Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS S7-1200 SM 1223 RAIL

  • Заказные данные
    (2)
  • Информационные материалы

    Информационные материалы

    • Digital inputs and outputs as supplement to the integral I/O of the CPUs
    • Approved in accordance with the railway standards EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 for use in rail traffic
    • For flexible adaptation of the controller to the corresponding task
    • For subsequent expansion of the system with additional inputs and outputs

    Область применения

    Digital input/output modules permit:

    • Connection of the controller to digital signals of the process
    • Output of digital signals from the controller to the process.

    This provides users with the following advantages:

    • Optimum adaptation:
      with signal modules which can be mixed as desired, users can adapt their controllers exactly to the relevant task. This avoids superfluous investments. Modules with 8 and 16 input/output channels are available.
    • Flexibility:
      if the task is expanded subsequently, the controller can be upgraded. Updating of the user program is extremely simple.

    Функции

    The SM 1223 digital input/output signal modules convert

    • the level of the external digital signals from the process into the internal signal level of the S7-1200 and
    • the internal signal level of the S7-1200 into the external signal level required by the process.

    Технические данные

    Order number

    6AG2223-1BH32-1XB0

    6AG2223-1PL32-1XB0

    SIPLUS S7-1200 SM 1223 8DI/8DQ RAIL

    SIPLUS S7-1200 SM 1223 16DI/16DQ RAIL

    General information

     

     

    Product type designation

    SM 1223 DI 8x24 VDC, DQ 8x24 VDC

    SM 1223 DI 16x24 VDC, DQ 16xRelay

    Supply voltage

     

     

    Rated value (DC)

    • 24 V DC

    Yes

    Yes

    permissible range, lower limit (DC)

    20.4 V

    20.4 V

    permissible range, upper limit (DC)

    28.8 V

    28.8 V

    Input current

     

     

    from backplane bus 5 V DC, max.

    145 mA

    180 mA

    Digital inputs

     

     

    • from load voltage L+ (without load), max.

    4 mA; per channel

    4 mA/input 11 mA/relay

    Output voltage

     

     

    Power supply to the transmitters

     

     

    • present

    Yes

    Yes

    Power loss

     

     

    Power loss, typ.

    2.5 W

    10 W

    Digital inputs

     

     

    Number of digital inputs

    8

    16

    • in groups of

    2

    2

    Input characteristic curve in accordance with IEC 61131, type 1

    Yes

    Yes

    Number of simultaneously controllable inputs

     

     

    all mounting positions

     

     

    • up to 40 °C, max.

    8

    16

    horizontal installation

     

     

    • up to 40 °C, max.

    8

    16

    • up to 50 °C, max.

    8

    16

    vertical installation

     

     

    • up to 40 °C, max.

    8

    16

    Input voltage

     

     

    • Type of input voltage

    DC

    DC

    • Rated value (DC)

    24 V

    24 V

    • for signal "0"

    5 V DC at 1 mA

    5 V DC at 1 mA

    • for signal "1"

    15 V DC at 2.5 mA

    15 V DC at 2.5 mA

    Input current

     

     

    • for signal "0", max. (permissible quiescent current)

    1 mA

    1 mA

    • for signal "1", min.

    2.5 mA

    2.5 mA

    • for signal "1", typ.

    4 mA

    4 mA

    Input delay (for rated value of input voltage)

     

     

    for standard inputs

     

     

    • parameterizable

    Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four

    Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four

    for interrupt inputs

     

     

    • parameterizable

    Yes

    Yes

    Cable length

     

     

    • shielded, max.

    500 m

    500 m

    • unshielded, max.

    300 m

    300 m

    Digital outputs

     

     

    Number of digital outputs

    8

    16

    • in groups of

    1

    4

    Short-circuit protection

    No; to be provided externally

    No; to be provided externally

    Limitation of inductive shutdown voltage to

    L+ (-48 V)

    Switching capacity of the outputs

     

     

    • with resistive load, max.

    0.5 A

    2 A

    • on lamp load, max.

