using SSL (HTTPs)
- Secure file transfer (FTPs)
- Tap-proof transfer of network analysis information to the network management system (SNMP)
- Translation of private and public IP addresses (NAT/NAPT)
- Secure transfer of the time of day (NTP V3)
- Secure firmware update
- Plagiarism detection
- Certification as per the Achilles Level II Standard
http://www.wurldtech.com/product_services/certifications/certified_products/
- Configuration of all functions with STEP 7;
The security functions are configured using the Security Configuration Tool (SCT) included in the scope of delivery for STEP 7 V5.5 SP2 HF1. - Configuration with STEP 7 Professional V11;
only possible with a limited range of functions of the predecessor CP 443-1 (6GK7 443-1GX20-0XE0), without security functions and CBA.
Version with security functions for TIA Portal in the planning stages. - When using the blocks AG_SSEND (FC53), AG_SRECV (FC63), TSEND (FB63), TRCV (FB64), TCON (FB65) and TDISCON (FB66), please note the following information: http://support.automation.siemens.com/WW/view/en/60037071
- Module replacement without programming device:
All information is stored on the C-PLUG (as well as file system for IT functions)
Интеграция
Connection to higher-level network
Small independent local networks (e.g. within a machine or cell)
Особенности
- Cost advantage due to connection to two separate Ethernet segments with integrated network separation
- High plant availability through the support of media redundancy (MRP) and use in the SIMATIC S7-400 H system
- Optimum support of maintenance through
- Web-based diagnostics
- Remote programming via WAN or telephone network (ISDN)
- Monitoring with IT network management tools (SNMP)
- Module replacement without programming device using the C-PLUG swap medium
- Securing the system against unauthorized access by means of
- Central access protection for any devices within an automation cell, e.g. by means of authentication of the network stations
- Secure remote access via the Internet by means of data encryption (VPN) and data integrity checking
- Traceability by means of data logging on the basis of standard IT mechanisms (Syslog)
- Later connection of existing SIMATIC S7 systems to Industrial Ethernet using the CP 443-1 Advanced ensures investment protection
Технические данные
Order number
6GK7443-1GX30-0XE0
Product type designation
CP 443-1 Advanced
Transmission rate
Transfer rate
● at the 1st interface
10 ... 1 000 Mbit/s
● at the 2nd interface
10 ... 100 Mbit/s
Interfaces
Number of interfaces acc. to Industrial Ethernet
5
Number of electrical connections
● at the 1st interface acc. to Industrial Ethernet
1
● at the 2nd interface acc. to Industrial Ethernet
4
Type of electrical connection
● at the 1st interface acc. to Industrial Ethernet
RJ45 port
● at the 2nd interface acc. to Industrial Ethernet
RJ45 port
design of the removable storage C-PLUG
Yes
Supply voltage, current consumption, power loss
Type of voltage of the supply voltage
DC
Supply voltage 1 from backplane bus
5 V
Relative symmetrical tolerance at DC
● at 5 V
5 %
Consumed current
● from backplane bus at DC at 5 V typical
1.8 A
Power loss [W]
9 W
Permitted ambient conditions
Ambient temperature
● during operation
0 ... 60 °C
● during storage
-40 ... +70 °C
● during transport
-40 ... +70 °C
Relative humidity at 25 °C without condensation during operation maximum
95 %
Protection class IP
IP20
Design, dimensions and weight
Module format
Compact module S7-400 single width
Width
25 mm
Height
290 mm
Depth
210 mm
Net weight
0.7 kg
Product properties, functions, components general
Number of units
● per CPU maximum
14
● Note
max. 4 as PN IO ctrl.
