Товаров
  
корзина пуста
  • Каталог оборудования Siemens

Motor Modules

  • Заказные данные
    (14)
  • Информационные материалы

    Информационные материалы

    Motor Modules are available in the power range from 90 kW to 1500 kW.

    Line voltage

    DC link voltage

    Type rating

    380 ... 480 V 3 AC

    510 ... 720 V DC

    315 ... 800 kW

    500 ... 690 V 3 AC

    675 ... 1035 V DC

    450 ... 1500 kW



    By connecting in parallel up to four Motor Modules, which are operated on one Control Unit and supply one motor, it is possible to increase the available shaft power to max. approx. 5700 kW (taking into account the derating factors according to the SINAMICS Low Voltage Engineering Manual).

    The Motor Modules can also be used as Braking Modules (braking chopper) if a 3‑phase braking resistor is connected instead of a motor.
    For more detailed information on this topic, please refer to the SINAMICS Low Voltage Engineering Manual.

    Дизайн

    Motor Modules contain the following components as standard:

    • Retaining device for the DC busbar, including the connection to the DC connections of the Motor Module
    • Connection busbars, nickel-plated
      • on Motor Modules, frame size JXL, the connection for the motor cables is routed to the right of the device
      • on Motor Modules, frame size HXL, the connection is underneath the device
    • Cable retaining bar for the power cables
    • DRIVE‑CLiQ interface (three DRIVE‑CLiQ sockets), without Control Unit
    • Auxiliary power supply system (4-pole) for the auxiliary power supply, including cable connections for looping through to the next Cabinet Module
    • Nickel-plated PE busbar (60 x 10 mm), including jumper for looping through to the next Cabinet Module
    • EMC-compliant design thanks to additional shielding measures and appropriately routed cables

    Интеграция

    Motor Modules are controlled by the CU320‑2 DP or CU320‑2 PN Control Unit. Communication between the Control Unit and Modules is established via a DRIVE‑CLiQ connection.

    If the Control Unit is integrated in the same cabinet as an option with order code K90 or K95, these communication cables will already be installed. If the Control Unit is to be mounted externally, the DRIVE‑CLiQ cable will not be included in the scope of delivery and must be configured on site.

    For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

    Connection example of a Motor Module, liquid-cooled

    Технические данные

    Line voltage 380 ... 480 V 3 AC

    DC link voltage 510 ... 720 V DC

    Motor Modules

    6SL3725-1TE36-1AA3

    6SL3725-1TE37-5AA3

    6SL3725-1TE38-4AA3

    Type rating

     

     

     

     

    • At IL (50 Hz 400 V) 1)

    kW

    315

    400

    450

    • At IH (50 Hz 400 V) 1)

    kW

    250

    315

    400

    • At IL (60 Hz 460 V) 2)

    hp

    500

    600

    700

    • At IH (60 Hz 460 V) 2)

    hp

    350

    450

    600

    Output current

     

     

     

     

    • Rated current Irated O

    A

    605

    745

    840

    • Base-load current IL3)

    A

    590

    725

    820

    • Base-load current IH4)

    A

    460

    570

    700

    • Maximum current Imax O

    A

    885

    1087

    1230

    DC link current

     

     

     

     

    • Rated current Irated DC
      when supplied via

     

     

     

     

    • Basic Line Module

    A

    738

    894

    1025

    • Active Line Module

    A

    664

    805

    922

    • Base-load current IL DC 3)
      when supplied via

     

     

     

     

    • Basic Line Module

    A

    719

    871

    1000

    • Active Line Module

    A

    646

    784

    898

    • Base-load current IH DC 4)
      when supplied via

     

     

     

     

    • Basic Line Module

    A

    561

    795

    853

    • Active Line Module

    A

    504

    716

    767

    Current demand

     

     

     

     

    • 24 V DC auxiliary power supply

    A

    1.6

    1.6

    1.6

    • 230 V 1 AC

    A

    0.6

    0.6

    0.6

    DC link capacitance

    μF

    12600

    17400

    17400

    Pulse frequency 5)

     

     

     

     

    • Rated frequency

    kHz

    1.25

    1.25

    1.25

    • Pulse frequency, max.

