Товаров
  
корзина пуста
  • Каталог оборудования Siemens

FM 450-1 counter module

  • Заказные данные
    (1)
  • Аксессуары
    (6)
  • Информационные материалы

    Информационные материалы

    • Two-channel intelligent counter module for simple counting tasks
    • For direct connection of incremental encoders
    • Comparison function with 2 specifiable comparison values
    • Integrated digital outputs for outputting the response when the comparison values are reached

    Note

    SIMODRIVE Sensor/Motion Connect 500 feature incremental encoders and preassembled connecting cables for counting and positioning functions.

    http://www.siemens.com/simatic-technology

    Область применения

    The FM 450-1 is the intelligent, single-channel counter module for simple counting tasks. It can be used in the SIMATIC S7-400.

    Applications include:

    • Assembly and handling equipment
    • Plastics machines
    • Production machines
    • Paper machines
    • Textiles machines
    • Packaging machines

    Дизайн

    The FM 450-1 supplies power for the encoders.

    The module is characterized by the following mechanical features:

    • Compact configuration:
      The rugged plastic housing contains:
      • Fault LEDs (INTF/EXTF)
      • LEDs to indicate the counter is running (CR), and the counting direction (DIR)
      • LEDs for digital input and output modules
      • Front connector as on the signal modules
      • Labeling area on the front cover.
    • Easy installation:
      The module is simply mounted in the rack and screwed tight. It can be fitted with a coding element in the front connector.
    • User-friendly wiring:
      The module is wired by means of a plug-in front connector. When the connector is plugged in for the first time a coding element in the module engages, so that the connector can only be plugged into modules of the same type. When the module is replaced, the front connector can be used in its fully wired state for the new module of the same type.
    Configuring package

    The configuring package required for configuration comprises:

    • Manual
    • Parameterization screen forms
    • Standard function blocks for data exchange with the CPU

    Функции

    The module off-loads the CPU by:

    • Direct connection of one incremental encoder per channel
    • Direct connection for gate signals (light barrier, etc.) using integrated digital inputs
    • A comparison function and output of response via integrated digital output modules

    The following functions are provided:

    • Two channels for upcounting and downcounting; each 32-bit
    • Counting frequency up to 500 kHz (RS 422 encoders)
    • Counting range 0 to 32 bit or ±31 bit, as desired
    • One-time or periodic counting process
    • Single, double or quadruple evaluation
    • Can be connected to incremental encoders; e.g., initiators, 24 V encoders or RS 422 encoders (5 V)
    • Gate control via levels
    • Setting via the digital input
    • Counter can be loaded with a predefined starting value
    • Comparison function using two user-definable reference values
    • Interrupt response when a reference value is reached, zero crossing, range overrun (selectable)
    • Output signal (24-V level), controlled by the comparison functions: with jointly specifiable pulse duration or as a continuous signal from the comparison value to the limit of the counting range.

    Standard Function Blocks

     

    CNT_CTRL (FC 0)

    Controls the counters of the FM 450-1

    DIAG_INF (FC 1)

    For providing the diagnostic information of the FM 450-1



    Mode of operation

    The FM 450-1 counter module detects pulses from incremental encoders at up to 500 kHz, as a function of directly connectable gate signals. It analyzes the direction of the pulses and compares independently on each channel the respective actual values with two specifiable comparison values.

    There are two possibilities available to output the reaction to the process:

    • Digital outputs:
      These can be configured via a common register with a selectable minimum pulse or with level switching.
    • Backplane bus:
      the FM 450-1 can send an interrupt to the CPU via the integrated backplane bus.

    Operating Modes

     

    Continuous counting

    After the gate is enabled, endless counting takes place between the lower and upper count limit from the starting value

    One-shot counting

    Depending on the main counting direction and beginning with the start value, there is one-shot counting up to the upper or lower range limit after the gate is enabled.

    • Main counting direction up: From 0 to the programmable range limit.
    • Main counting direction down: From the programmable start value to 0.

    Periodic counting

    After the gate is enabled, periodic counting takes place from the starting value within the programmed counting range depending on the main count direction.

    • Main counting direction up: Periodically from 0 to the programmable upper range limit -1.
    • Main counting direction down: Periodically from the programmed start value to 1.


    Parameterization

    Parameters are assigned with STEP 7 taking into account the parameterization screen forms. A configuring package is available for this purpose.