Performance data open communication
Number of possible connections for open communication by means of SEND/RECEIVE blocks maximum
64
Amount of data
● as user data per ISO connection for open communication by means of SEND/RECEIVE blocks maximum
8 Kibyte
● as user data per ISO on TCP connection for open communication by means of SEND/RECEIVE blocks maximum
8 Kibyte
● as user data per TCP connection for open communication by means of SEND/RECEIVE blocks maximum
8 Kibyte
● as user data per UDP connection for open IE communication by means of SEND/RECEIVE blocks maximum
2 Kibyte
Number of possible connections for open communication
● by means of T blocks maximum
64
Amount of data
● as user data per ISO on TCP connection for open communication by means of T blocks maximum
1 452 byte
Performance data S7 communication
Number of possible connections for S7 communication
● maximum
128
● with PG connections maximum
2
● Note
when using several CPUs
Performance data multi-protocol mode
Number of active connections with multi-protocol mode
128
Performance data IT functions
Number of possible connections
● as client by means of FTP maximum
20
● as server by means of FTP maximum
10
● as server by means of HTTP maximum
4
● as e-mail client maximum
1
Amount of data as user data for email maximum
8 Kibyte
Storage capacity of the user memory
● as flash memory file system
30 Mibyte
● as RAM
16 Mibyte
● additionally buffered as RAM via central backup battery
512 Kibyte
Number of possible write cycles of the flash memory cells
100 000
Performance data PROFINET communication as PN IO-Controller
Product function PROFINET IO controller
Yes
Number of PN IO devices on PROFINET IO controller usable total
128
Number of PN IO IRT devices on PROFINET IO controller usable
64
Number of external PN IO lines with PROFINET per rack
4
Amount of data
● as user data for input variables as PROFINET IO controller maximum
4 Kibyte
● as user data for input variables as PROFINET IO controller maximum
4 Kibyte
● as user data for input variables per PN IO device as PROFINET IO controller maximum
1 433 byte
● as user data for output variables per PN IO device as PROFINET IO controller maximum
1 433 byte
● as user data for input variables per PN IO device for each sub-module as PROFINET IO controller maximum
240 byte
● as user data for output variables per PN IO device for each sub-module as PROFINET IO controller maximum
240 byte
Performance data PROFINET CBA
Number of remote connection partners with PROFINET CBA
64
Number of connections with PROFINET CBA total
600
Amount of data
● as user data for digital inputs with PROFINET CBA maximum
8 Kibyte
● as user data for digital outputs with PROFINET CBA maximum
8 Kibyte
● as user data for arrays and data types in the case of acyclic transmission with PROFINET CBA maximum
8 Kibyte
● as user data for arrays and data types with PROFINET CBA with cyclical transfer maximum
250 byte
● as user data for arrays and data types with PROFINET CBA in the case of local interconnection maximum
2 400 byte
Performance data PROFINET CBA remote connection with acyclic transmission
Refresh time of the remote interconnections in the case of acyclic transmission with PROFINET CBA
100 ms
Number of remote connections to input variables in the case of acyclic transmission with PROFINET CBA maximum
150
Number of remote connections to output variables in the case of acyclic transmission with PROFINET CBA maximum
150
Amount of data
● as user data for remote interconnections with input variables in the case of acyclic transmission with PROFINET CBA
8 Kibyte
● as user data for remote interconnections with output variables in the case of acyclic transmission with PROFINET CBA
8 Kibyte
Performance data PROFINET CBA remote connection with cyclic transmission
Refresh time of the remote interconnections with PROFINET CBA with cyclical transfer
10 ms
Number of remote connections to input variables with PROFINET CBA with cyclical transfer maximum
250
Number of remote connections to output variables with PROFINET CBA with cyclical transfer maximum
250
Amount of data
● as user data for remote interconnections with input variables with PROFINET CBA with cyclical transfer maximum
2 000 byte
● as user data for remote interconnections with output variables with PROFINET CBA with cyclical transfer maximum
2 000 byte
Performance data PROFINET CBA HMI variables via PROFINET acyclic
Number of connectable HMI stations for HMI variables in the case of acyclic transmission with PROFINET CBA
3
Refresh time of the HMI variables in the case of acyclic transmission with PROFINET CBA
500 ms
Number of HMI variables in the case of acyclic transmission with PROFINET CBA maximum
200
Amount of data as user data for HMI variables in the case of acyclic transmission with PROFINET CBA maximum
8 Kibyte
Performance data PROFINET CBA device-internal connections
Number of internal connections with PROFINET CBA maximum
300
Amount of data of the internal connections with PROFINET CBA maximum
2 400 byte
Performance data PROFINET CBA connections to constants
Number of connections with constants with PROFINET CBA maximum
500
Amount of data as user data for interconnections with constants with PROFINET CBA maximum
4 000 byte
Performance data PROFINET CBA PROFIBUS proxy functionality
Product function with PROFINET CBA PROFIBUS proxy functionality
No
Product function MIB support
Yes
Protocol is supported
● SNMP v1
Yes
● SNMP v3
Yes
● DCP
Yes
● LLDP
Yes
Configuration software
● required
STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher
● for PROFINET CBA required
SIMATIC iMap V3.0 SP1 and higher
Product functions Diagnosis
Product function Web-based diagnostics
Yes
Product functions switch
Product feature Switch
Yes
Product function
● switch-managed
No
● with IRT PROFINET IO switch
Yes
● Configuration with STEP 7
Yes
Product functions Redundancy
Product function
● Ring redundancy
Yes
● Redundancy manager
Yes
● Parallel Redundancy Protocol (PRP)/operation in the PRP-network
Yes
Protocol is supported Media Redundancy Protocol (MRP)
Yes
Product functions Security
Firewall version
stateful inspection
Product function with VPN connection
IPSec
Type of encryption algorithms with VPN connection
AES-256, AES-192, AES-128, 3DES-168, DES-56
Type of authentication procedure with VPN connection
Preshared key (PSK), X.509v3 certificates
Type of hashing algorithms with VPN connection
MD5, SHA-1
Number of possible connections with VPN connection
32
Product function
● password protection for Web applications
Yes
● ACL - IP-based
Yes
● ACL - IP-based for PLC/routing
Yes
● switch-off of non-required services
Yes
● Blocking of communication via physical ports
Yes
● log file for unauthorized access
No
Product functions Time
Product function SICLOCK support
Yes
Product function pass on time synchronization
Yes
Protocol is supported
● NTP
Yes
Дальнейшая информация
You will find more information on the topic of Industrial Security on the Internet at:
http://www.siemens.com/industrialsecurity