     

     

     

     

    • Without current derating

    kHz

    1.25

    1.25

    1.25

    • With current derating

    kHz

    7.5

    7.5

    7.5

    Power loss, max. 6)

    at 50 Hz 400 V

     

     

     

     

    • Degree of protection <IP55

     

     

     

     

    • Dissipated to coolant

    kW

    4.6

    5.2

    5.5

    • Dissipated to ambient air

    kW

    0.6

    0.7

    0.8

    • Degree of protection IP55

     

     

     

     

    • Dissipated to coolant

    kW

    5.0

    5.7

    6.2

    • Dissipated to ambient air

    kW

    0.2

    0.2

    0.2

    Coolant volume flow 7)

    all degrees of protection

    l/min

    16

    16

    16

    Liquid volume

    Degree of protection <IP55/IP55

    dm3

    3.3/5.1

    3.3/5.1

    3.3/5.1

    Pressure drop, max. 8)

    for volume flow

    Pa

    150000

    150000

    150000

    Heat exchanger material

     

    Aluminum

    Aluminum

    Aluminum

    Sound pressure level LpA

    (1 m) at 50/60 Hz

    dB

    54

    54

    54

    Motor connection

    U2, V2, W2

     

    2/M12

    2/M12

    2/M12

    • Conductor cross section, max. (IEC)

    mm2

    4 × 185

    4 × 185

    4 × 185

    PE/GND connection

     

    PE bar

    PE bar

    PE bar

    • Busbar cross-section

    mm2

    600

    600

    600

    • Conductor cross section, max. (IEC)

    mm2

    240

    240

    240

    Cable length, max. 9)

    Shielded/unshielded

     

    300/450

    300/450

    300/450

    Degree of protection (standard version)

     

    IP21

    IP21

    IP21

    Dimensions

     

     

     

     

    • Width

    mm

    400

    400

    400

    • Height

    mm

    2200

    2200

    2200

    • Depth

    mm

    600

    600

    600

    Weight, approx.

    kg

    350

    350

    350

    Frame size

     

    HXL

    HXL

    HXL

    Short-circuit current rating according to IEC

    kA

    65

    65

    84



    1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 400 V 3 AC 50 Hz.

    2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 460 V 3 AC 60 Hz.

    3) The base-load current IL is based on a load cycle of 110 % for 60 s or 150 % for 10 s with a load cycle duration of 300 s.

    4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

    5)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

    6) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.

    7) The value applies to coolants comprising water and a mixture of water and anti-freeze agent.

    8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.

    9) Total of all motor cables. Longer cable lengths for specific configurations are available on request.For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

     

    Line voltage 380 ... 480 V 3 AC

    DC link voltage 510 ... 720 V DC

    Motor Modules

    6SL3725-1TE41-0AA3

    6SL3725-1TE41-2AA3

    6SL3725-1TE41-4AA3

    6SL3725-1TE41-4AS3 10)

    Type rating

     

     

     

     

     

    • At IL (50 Hz 400 V) 1)

    kW

    560

    710

    800

    800

    • At IH (50 Hz 400 V) 1)

    kW

    450

    630

    710

    630

    • At IL (60 Hz 460 V) 2)

    hp

    800

    1000

    1150

    1000

    • At IH (60 Hz 460 V) 2)

    hp

    700

    900

    1000

    900

    Output current

     

     

     

     

     

    • Rated current Irated O

    A

    985

    1260

    1405

    1330

    • Base-load current IL3)

    A

    960

    1230

    1370

    1310

    • Base-load current IH4)

    A

    860

    1127

    1257

    1150

    • Maximum current Imax O

    A

    1440

    1845

    2055

    2055

    DC link current

     

     

     

     

     

    • Rated current Irated DC
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    1202

    1512

    1714

    1550

    • Active Line Module

    A

    1080

    1361

    1544

    1403

    • Base-load current IL DC 3)
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    1170

    1474

    1670

    1525

    • Active Line Module

    A

    1051

    1326

    1500

    1405

    • Base-load current IH DC 4)
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    1048

    1345

    1532

    1676

    • Active Line Module

    A

    942

    1211

    1377

    1403

    Current demand

     

     

     

     

     

    • 24 V DC auxiliary power supply

    A

    1.46

    1.46

    1.46

    1.46

    • 230 V 1 AC

    A

    0.6

    0.6

    0.6

    0.6

    DC link capacitance

    μF

    21000

    29000

    29000

    21000

    Pulse frequency 5)

     

     

     

     

     

    • Rated frequency

    kHz

    1.25

    1.25

    1.25

    2

    • Pulse frequency, max.

