Товаров
  
корзина пуста
  • Каталог оборудования Siemens

STEP 7 Professional V14 (TIA Portal)

  • Заказные данные
    (6)
  • Информационные материалы

    Информационные материалы

    STEP 7 Professional V14 (TIA Portal), portal view

    STEP 7 Professional V14 (TIA Portal), device view: configuring and parameterizing in realistic photo-quality representation

    Intuitive, efficient and future-oriented - the engineering software for programming the SIMATIC controllers

    SIMATIC STEP 7 Professional V14 is the engineering system for the SIMATIC S7-1200, S7-1500, S7-300, S7-400 controllers, WinAC and software controllers.

    STEP 7 V14 is based on the Totally Integrated Automation Portal (TIA Portal) central engineering framework, which offers users a uniform, efficient and intuitive solution for all automation tasks.

    New with V14
    • Supports new S7-1500T family, CPU 1518(F)-4 PN/DP ODK, CPU 1516pro (F)-2 PN and S7-1500 fail-safe software controllers
    • Useful function extensions in the language editors for LAD/FBD, S7-Graph and SCL
    • Systematic further development of language elements for programming (Array[*], Array of multi-instances, etc.)
    • Preconfigured and integrated connection and configuring of the SINAMICS V90 PN drive to a SIMATIC S7-1500 motion control technology object
    • Higher-level measurement with Trace
    • New configuring of toolbar in the DB Editor
    • New system functions, e.g. global search and extended cross-reference information
    • Multiple usability expansions for efficient engineering

    Область применения

    SIMATIC STEP 7 Professional V14 is the easy-to-use, integrated engineering system for the current SIMATIC S7-1200, S7-1500, S7-300 and S7-400 Controllers, WinAC, software controllers, and ET 200 CPU. PLCSIM for simulation of S7-1200/1500 CPU and WinCC Basic for configuration of Basic Panels are included in the scope of delivery.

    STEP 7 V14 thus provides support in all phases of the automation project:

    • Configuring and parameterizing the hardware
    • Specifying the communication
    • Programming in IEC programming editors
    • Configuring the visualization
    • Test, commissioning and service

    Функции

    Excellent integration of the SIMATIC S7-1500 controller

    With its multifaceted innovations, the SIMATIC S7-1500 controller from the SIMATIC S7 controller family sets new standards for maximum productivity. The SIMATIC S7-1500 is perfectly integrated into SIMATIC STEP 7 Professional V14 for maximum engineering efficiency. With its unique system performance and PROFINET as the standard interface, the SIMATIC S7-1500 is the new benchmark for performance.

    Powerful programming editors for efficient engineering

    STEP 7 Professional V14 provides powerful programming editors with optimized compilers for programming the S7 controllers.

    For all controllers:

    • Ladder diagram (LAD)
    • Function block diagram (FBD)
    • Structured text (SCL)

    Additionally for SIMATIC S7-1500, S7-300, S7-400, WinAC and software controllers:

    • Statement list (STL)
    • GRAPH for sequencers
    Tags trace for effective commissioning

    The Trace Editor provides the ability to record signals in chronological order from the user program of an S7-1500 CPU. The graphical evaluation of the signals simplifies, for example, the commissioning of drives and helps search for sporadic errors in the application or user program.

    Scalable and flexible motion functionality

    Motion control applications with SIMATIC STEP 7 Professional V14 and S7-1500 become child's play, even for beginners. The intuitive graphical user interfaces of the technology objects in STEP 7 Professional V14 provide optimal support for the configuring and commissioning of analog and PROFIdrive-capable drives, as well as for troubleshooting. The instructions for controlling the motion sequence are standardized according to PLCopen Motion Control. The following functions are supported in STEP 7 Professional V14:

    • Positioning (absolute and relative)
    • Speed specification (e.g. jogging)
    • Homing (active, on-the-fly, etc.)
    • Support of incremental and absolute encoders
    Comprehensive library concept

    The system has a comprehensive library concept for the reuse and simple standardization of frequently used program sections.

