Товаров
  
корзина пуста
  • Каталог оборудования Siemens

Dummy

  • Заказные данные
    (7)
  • Информационные материалы

    Информационные материалы

    This dummy node must not be released!

    It is used for entering new order numbers for nodes with product selectors.

    Дальнейшая информация

    Sensors (switch block)

    Type

    3SE6 60.-1BA

    3SE6 60.-2BA

    3SE6 60.-3BA

    Design

    M30

    25 mm x 88 mm

    25 mm x 33 mm

    Standards

    IEC 60947-5-3
    (in combination with monitoring unit or AS-Interface)

    Type of operation

    Magnetic

    Operating voltage

    100 V AC/DC

    100 V AC/DC

    24 V DC

    Operational current

    400 mA

    400 mA

    100 mA

    Power

    10 VA/W

    10 VA/W

    1 W

    Max. switching frequency

    5 Hz

    Max. switching interval SONSOFF

    5 … 15 mm

    5 … 15 mm

    4 … 14 mm

    Enclosures

    Thermoplast, glass-fiber reinforced

    Degree of protection according to IEC 60529

    IP67

    Ambient temperature

     
    • Operation

    –25 ... +70 °C

    • Storage, transport

    –25 ... +70 °C

    Shock resistance

    10 g / 11 ms

    Vibration resistance

    10 ... 55 Hz, amplitude 1 mm

    Connection

       
    • With connecting cable

    LiYY 4 × 0.25 mm², length 3 m

    LiYY 4 × 0.25 mm², length 1 m

    LiYY 4 × 0.25 mm², length 3 m

    • With plug

    M12

    M8

    • max. cable length

    1000 m

    1000 m

    100 m



    Safety relay

    Type

    3SE6 806-2CD00

    Standards

    EN 954-1, EN 1088

    Rated control supply voltageUs

    24 V DC

    • Operating range

    0.85 ... 1.2 x Us

    Rated power
    (without signaling circuits Y1 ... Y6)

    3 W

    Max. load current

     
    • Signaling circuits Y1 ... Y6

    20 mA

    • Signaling circuit 31, 32

    2 A

    Inputs

    6 sensors (1 NO or 1 NC)

    Outputs

    6 signal outputs,
    1 relay output,
    2 enabling circuits

    Response time, typ.

     
    • Automatic start

    150 ms

    • Manual start

    25 ms

    Release time, max.

    20 ms

    Recovery time

    350 ms

    Switching capacity
    Enabling circuits 13, 14, and 23, 24

     
    • Continuous thermal current Ith

    6 A

    • Rated operational current Ie at rated operational voltage Ue
     
    • AC-15 at 230 V

    6 A

    • DC-13 at 24 V

    6 A

    • DC-13 at 115 V

    0.2 A

    • DC-13 at 230 V

    0.1 A

    Short-circuit protection
    for enabling circuits

     

    DIAZED fuse links

     
    • Operational class gG

    6 A

    • quick

    10 A

    Degree of protection according to IEC 60529

    IP20

    Ambient temperature

     
    • Operation

    –25 ... +45 °C

    • Storage, transport

    –25 ... +70 °C

    Connection

    Screw-type terminals