     

     

     

     

     

    • Without current derating

    kHz

    1.25

    1.25

    1.25

    2

    • With current derating

    kHz

    7.5

    7.5

    7.5

    4

    Power loss, max. 6)

    at 50 Hz 400 V

     

     

     

     

     

    • Degree of protection <IP55

     

     

     

     

     

    • Dissipated to coolant

    kW

    7.5

    8.6

    9.5

    10.2

    • Dissipated to ambient air

    kW

    1.0

    1.3

    1.5

    1.4

    • Degree of protection IP55

     

     

     

     

     

    • Dissipated to coolant

    kW

    8.3

    9.6

    10.7

    11.3

    • Dissipated to ambient air

    kW

    0.2

    0.3

    0.3

    0.3

    Coolant volume flow 7)

    all degrees of protection

    l/min

    27

    27

    27

    27

    Liquid volume

    Degree of protection <IP55/IP55

    dm3

    5.2/7

    5.2/7

    5.2/7

    5.2/7

    Pressure drop, max. 8)

    for volume flow

    Pa

    150000

    150000

    150000

    150000

    Heat exchanger material

     

    Aluminum

    Aluminum

    Aluminum

    Aluminum

    Sound pressure level LpA

    (1 m) at 50/60 Hz

    dB

    56

    56

    56

    56

    Motor connection

    U2, V2, W2

     

    2/M12

    2/M12

    2/M12

    2/M12

    • Conductor cross section, max. (IEC)

    mm2

    4 × 240

    4 × 240

    4 × 240

    4 × 240

    PE/GND connection

     

    PE bar

    PE bar

    PE bar

    PE bar

    • Busbar cross-section

    mm2

    600

    600

    600

    600

    • Conductor cross section, max. (IEC)

    mm2

    240

    240

    240

    240

    Cable length, max. 9)

    Shielded/unshielded

    m

    300/450

    300/450

    300/450

    300/450

    Degree of protection (standard version)

     

    IP21

    IP21

    IP21

    IP21

    Dimensions

     

     

     

     

     

    • Width

    mm

    600

    600

    600

    600

    • Height

    mm

    2200

    2200

    2200

    2200

    • Depth

    mm

    600

    600

    600

    600

    Weight, approx.

    kg

    460

    460

    460

    470

    Frame size

     

    JXL

    JXL

    JXL

    JXL

    Short-circuit current rating according to IEC

    kA

    84

    100

    100

    100



    1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 400 V 3 AC 50 Hz.

    2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 460 V 3 AC 60 Hz.

    3) The base-load current IL is based on a load cycle of 110 % for 60 s or 150 % for 10 s with a load cycle duration of 300 s.

    4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

    5)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

    6) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.

    7) The value applies to coolants comprising water and a mixture of water and anti-freeze agent.

    8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.

    9) Total of all motor cables. Longer cable lengths for specific configurations are available on request.For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

    10) This Motor Module has been specifically designed for loads demanding a high dynamic performance. The derating factor kIGBT and the derating characteristics can be ignored (see section "Duty cycles” in the SINAMICS Low Voltage Engineering Manual).

     

    Line voltage 500 ... 690 V 3 AC

    DC link voltage 675 … 1035 V DC

    Motor Modules

    6SL3725-1TG34-7AA3

    6SL3725-1TG35-8AA3

    6SL3725-1TG37-4AA3

    6SL3725-1TG38-0AA3 10)

    Type rating

     

     

     

     

     

    • At IL (50 Hz 690 V) 1)

    kW

    450

    560

    710

    800

    • At IH (50 Hz 690 V) 1)

    kW

    400

    450

    630

    710

    • At IL (50 Hz 500 V) 1)

    kW

    315

    400

    500

    560

    • At IH (50 Hz 500 V) 1)

    kW

    250

    315

    450

    500

    • At IL (60 Hz 575 V) 2)

    hp

    450

    600

    700

    800

    • At IH (60 Hz 575 V) 2)

    hp

    450

    500

    700

    700

    Output current

     

     

     

     

     

    • Rated current Irated O

    A

    465

    575

    735

    810

    • Base-load current IL3)

    A

    452

    560

    710

    790

    • Base-load current IH4)

    A

    416

    514

    657

    724

    • Maximum current Imax O

    A

    678

    840

    1065

    1185

    DC link current

     

     

     

     

     

    • Rated current Irated DC
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    558

    702

    903

    990

    • Active Line Module

    A

    502

    632

    759

    891

    • Base-load current IL DC 3)
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    544

    683

    870

    948

    • Active Line Module

    A

    489

    616

    781

    870

    • Base-load current IH DC 4)
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    496

    627

    795

    885

    • Active Line Module

    A

    446

    565

    732

    808

    Current demand

     

     

     

     

     

    • 24 V DC auxiliary power supply

    A

    1.6

    1.6

    1.6

    1.6

    • 230 V 1 AC

    A

    0.6

    0.6

    0.6

    0.6

    DC link capacitance

    μF

    9670

    9670

    10500

    10500

    Pulse frequency 5)

     

     

     

     

     

    • Rated frequency

    kHz

    1.25

    1.25

    1.25

    1.25

    • Pulse frequency, max.