    Технические данные

    Order number

    6ES7450-1AP01-0AE0

    FM 450-1, COUNTER MODULE, 2 CHANNELS

    Supply voltage

     

    Load voltage 1L+

     

    • Reverse polarity protection

    Yes

    Load voltage 2L+

     

    • Reverse polarity protection

    Yes

    Auxiliary voltage 1L+, load voltage 2L+

     

    • Rated value (DC)

    24 V

    • permissible range, lower limit (DC)

    20.4 V; Dynamic 18.5 V

    • permissible range, upper limit (DC)

    28.8 V; dynamic 30.2 V

    non-periodic skip

     

    • Duration

    500 ms

    • Recovery time

    50 s

    • Value

    35 V

    Input current

     

    from load voltage 1L+ (without load), max.

    50 mA

    from load voltage 2L+ (without load), max.

    60 µA

    from backplane bus 5 V DC, max.

    300 mA

    Encoder supply

     

    5 V encoder supply

     

    • 5 V

    Yes; 5.2 V +/-2%

    • short-circuit protection

    Yes

    • Output current, max.

    300 mA

    24 V encoder supply

     

    • 24 V

    Yes; 1L+ (-3 V)

    • Short-circuit protection

    Yes

    • Output current, max.

    300 mA

    Power loss

     

    Power loss, typ.

    6 W

    Digital inputs

     

    Number of digital inputs

    6

    Functions

    1 for gate start, 1 for gate stop, 1 for setting the counter

    Input voltage

     

    • for signal "0"

    -28.8 ... +5V

    • for signal "1"

    +11 to +28.8V

    Input current

     

    • for signal "1", typ.

    9 mA

    Input delay (for rated value of input voltage)

     

    • Input frequency (with a time delay of 0.1 ms), max.

    200 kHz

    for standard inputs

     

    • parameterizable

    Yes

    • at "0" to "1", max.

    2.5 µs; >= 2.5 µs (200 kHz); <= 25 µs (20 kHz)

    Digital outputs

     

    Number of digital outputs

    4

    Short-circuit protection

    Yes; Clocked electronically

    Limitation of inductive shutdown voltage to

    2L+ (-39 V)

    Output voltage

     

    • for signal "0", max.

    3 V

    • for signal "1", min.

    2L+ (-1,5 V)

    Output current

     

    • for signal "1" rated value

    0.5 A; Res. / P.D. 5 W tungsten 24 V DC

    • for signal "1" permissible range for 0 to 60 °C, min.

    5 mA

    • for signal "1" permissible range for 0 to 60 °C, max.

    0.6 A

    Output delay with resistive load

     

    • "0" to "1", max.

    300 µs

    Encoder

     

    Connectable encoders

     

    • Incremental encoder (symmetrical)

    Yes; With 2 pulse trains offset by 90°

    • Incremental encoder (asymmetrical)

    Yes

    • 24 V initiator

    Yes

    • 24 V directional element

    Yes; 1 pulse train, 1 direction level

    Counter

     

    Number of counter inputs

    2; 32 bit or ±31 bit

    Counter input 5 V

     

    • Type

    RS 422

    • Terminating resistor

    220 Ω

    • Differential input voltage

    min. 0.5 V

    • Counting frequency, max.

    500 kHz

    Counter input 24 V

     

    • Input voltage for signal "0"

    -30 to +5V

    • Input voltage for signal "1"

    +11 to +30V

    • Input current for signal "1", typ.

    9 mA

    • Counting frequency, max.

    200 kHz

    • Minimum pulse width

    >= 2.5 µs (200 kHz); <= 25 µs (20 kHz) (parameterizable)

    Parameter

     

    Remark

    Assigned binary addresses: 64 bytes/64 bytes

    Potential separation

     

    Potential separation digital inputs

     

    • between the channels and backplane bus

    Yes; Optocoupler

    Potential separation digital outputs

     

    • between the channels and backplane bus

    Yes; Optocoupler

    Potential separation counter

     

    • between the channels and backplane bus

    Yes; Optocoupler

    Permissible potential difference

     

    between different circuits

    75 V DC/60 V AC

    Isolation

     

    Isolation tested with

    500 V

    Connection method

     

    required front connector

    1x 48-pin

    Dimensions

     

    Width

    25 mm

    Height

    290 mm

    Depth

    210 mm

    Weights

     

    Weight, approx.

    650 g


    Дальнейшая информация

    Brochures

    Information material for downloading can be found in the Internet:

    http://www.automation.siemens.com/infocenter