    5 W

    30 W with DC, 200 W with AC

    Output voltage

     

     

    • Rated value (DC)

    24 V

    5 V DC to 30 V DC

    • Rated value (AC)

    5 V AC to 250 V AC

    • for signal "0", max.

    0.1 V; with 10 kOhm load

    • for signal "1", min.

    20 V DC

    Output current

     

     

    • for signal "1" permissible range, max.

    0.5 A

    2 A

    • for signal "0" residual current, max.

    10 µA

    Output delay with resistive load

     

     

    • "0" to "1", max.

    50 µs

    10 ms

    • "1" to "0", max.

    200 µs

    10 ms

    Total current of the outputs (per group)

     

     

    horizontal installation

     

     

    • up to 50 °C, max.

    4 A; Current per mass

    8 A; Current per mass

    Relay outputs

     

     

    • Number of relay outputs

    16

    • Rated supply voltage of relay coil L+ (DC)

    24 V

    • Number of operating cycles, max.

    mechanically 10 million, at rated load voltage 100 000

    Switching capacity of contacts

     

     

    • with inductive load, max.

    0.5 A

    2 A

    • on lamp load, max.

    5 W

    30 W with DC, 200 W with AC

    • with resistive load, max.

    0.5 A

    2 A

    Cable length

     

     

    • shielded, max.

    500 m

    500 m

    • unshielded, max.

    150 m

    150 m

    Interrupts/diagnostics/status information

     

     

    Alarms

    Yes

    Yes

    Diagnostic functions

    Yes

    Yes

    Alarms

     

     

    • Diagnostic alarm

    Yes

    Yes

    Diagnostic messages

     

     

    • Monitoring the supply voltage

    Yes

    Yes

    Diagnostics indication LED

     

     

    • for status of the inputs

    Yes

    Yes

    • for status of the outputs

    Yes

    Yes

    • for maintenance

    Yes

    Yes

    • Status indicator digital input (green)

    Yes

    Yes

    • Status indicator digital output (green)

    Yes

    Yes

    Potential separation

     

     

    Potential separation digital inputs

     

     

    • between the channels, in groups of

    2

    2

    Potential separation digital outputs

     

     

    • between the channels

    Relays

    • between the channels, in groups of

    1

    4

    • between the channels and backplane bus

    500 V AC

    1500 V AC for 1 minute

    Permissible potential difference

     

     

    between different circuits

    750 V AC for 1 minute

    Isolation

     

     

    Isolation tested with

    According to EN 50155 (routine test)

    According to EN 50155 (routine test)

    Degree and class of protection

     

     

    Degree of protection acc. to EN 60529

    • IP20

    Yes

    Yes

    Standards, approvals, certificates

     

     

    Railway application

     

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

    Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

     

    Free fall

     

     

    • Fall height, max.

    0.3 m; five times, in product package

    0.3 m; five times, in product package

    Ambient temperature during operation

     

     

    • min.

    -25 °C; = Tmin; Startup @ -25 °C

    -25 °C; = Tmin; Startup @ -25 °C

    • max.

    60 °C; = Tmax; +70 °C for 10 minutes (T1 acc. to EN 50155) for horizontal mounting position

    60 °C; Number of simultaneously activated outputs: 8 (no adjacent points) at 60 °C horizontal, 16 at 55 °C horizontal; +70 °C for 10 minutes (T1 acc. to EN 50155)

    • permissible temperature change

    5°C to 55°C, 3°C / minute

    Ambient temperature during storage/transportation

     

     

    • min.

    -40 °C

    -40 °C

    • max.

    70 °C

    70 °C

    Extended ambient conditions

     

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Connection method

     

     

    required front connector

    Yes

    Yes

    Mechanics/material

     

     

    Enclosure material (front)

    • Plastic

    Yes

    Yes

    Dimensions

     

     

    Width

    45 mm

    70 mm

    Height

    100 mm

    100 mm

    Depth

    75 mm

    75 mm

    Weights

     

     

    Weight, approx.

    210 g

    350 g

    Other

     

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776