     

     

     

     

     

    • Without current derating

    kHz

    1.25

    1.25

    1.25

    1.25

    • With current derating

    kHz

    7.5

    7.5

    7.5

    7.5

    Power loss, max. 6)

    at 50 Hz 690 V

     

     

     

     

     

    • Degree of protection <IP55

     

     

     

     

     

    • Dissipated to coolant

    kW

    5.3

    5.5

    7.5

    8.3

    • Dissipated to ambient air

    kW

    0.4

    0.5

    0.6

    0.7

    • Degree of protection IP55

     

     

     

     

     

    • Dissipated to coolant

    kW

    5.6

    5.8

    7.9

    8.8

    • Dissipated to ambient air

    kW

    0.2

    0.2

    0.2

    0.2

    Coolant volume flow 7)

    all degrees of protection

    l/min

    16

    16

    16

    16

    Liquid volume

    Degree of protection <IP55/IP55

    dm3

    3.3/5.1

    3.3/5.1

    3.3/5.1

    3.3/5.1

    Pressure drop, max. 8)

    for volume flow

    Pa

    150000

    150000

    150000

    150000

    Heat exchanger material

     

    Aluminum

    Aluminum

    Aluminum

    Aluminum

    Sound pressure level LpA

    (1 m) at 50/60 Hz

    dB

    54

    54

    54

    54

    Motor connection

    U2, V2, W2

     

    2/M12

    2/M12

    2/M12

    2/M12

    • Conductor cross section, max. (IEC)

    mm2

    4 × 185

    4 × 185

    4 × 185

    4 × 185

    PE/GND connection

     

    PE bar

    PE bar

    PE bar

    PE bar

    • Busbar cross-section

    mm2

    600

    600

    600

    600

    • Conductor cross section, max. (IEC)

    mm2

    240

    240

    240

    240

    Cable length, max. 9)

    Shielded/unshielded

    m

    300/450

    300/450

    300/450

    300/450

    Degree of protection (standard version)

     

    IP21

    IP21

    IP21

    IP21

    Dimensions

     

     

     

     

     

    • Width

    mm

    400

    400

    400

    400

    • Height

    mm

    2200

    2200

    2200

    2200

    • Depth

    mm

    600

    600

    600

    600

    Weight, approx.

    kg

    350

    350

    350

    350

    Frame size

     

    HXL

    HXL

    HXL

    HXL

    Short-circuit current rating according to IEC

    kA

    84

    84

    100

    100



    1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 500 V or 690 V 3 AC 50 Hz.

    2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz.

    3) The base-load current IL is based on a load cycle of 110 % for 60 s or 150 % for 10 s with a load cycle duration of 300 s.

    4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

    5)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

    6) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.

    7) The value applies to coolants comprising water and a mixture of water and anti-freeze agent.

    8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.

    9) Total of all motor cables. Longer cable lengths for specific configurations are available on request.For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

    10) The device is optimized for a base pulse frequency of 1.25 kHz, for an increased pulse frequency – or for certain overloads the derating factor is higher than that for the device with article number 6SL3325‑1TG38‑1AAx.

     

    Line voltage 500 ... 690 V 3 AC

    DC link voltage 675 … 1035 V DC

    Motor Modules

    6SL3725-1TG38-1AA3

    6SL3725-1TG41-0AA3

    6SL3725-1TG41-3AA3

    6SL3725-1TG41-6AA3

    Type rating

     

     

     

     

     

    • At IL (50 Hz 690 V) 1)

    kW

    800

    1000

    1200

    1500

    • At IH (50 Hz 690 V) 1)

    kW

    710

    900

    1000

    1260

    • At IL (50 Hz 500 V) 1)

    kW

    560

    710

    900

    1000

    • At IH (50 Hz 500 V) 1)

    kW

    560

    630

    800

    900

    • At IL (60 Hz 575 V) 2)

    hp

    800

    1000

    1250

    1500

    • At IH (60 Hz 575 V) 2)

    hp

    700

    900

    1000

    1250

    Output current

     

