Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS S7-1200 SB 1223 RAIL

  • Заказные данные
    (1)
  • Информационные материалы

    Информационные материалы

    • Digital inputs and outputs as supplement to the integral I/O of the SIPLUS S7-1200-CPUs
    • Approved in accordance with the railway standards EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 for use in rail traffic
    • Can be plugged directly into the CPU

    Область применения

    The SB 1223 digital input/output signal board permits:

    • Connection of the controller to digital signals of the process
    • Output of digital signals from the controller to the process.

    Дизайн

    The signal boards are plugged directly into the receptacle on the front of each S7-1200 CPU.

    • Mounting:
      Signal boards are plugged directly into the SIMATIC S7-1200 CPU and are thus electrically and mechanically connected to the CPU
    • The CPU mounting dimensions remain unchanged
    • All signal boards are easy to replace thanks to removable connecting terminals ("independent wiring")

    Функции

    The SB 1223 digital input/output signal board converts

    • the level of the external digital signals from the process into the internal signal level of the S7-1200 and
    • the internal signal level of the S7-1200 into the external signal level required by the process

    Технические данные

    Order number

    6AG2223-0BD30-1XB0

    SIPLUS S7-1200 SB 1223 2DI/2DQ RAIL

    General information

     

    Product type designation

    SB 1223 DI2x24 VDC, DQ 2x24 VDC

    Supply voltage

     

    permissible range, lower limit (DC)

    20.4 V

    permissible range, upper limit (DC)

    28.8 V

    Input current

     

    from backplane bus 5 V DC, typ.

    50 mA

    Output voltage

     

    Power supply to the transmitters

     

    • Supply current, max.

    4 mA; per channel

    Power loss

     

    Power loss, typ.

    1 W

    Digital inputs

     

    Number of digital inputs

    2; Current-sinking

    • in groups of

    1

    Input characteristic curve in accordance with IEC 61131, type 1

    Yes

    Number of simultaneously controllable inputs

     

    all mounting positions

     

    • up to 40 °C, max.

    2

    Input voltage

     

    • Type of input voltage

    DC

    • Rated value (DC)

    24 V

    • for signal "0"

    0 to 5 V

    • for signal "1"

    +15 to +30V

    Input current

     

    • for signal "0", max. (permissible quiescent current)

    1 mA

    • for signal "1", typ.

    0.5 A

    Input delay (for rated value of input voltage)

     

    for standard inputs

     

    • parameterizable

    Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four

    • at "0" to "1", max.

    2 µs

    • at "1" to "0", max.

    10 µs

    for interrupt inputs

     

    • parameterizable

    Yes

    for counter/technological functions

     

    • parameterizable

    Yes

    Cable length

     

    • shielded, max.

    500 m

    • unshielded, max.

    300 m

    Digital outputs

     

    Number of digital outputs

    2; MOSFET, solid-state (current-sinking/current-sourcing)

    • in groups of

    1

    Short-circuit protection

    No

    Switching capacity of the outputs

     

    • with resistive load, max.

    0.5 A

    • on lamp load, max.

    5 W

    Load resistance range

     

    • upper limit

    0.6 Ω

    Output voltage

     

    • Rated value (DC)

    24 V

    • for signal "0", max.

    0.1 V; with 10 kOhm load

    • for signal "1", min.

    20 V

    Output current

     

    • for signal "1" rated value

    0.5 A

    • for signal "0" residual current, max.

    10 µA

    Cable length

     

    • shielded, max.

    500 m

    • unshielded, max.

    150 m

    Interrupts/diagnostics/status information

     

    Alarms

    Yes

    Diagnostic functions

    Yes

    Diagnostics indication LED

     

    • for status of the inputs

    Yes

    • for status of the outputs

    Yes

    Isolation

     

    Isolation tested with

    According to EN 50155 (routine test)

    Degree and class of protection

     

    Degree of protection acc. to EN 60529

    • IP20

    Yes

    Standards, approvals, certificates

     

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Free fall

     

    • Fall height, max.

    0.3 m; five times, in product package

    Ambient temperature during operation

     

    • min.

    -25 °C; = Tmin; Startup @ -25 °C

    • max.

    55 °C; = Tmax; +70 °C for 10 minutes (T1 acc. to EN 50155) for horizontal mounting position

    Ambient temperature during storage/transportation

     

    • min.

    -40 °C

    • max.

    70 °C

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Mechanics/material

     

    Enclosure material (front)

    • Plastic

    Yes

    Dimensions

     

    Width

    38 mm

    Height

    62 mm

    Depth

    21 mm

    Weights

     

    Weight, approx.

    40 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776