Товаров
  
корзина пуста

RFID standard cables

  • Заказные данные
    (24)
  • Аксессуары
    (3)
  • Информационные материалы

    Информационные материалы

    RFID standard cable that is used with SIMATIC RFID systems preassembled in various lengths.

    Область применения

    In addition to the normal areas of application in industry, the cable can also be laid:

    • In areas subject to high heat
    • For highly flexible applications (e.g. in cable carriers)
    • In oil-contaminated industrial environments
    • In outdoor applications exposed to solar radiation (UV radiation)

    Особенности

    Due to the cETLus certification with CMG test and marking, the cable can also be installed in fire protection critical building parts (e.g. vertical installation in a cable duct).

    The SIMATIC RFID standard cable can also be used in dynamic applications such as tow chains with a minimum bending radius of 75 mm.

    Технические данные

    Product type designation

    SIMATIC RFID standard cable

    Product description

    Highly flexible communication line (6-wire)

    Also suitable for use

    in continuous motion applications, such as with drag chains

    Cable designation

    L-YC11Y 6x1x0.25 6x24AWG CMG

    Electrical data

     

    Loop resistance per length/maximum

    160 Ω/km

    Mechanical data

     

    Number of electrical wires

    6

    Type of screen

    Tin-plated braided shield made of copper wires with 0.13 mm diameter (36 AWG)

    Wire diameter of the AWG24 wire

    0.70 mm

    Outer diameter

     
    • of the inner conductor

    0.70 mm

    • of the wire insulation

    1.2 mm

    • of the cable sheath

    5.4 mm

    Symmetrical tolerance of the outer diameter/of the cable sheath

    0.2 mm

    Material

     
    • of the wire insulation

    PVC

    • of the cable sheath

    PUR

    Color

     
    • of the data wire insulation

    white / yellow / gray / pink / brown / green

    • of the cable sheath

    Black

    Bending radius

     
    • for one-off bending / minimum permissible

    21.6 mm

    • for repeated bending / minimum permissible

    43 mm

    • with continuous bending

    75 mm

    Number of bending cycles

    3 million

    Number of bending cycles / note

    Suitable as trailing cable for 3 million bending cycles with a bending radius of 75 mm

    Tensile load / maximum

    200 N

    Permitted ambient conditions

     

    Ambient temperature

     
    • during operation

    -30 °C … 80 °C

    • during storage

    -30 °C … 80 °C

    • during transport

    -30 °C … 80 °C

    • during installation

    -30 °C … 80 °C

    Ambient temperature / comment

    Electrical properties measured at 20 °C

    Behavior in fire

    Flame-retardant acc. to IEC 60332-1-2

    Resistance

     
    • to mineral oil

    resistant

    • to grease

    resistant

    • Radiological resistance / to UV radiation

    resistant

    Product properties, functions, components / general

     
    • Halogen-free

    No

    • Silicon-free

    Yes

    Standards, specifications, approvals

     
    • UL listing / at 300 V rating

    Yes: CMG

    • UL listing / at 600 V rating

    No