     

     

     

     

    • Rated current Irated O

    A

    810

    1025

    1270

    1560

    • Base-load current IL3)

    A

    790

    1000

    1230

    1500

    • Base-load current IH4)

    A

    724

    917

    1136

    1284

    • Maximum current Imax O

    A

    1185

    1500

    1845

    2055

    DC link current

     

     

     

     

     

    • Rated current Irated DC
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    990

    1250

    1550

    1903

    • Active Line Module

    A

    891

    1125

    1395

    1605

    • Base-load current IL DC 3)
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    963

    1219

    1500

    1800

    • Active Line Module

    A

    869

    1100

    1353

    1650

    • Base-load current IH DC 4)
      when supplied via

     

     

     

     

     

    • Basic Line Module

    A

    883

    1118

    1384

    1680

    • Active Line Module

    A

    796

    1009

    1250

    1550

    Current demand

     

     

     

     

     

    • 24 V DC auxiliary power supply

    A

    1.46

    1.46

    1.46

    1.46

    • 230 V 1 AC

    A

    0.6

    0.6

    0.6

    0.6

    DC link capacitance

    μF

    14000

    16000

    19330

    21000

    Pulse frequency 5)

     

     

     

     

     

    • Rated frequency

    kHz

    1.25

    1.25

    1.25

    1.25

    • Pulse frequency, max.

     

     

     

     

     

    • Without current derating

    kHz

    1.25

    1.25

    1.25

    1.25

    • With current derating

    kHz

    7.5

    7.5

    7.5

    7.5

    Power loss, max. 6)

    at 50 Hz 690 V

     

     

     

     

     

    • Degree of protection <IP55

     

     

     

     

     

    • Dissipated to coolant

    kW

    9.0

    10.0

    12.9

    17.1

    • Dissipated to ambient air

    kW

    1.1

    1.2

    1.4

    1.6

    • Degree of protection IP55

     

     

     

     

     

    • Dissipated to coolant

    kW

    9.8

    11.2

    14.0

    18.4

    • Dissipated to ambient air

    kW

    0.3

    0.3

    0.3

    0.3

    Coolant volume flow 7)

    all degrees of protection

    l/min

    27

    27

    27

    27

    Liquid volume

    Degree of protection <IP55/IP55

    dm3

    5.2/7

    5.2/7

    5.2/7

    5.2/7

    Pressure drop, max. 8)

    for volume flow

    Pa

    150000

    150000

    150000

    150000

    Heat exchanger material

     

    Aluminum

    Aluminum

    Aluminum

    Aluminum

    Sound pressure level LpA

    (1 m) at 50/60 Hz

    dB

    56

    56

    56

    56

    Motor connection

    U2, V2, W2

     

    2/M12

    2/M12

    2/M12

    2/M12

    • Conductor cross section, max. (IEC)

    mm2

    4 × 240

    4 × 240

    4 × 240

    4 × 240

    PE/GND connection

     

    PE bar

    PE bar

    PE bar

    PE bar

    • Busbar cross-section

    mm2

    600

    600

    600

    600

    • Conductor cross section, max. (IEC)

    mm2

    240

    240

    240

    240

    Cable length, max. 9)

    Shielded/unshielded

    m

    300/450

    300/450

    300/450

    300/450

    Degree of protection (standard version)

     

    IP21

    IP21

    IP21

    IP21

    Dimensions

     

     

     

     

     

    • Width

    mm

    600

    600

    600

    600

    • Height

    mm

    2200

    2200

    2200

    2200

    • Depth

    mm

    600

    600

    600

    600

    Weight, approx.

    kg

    460

    460

    460

    470

    Frame size

     

    JXL

    JXL

    JXL

    JXL

    Short-circuit current rating according to IEC

    kA

    100

    100

    100

    100



    1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 500 V or 690 V 3 AC 50 Hz.

    2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz.

    3) The base-load current IL is based on a load cycle of 110 % for 60 s or 150 % for 10 s with a load cycle duration of 300 s.

    4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

    5)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual.

    6) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.

    7) The value applies to coolants comprising water and a mixture of water and anti-freeze agent.

    8) The value is valid for water as coolant. Additional information and notes on other coolants is provided in the SINAMICS Low Voltage Engineering Manual.

    9) Total of all motor cables. Longer cable lengths for specific configurations are available on request.For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.