Safe Brake Relay for blocksize format

  • Заказные данные
    (1)
  • Информационные материалы

    Информационные материалы

    Safe Brake Relay

    With the Safe Brake Relay, the brake is controlled in accordance with IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3.

    Дизайн

    The Safe Brake Relay can be installed below the Power Module on the shield connection plate.

    The Safe Brake Relay has the following connections and interfaces:

    • 1 two-channel transistor output stage to control the motor brake solenoid
    • 1 connection for the cable harness (CTRL) to the Power Module in blocksize format
    • 1 connection for the 24 V DC power supply

    The connection between the 24 V DC supply and the Safe Brake Relay must be kept as short as possible.

    The scope of supply of a Safe Brake Relay includes the following:

    • 2 cable harnesses for connecting to the CTRL socket of the Power Module
      • Length 0.32 m (1.05 ft) for frame sizes FSA to FSC
      • Length 0.55 m (1.80 ft) for frame sizes FSD to FSF

    Интеграция

    Connection example of a Safe Brake Relay

    The 24 V DC solenoid of the motor brake is directly connected to the Safe Brake Relay. External overvoltage limiters are not required.

    Технические данные

     

    Safe Brake Relay

    6SL3252-0BB01-0AA0

    Power supply

    20.4 ... 28.8 V DC

    Recommended rated supply voltage 26 V DC

    (to compensate for voltage drop in feeder cable to 24 V DC motor brake solenoid)

    Current requirement, max.

     

    • Motor brake

    2 A

    • At 24 V DC

    0.05 A + the current requirement of motor brake

    Conductor cross-section, max.

    2.5 mm2

    Dimensions

     

    • Width

    69 mm (2.72 in)

    • Height

    63 mm (2.48 in)

    • Depth

    33 mm (1.30 in)

    Weight, approx.