Товаров
  
корзина пуста
  • Каталог оборудования Siemens

AOP30 Advanced Operator Panel

  • Заказные данные
    (1)
  • Аксессуары
    (1)
  • Информационные материалы

    Информационные материалы

    The AOP30 Advanced Operator Panel is an input/output device for converters of the SINAMICS series, preferably for cabinet installation.

    It has the following characteristics:

    • Graphical backlit LCD display for plain text display and a bar display of process variables
    • LEDs for display of the operating states
    • Help function describing causes of and remedies for faults and alarms
    • Keypad for operational control of a drive
    • Local/remote switchover for selecting the operating location (control priority assigned to operator panel or customer terminal block / communication channel)
    • Numeric keypad for input of setpoint or parameter values
    • Function keys for guided navigation in the menu
    • Two-stage safety concept to protect against accidental or unauthorized changes to settings.
      • Operation of the drive from the operator panel can be disabled by the keyboard lock so that only parameter values and process variables can be displayed on the operator panel.
      • A password can be used to prevent the unauthorized modification of converter parameters.
    • Front panel with degree of protection IP55

    The AOP30 and SINAMICS drive communicate via the RS232 serial interface with PPI protocol.

    The AOP30 may be omitted if the drive is only operated via PROFIBUS, for example, and no local display is required on the cabinet. The AOP30 can then be used simply for commissioning purposes and to obtain diagnostic information, in which case, it is plugged into the RS232 interface on the CU320‑2 Control Unit. In this case, an external 24 V power supply (max. current requirement 200 mA) is required.

    Assignment of the serial plug-in cable

    Дизайн

    The AOP30 is an operator panel with graphical display and membrane keyboard. The device can be installed in a cabinet door which is between 2 mm and 4 mm thick.

    Features:

    • Display with green backlighting, resolution 240 × 64 pixels
    • Membrane keyboard with 26 keys
    • Connection for a 24 V power supply
    • RS232 interface
    • Time and date memory with internal battery backup
    • 4 LEDs to indicate the operating state of the drive:
      • RUN green
      • ALARM yellow
      • FAULT red
      • Local/Remote green

    Функции

    The current operating states, setpoints and actual values, parameters, indices, faults and alarms are displayed on the display panel.

    German, English, French, Italian, Spanish and Chinese are stored on the CU320‑2 Control Unit CompactFlash card as operator panel languages. The desired language must be downloaded to the AOP30 prior to commissioning. In addition to these preinstalled languages, Russian and Portuguese (Brazil) are also available for subsequent installation. Further languages are available on request.

    Интеграция

    If just one CU320‑2 Control Unit controls several power units (multi-motor drives) in the SINAMICS S120 drive system, the parameters, alarms and faults of all the connected devices can be simultaneously displayed and processed on the AOP30 Advanced Operator Panel.

    Технические данные

     

    AOP30 Advanced Operator Panel

    6SL3055-0AA00-4CA5

    Power supply

    24 V DC (20.4 ... 28.8 V DC)

    Current requirement

     

    • Without backlighting

    <100 mA

    • For max. backlighting

    < 200 mA

    Data interface

    RS232 interface,
    PPI protocol

    Backup battery

    3 V lithium CR2032

    Operating temperature

    0 ... 55 °C

    Storage and transport temperature

    -25 ... +70 °C

    Degree of protection

    IP20 for the inside of the cabinet
    IP55 for the outside of the cabinet

    Dimensions

     

    • Width

    212 mm

    • Height

    156 mm

    • Depth

    31 mm

    Weight, approx.

    0.55 kg