Active Interface Modules

  • Информационные материалы

    Информационные материалы

    Active Interface Modules are used in combination with Active Line Modules in chassis format. Active Interface Modules contain a Clean Power Filter with basic interference suppression, the pre-charging circuit for the Active Line Module, the line supply voltage sensing circuit and monitoring sensors. The bypass contactor is an integral component in frame sizes FI and GI, which ensures a highly compact design.

    The vast majority of line harmonics are suppressed by the Clean Power Filter.

    The scope of supply of the Active Interface Modules includes:

    • Frame size FI:
      • 0.60 m (1.97 ft) DRIVE-CLiQ cable for connection between Active Interface Module and Active Line Module
      • 1.45 m (4.76 ft) DRIVE-CLiQ cable for connection between Control Unit or SINUMERIK NCU and first Motor Module
    • Frame size GI:
      • 0.95 m (3.12 ft) DRIVE-CLiQ cable for connection between Active Interface Module and Active Line Module
      • 1.45 m (4.76 ft) DRIVE-CLiQ cable for connection between Control Unit or SINUMERIK NCU and first Motor Module

    Технические данные

    Line voltage 380 … 480 V 3 AC

    Active Interface Module in chassis format

     

    6SL3300-7TE32-6AA0

    6SL3300-7TE33-8AA0

    6SL3300-7TE35-0AA0

    Rated current

    A

    210

    260

    380

    490

    Bypass connector

     

    Included

    Included

    Included

    Included

    DC link capacitance

    Of drive line-up, max.

    μF

    41600

    41600

    76800

    76800

    Power requirement

     

     

     

     

     

    • 24 V DC electronic power supply, max.

    A

    0.17

    0.17

    0.17

    0.17

    • Fan supply at 230 V 2 AC, 50/60 Hz, max.

    A

    0.45/0.6

    0.45/0.6

    0.9/1.2

    0.9/1.2

    Power loss

    kW

    2.1

    2.2

    3.0

    3.9

    Cooling air requirement

    m3/s (ft3/s)

    0.24 (8.5)

    0.24 (8.5)

    0.47 (16.6)

    0.47 (16.6)

    Sound pressure level 1)

    LpA (1 m) at 50/60 Hz

    dB

    74/76

    75/77

    76/78

    76/78

    Line/load connection

    L1, L2, L3 / U2, V2, W2

     

    Flat connector for M10 screw

    Flat connector for M10 screw

    Flat connector for M10 screw

    Flat connector for M10 screw

    • Conductor cross-section, max.

    mm2

    2 × 185

    2 × 185

    2 × 185

    2 × 185

    PE connection

     

    M10 screw

    M10 screw

    M10 screw

    M10 screw

    • Conductor cross-section, max.

    mm2

    2 × 185

    2 × 185

    2 × 185

    2 × 185

    Degree of protection

     

    IP20

    IP20

    IP20

    IP20

    Dimensions

     

     

     

     

     

    • Width

    mm (in)

    325 (12.8)

    325 (12.8)

    325 (12.8)

    325 (12.8)

    • Height

    mm (in)

    1400 (55.12)

    1400 (55.12)

    1533 (60.35)

    1533 (60.35)

    • Depth

    mm (in)

    355 (13.98)

    355 (13.98)

    544 (21.42)

    544 (21.42)

    Frame size

     

    FI

    FI

    GI

    GI

    Net weight

    kg (lb)

    135 (298)

    135 (298)

    190 (419)

    190 (419)

    Approvals, according to

     

    cURus

    cURus

    cURus

    cURus

    Suitable for Active Line Module in chassis format

    Type

    6SL3330-7TE32-1AA3

    6SL3330-7TE32-6AA3

    6SL3330-7TE33-8AA3

    6SL3330-7TE35-0AA3

    • Rated power of the Active Line Module

    kW (HP)

    132 (200)

    160 (225)

    235 (350)

    300 (450)



    1) Total sound pressure level of Active Interface Module and Active Line Module.