- Каталог оборудования Siemens
- Каталог продуктов Siemens Industry
- Приводная техника
- Преобразователи
- Стандартные преобразователи
- Общая информация о базовых преобразователях SINAMICS V
- Преобразователи частоты общего назначения SINAMICS G
- Высокопроизводительные преобразователи SINAMICS S
- Сервопреобразователь SINAMICS S110
- SINAMICS S120
- SINAMICS S120M distributed servo drive
- SINAMICS S120 Combi
- SINAMICS S120 Chassis Format Units
- Air-cooled units
- Liquid-cooled units
- System components
- Line-side power components
- DC link components
- Motor-side power components
- Control Units
- Supplementary system components
- BOP20 Basic Operator Panel
- AOP30 Advanced Operator Panel
- CBC10 Communication Board
- CBE20 Communication Board
- DMC20 DRIVE-CLiQ Hub Module
- DME20 DRIVE-CLiQ Hub Module
- TB30 Terminal Board
- TM15 Terminal Module
- TM31 Terminal Module
- TM41 Terminal Module
- TM41 Terminal Module
- TM54F Terminal Module
- TM120 Terminal Module
- TM150 Terminal Module
- VSM10 Voltage Sensing Module
- Safe Brake Adapter SBA
- Encoder system connection
- Connection system
- SINAMICS S120 Cabinet Modules
- SINAMICS S150 converter cabinet units
- MICROMASTER
- SIPLUS POSMO A
- SIMODRIVE POSMO
- LOHER DYNAVERT Drive System
- Преобразователи на среднее напряжение
- Преобразователи постоянного тока
- Стандартные преобразователи
- Двигатели переменного тока
- Generators
- Мотор-редукторы
- Flender Gear Units
- Couplings
- Инструментальное программное обеспечение
- Дополнительные компоненты
- Преобразователи
- Техника автоматизации
- Energy
- Автоматизация и безопасность зданий
- Низковольтная коммутационная техника
- Технология безопасности
- Системные решения и продукты для отраслей
- Сервис
- Приводная техника
- Заказные данные (1)
- Аксессуары (1)
- Информационные материалы
Информационные материалы
TM41 Terminal Module
The TM41 Terminal Module supplies TTL signals which emulate an incremental encoder, e.g. to a higher-level control. The encoder interface (incremental encoder emulation) can be linked to an encoder signal from the Control Unit, e.g. incremental encoder sin/cos, by parameter assignment.
The TM41 Terminal Module increases the number of digital inputs/outputs and analog inputs that are available in the drive system.
Дизайн
The following are located on the TM41 Terminal Module:
- 4 bidirectional digital inputs/outputs
- 4 digital inputs (with electrical isolation)
- 1 analog input
- 1 interface for emulation of TTL incremental encoder (RS422)
- 1 LED for signaling zero mark detection for encoder interface
- 2 DRIVE‑CLiQ sockets
- 1 connection for the electronics power supply and to supply the digital outputs via the 24 V DC power supply connector
- 1 PE (protective earth) connection
The status of the TM41 Terminal Module is indicated via a multi-color LED.
An LED next to the interface for TTL pulse encoder emulation is illuminated as soon as a zero mark is detected.The TM41 Terminal Module can be snapped onto a TH 35 standard mounting rail in accordance with EN 60715 (IEC 60715).
The signal cable shield can be attached to the TM41 Terminal Module via a shield connection terminal, e.g. type SK8 supplied by Phoenix Contact or type KLBÜ CO 1 supplied by Weidmüller. The shield connection terminal must not be used as a strain relief mechanism.
Интеграция
The TM41 Terminal Module can communicate via DRIVE‑CLiQ with the following Control Units.
- CU310‑2 Control Unit
- CU320‑2 Control Unit
- SINUMERIK Control Unit
- SIMOTION D Control Unit
Connection example of TM41 Terminal Module
Технические данные
TM41 Terminal Module
6SL3055-0AA00-3PA1
Current requirement
(X524 at 24 V DC) without DRIVE-CLiQ supply or digital outputs (X514)
0.5 A
- Conductor cross-section, max.
2.5 mm2
- Fuse protection, max.
20 A
I/O
- Digital inputs/outputs
Individually parameterizable as DI or DO
- Number of digital inputs/outputs
4
- Number of digital input/outputs
(with isolation)
4
- Cables and connections
Plug-in screw-type terminals
- Conductor cross-section, max.
1.5 mm2
Digital inputs
- Voltage
- Without electrical isolation
-3 ... +30 V
- With electrical isolation
-30 ... +30 V
- Low level
(an open digital input is interpreted as "low")
- Without electrical isolation
-3 ... +5 V
- With electrical isolation
-30 ... +5 V
- High level
15 ... 30 V
- Current consumption at 24 V DC, typ.
<9 mA
- Delay times of digital inputs, max. 1)
- L → H
3 ms
- H → L
3 ms
Digital outputs
(continuously short-circuit proof)
- Voltage
24 V DC
- Load current per digital output, max.
0.5 A
- Delay times (resistive load) 1)
- L → H, typ.
50 μs
- L → H, max.
100 μs
- H → L, typ.
75 μs
- H → L, max.
150 μs
Analog input
difference
- Voltage range
-10 ... +10 V
- Internal resistance
≥100 kΩ
- Resolution 2)
12 bits + sign
Pulse encoder emulation
- Level
TTL (RS422), A+, A-, B+, B-, zero track N+, N-
- Limit frequency fmax.
512 kHz
- Ratio
Encoder pulses : Encoder emulation
Any number of ratio/reduction ratio of pulses
Power loss, max.
12 W
PE connection
M4 screw
Dimensions
- Width
30 mm (1.18 in)
- Height
151 mm (5.94 in)
- Depth
110 mm (4.33 in)
Weight, approx.
0.32 kg (0.71 lb)
Certificate of suitability
cULus
1) The specified delay times refer to the hardware. The actual reaction time depends on the time slot in which the digital input/output is processed.
2) If the analog input is to be operated in the signal processing sense with continuously variable input voltage, the sampling frequency fa = 1/ttime slice must be at least twice the value of the highest signal frequency fmax.