    Elements such as blocks, tags, alarms, HMI graphics, graphic objects, individual modules or entire stations can be stored along with their parameter assignment in local or global libraries. This means they are available for further programming tasks.

    Security Integrated

    STEP 7 Professional V14 has password-based know-how protection against unauthorized reading and changing of program block content.

    Copy protection offers greater protection against unauthorized copying of program blocks. These can be tied to the serial number of a memory card so that the block can only run if the configured memory card is inserted into the CPU.

    In addition, multiple user groups with different access rights can be assigned to the controller by means of four different authorization levels.

    Improved manipulation protection offers a greater degree of security against unauthorized changes to the data transferred between STEP 7 and the controller.

    Migration support for existing hardware and software products

    A migration tool integrated in SIMATIC STEP 7 Professional V14 provides support in switching from the S7-300/S7-400 to the S7-1500 controller and converts the program code automatically. Program code that cannot be converted automatically is logged and can be adapted manually. STEP 7 V12 SP1 projects can continue to be used with STEP 7 Professional V14 in compatibility mode.

    Team engineering - simultaneous processing of a task by more than one person

    Several individuals frequently work on the same project simultaneously, particularly during the engineering phase of an automation task. With TIA Portal V14 and the PLC proxy function it is possible to develop control and visualization tasks in parallel. Using a PLC proxy it is possible to import data to be visualized from a STEP 7 (TIA Portal) or STEP 7 V5.4 SP3 project into the WinCC V14 visualization project in order to implement the visualization there. Furthermore, STEP 7 Professional V14 and S7-1500 FW1.5 support online functions for commissioning which can be used by multiple users simultaneously.

    Особенности

    • Powerful programming editors for efficient engineering
    • Scalability across all series of controllers
    • Optimum interaction between the controller, HMI and drive in a working environment
    • Shared data management and uniform symbols
    • System diagnostics as an integral component
    • Variables trace for effective commissioning
    • Scalable and flexible motion control functionality
    • Comprehensive library concept
    • Security Integrated
    • Migration support for existing hardware and software products

    Технические данные

     

    STEP 7 Professional V14 (TIA Portal)

    Type of license

    Floating license

    Software class

    A

    Current version

    V14

    Target system

    SIMATIC S7-1200, S7-1500, S7-300, S7-400, WinAC, software controllers

    Minimum software and hardware requirements

     

    Processor

    Intel Core i3-6100M 2.30 GHz or higher

    RAM

    4 GB

    Hard disk

    SATA with at least 8 GB storage space

    Network

    100 Mbit or more

    Screen resolution

    1024 x 768

    Operating systems

    Windows 7 (64-bit)

    • Windows 7 Professional SP1
    • Windows 7 Enterprise SP1
    • Windows 7 Ultimate SP1

    Windows 8.1 (64-bit)

    • Windows 8.1 Professional
    • Windows 8.1 Enterprise

    Windows Server (64-bit)

    • Windows Server 2008 R2 StdE SP1 (full installation)
    • Windows Server 2012 R2 StdE (full installation)

    Recommended PC hardware

     

    Computer

    SIMATIC Field PG M5 Advanced or higher (or comparable PC)

    Processor

    Intel Core i5-6440EQ (up to 3.4 GHz)

    RAM

    16 GB or more (32 GB for large projects)

    Hard disk

    SSD with at least 50 GB storage space available

    Network

    1 Gbit (for multi-user)

    Screen

    15.6" full HD display (1920 x 1080 or higher)



    Compatibility with other SIMATIC products

    STEP 7 Professional V14 (incl. WinCC Basic V14) can be installed on a PC in parallel with other versions of STEP 7 V12, V5.4 or V5.5, STEP 7 Micro/WIN, WinCC flexible (from 2008), S7-PCT (from V3.3) and WinCC (from V7.0 SP2).

    Дальнейшая информация

    TIA Portal highlights

    http://www.siemens.com/tiaportal

    Software download

    For up-to-date information and download availability, see:

    http://www.siemens.com/tia-online-software-delivery