Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS S7-1200 SM 1221 RAIL

  • Заказные данные
    (1)
  • Информационные материалы

    Информационные материалы

    • Digital inputs as supplement to the integral I/O of the CPUs
    • Approved in accordance with the railway standards EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 for use in rail traffic
    • For flexible adaptation of the controller to the corresponding task
    • For subsequent expansion of the system with additional inputs

    Область применения

    Digital input modules allow the connection of the controller to digital signals of the process.

    This provides users with the following advantages:

    • Optimum adaptation:
      with signal modules which can be mixed as desired, users can adapt their controllers exactly to the relevant task. This avoids superfluous investments.
    • Flexibility:
      if the task is expanded subsequently, the controller can be upgraded. Updating of the user program is extremely simple.

    Функции

    The SM 1221 digital input signal modules convert the level of the external digital signals from the process into the internal signal level of the S7-1200.

    Технические данные

    Order number

    6AG2221-1BF32-1XB0

    SIPLUS S7-1200 SM 1221 8DI RAIL

    General information

     

    Product type designation

    SM 1221 DI 8x24 VDC

    Supply voltage

     

    Rated value (DC)

    • 24 V DC

    Yes

    permissible range, lower limit (DC)

    20.4 V

    permissible range, upper limit (DC)

    28.8 V

    Input current

     

    from backplane bus 5 V DC, max.

    105 mA

    Digital inputs

     

    • from load voltage L+ (without load), max.

    4 mA; per channel

    Output voltage

     

    Power supply to the transmitters

     

    • present

    Yes

    Power loss

     

    Power loss, typ.

    1.5 W

    Digital inputs

     

    Number of digital inputs

    8

    • in groups of

    2

    Input characteristic curve in accordance with IEC 61131, type 1

    Yes

    Number of simultaneously controllable inputs

     

    all mounting positions

     

    • up to 40 °C, max.

    8

    horizontal installation

     

    • up to 40 °C, max.

    8

    • up to 50 °C, max.

    8

    vertical installation

     

    • up to 40 °C, max.

    8

    Input voltage

     

    • Type of input voltage

    DC

    • Rated value (DC)

    24 V

    • for signal "0"

    5 V DC at 1 mA

    • for signal "1"

    15 V DC at 2.5 mA

    Input current

     

    • for signal "0", max. (permissible quiescent current)

    1 mA

    • for signal "1", min.

    2.5 mA

    • for signal "1", typ.

    4 mA

    Input delay (for rated value of input voltage)

     

    for standard inputs

     

    • parameterizable

    Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four

    for interrupt inputs

     

    • parameterizable

    Yes

    Cable length

     

    • shielded, max.

    500 m

    • unshielded, max.

    300 m

    Interrupts/diagnostics/status information

     

    Alarms

    Yes

    Diagnostic functions

    Yes

    Alarms

     

    • Diagnostic alarm

    Yes

    Diagnostic messages

     

    • Monitoring the supply voltage

    Yes

    Diagnostics indication LED

     

    • for status of the inputs

    Yes

    • for maintenance

    Yes

    • Status indicator digital input (green)

    Yes

    Potential separation

     

    Potential separation digital inputs

     

    • between the channels, in groups of

    2

    Isolation

     

    Isolation tested with

    According to EN 50155 (routine test)

    Degree and class of protection

     

    Degree of protection acc. to EN 60529

    • IP20

    Yes

    Standards, approvals, certificates

     

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Free fall

     

    • Fall height, max.

    0.3 m; five times, in product package

    Ambient temperature during operation

     

    • min.

    -25 °C; = Tmin; Startup @ -25 °C

    • max.

    60 °C; = Tmax; +70 °C for 10 minutes (T1 acc. to EN 50155) for horizontal mounting position

    Ambient temperature during storage/transportation

     

    • min.

    -40 °C

    • max.

    70 °C

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Connection method

     

    required front connector

    Yes

    Mechanics/material

     

    Enclosure material (front)

    • Plastic

    Yes

    Dimensions

     

    Width

    45 mm

    Height

    100 mm

    Depth

    75 mm

    Weights

     

    Weight, approx.

    170 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776