Товаров
  
корзина пуста
  • Каталог оборудования Siemens

CP 1243-8 IRC

  • Заказные данные
    (1)
  • Аксессуары
    (6)
  • Информационные материалы

    Информационные материалы

    The CP 1243-8 IRC communication processor (Industrial Remote Communication) is used for connecting a SIMATIC S7-1200 in the TeleControl Professional system via the SINAUT ST7 telecontrol protocol to higher-level ST7 stations or to an ST7 control center.

    The CP has the following features:

    • SINAUT ST7 telecontrol protocol supported
    • Two WAN connections for selecting the communication paths:
      • Ethernet-based connection: RJ45 port on the module for connecting external routers, e.g. SCALANCE M
      • Additional connection configurable via plug-in TS modules
    • Both WAN interfaces can also be operated simultaneously: Route redundancy
    • Data transfer optimized for telecontrol systems on the basis of SINAUT ST7
    • Automatic transmission of alarms per e-mail or SMS
    • Time synchronization based on NTP (Network Time Protocol) or via the SINAUT system
    • Data buffering of up to 16,000 data messages prevents data loss in the event of temporary connection failures
    • Secure communication via VPN connections based on IPSec
    • Access protection via Stateful Inspection Firewall
    • Fast and simple diagnostics via clear LED indicators, STEP 7 and web browser
    • Compact industrial enclosure in S7-1200 design for mounting on a standard mounting rail

    The integrated Ethernet interface and the option of using the TS modules provide flexible connection options for the CP. The following TS modules are available:

    • TS module RS232
    • TS module MODEM
    • TS module ISDN and
    • TS module GSM.

    Область применения

    By using the new CP 1243-8 IRC, the SIMATIC S7-1200 can be used as a remote terminal unit (substation) in ST7 telecontrol applications. Typical applications are found in the areas of water/wastewater, oil and gas, and also in other areas of telecontrol technology such as railway control systems, wind farms, and traffic control systems. The CP 1243-8 IRC can be integrated into existing ST7 systems here, as well as being used in new systems with ST7.

    Typical fields of application are:

    • Safe supply of drinking water, gas, district heating, or electricity for private and industrial consumers via branched networks
    • Economical transportation of gas, oil or oil products through pipelines
    • Remote monitoring of unit-type district heating power plants, wind farms, and solar power plants
    • Monitoring and control of wastewater systems such as sewerage systems, storm-water overflow tanks, and treatment plants
    • Flood water protection and level monitoring
    • Control of traffic systems and telecommunication systems
    • Remote monitoring of levels in tanks and silos
    • Control of irrigation systems in agriculture or hothouses

    Дизайн

    The CP 1243-8 IRC offers all the advantages of the S7-1200 design:

    • Rugged, compact plastic enclosure
    • Easily accessible connection and diagnostics elements, protected by front flaps
    • Removable terminals
    • Simple mounting on the mounting rail of the S7-1200
    • 3-pin plug-in terminal strip for connection of the 24 V DC external supply voltage
    • Permissible slots:
      + A single CP 1243-8 IRC can be plugged in to the left of the S7-1200-CPU
      + A single TS module can be plugged in to the left of the CP 1243-8 IRC

    If a TS module is plugged in, the power is supplied via a 3-pin terminal strip on top of the module. Any required modems or routers are connected via the Ethernet interface on the underside of the module.

    Функции

    The CP 1243-8 IRC is a communication module for the SIMATIC S7-1200. The module makes it possible to connect the S7-1200 as an external station to the higher-level station (node and master) or to a control system via the SINAUT ST7 telecontrol protocol.

    Configuration

    The hardware and data are configured in STEP 7 V13 SP1 plus HSP011 (TIA Portal), and the ST7 connection is configured with STEP7 V5.5 plus SINAUT Engineering Software V5.5. The introduction of the "data point configuration" in STEP 7 dispenses with the programming effort for transfer of data to the control center. The data of the CPU relevant to the control center is selected via user-friendly "item browsing" in STEP 7. In a clearly-arranged menu, the data transfer parameters are then assigned to the data points selected in this way. The cyclic or event-controller transfer of measurements, setpoints or alarms can thus be implemented in only a few operations and without programming effort.

    Web server access

    Access to the Web server of the CPU via the Ethernet interface of the CP for easy diagnostics.

    Security

    Virtual Private Network (IPSec)
    The connection of S7-1200 via a VPN network ensures that only authenticated network stations can communicate with the controller. Secure encryption of the data and verification of the data integrity protects the data traffic from espionage and manipulation.

    Stateful Inspection Firewall

    By using a firewall, the S7-1200 can provide additional protection against unauthorized access and manipulation attempts. The firewall filters data packets and checks the communication connections in accordance with the filter list. Both incoming and outgoing communication is filtered on the basis of IP and MAC addresses.

    Alerting per e-mail or SMS

    Alarm e-mails and alarm SMS messages can be configured to provide the service and maintenance personnel promptly with the station states. If previously defined events (such as threshold violation) should occur, application-specific information is sent automatically by e-mail and SMS.

    Data backup

    Data losses are prevented by the data buffering mechanisms integrated in the device. In the event of a connection failure, up to 16,000 time-stamped data messages are buffered. When the connection returns, the buffered values are automatically transferred to the control center in the right order.

    Diagnostics

    The CP 1243-8 IRC offers comprehensive diagnostic options for a quick and informative analysis of the station status. Elementary diagnostic information about the connection to the control center is signaled directly via LEDs at the CP. Further extensive information can be called up via STEP 7 and the web server.

    Remote maintenance

    For remote access from the control center to the substation, the CP provides a remote maintenance port in parallel with process operation. This ensures access for monitoring and program changes.

    Особенности

    • Use of the SIMATIC S7-1200 as a low-cost, modular RTU with SINAUT ST7 telecontrol protocol in new systems
    • Investment protection through use in existing ST7 systems
    • Flexible options for connecting to IP-based networks or classic WAN networks
    • Selection of the WAN network type via TS modules that are plugged in to the left of the CP
    • High availability of the connections due to possible redundant design of the communication paths (parallel operation of Ethernet and the second WAN interface via TS modules)
    • Fully automatic time stamp: To enable subsequent and correct archiving of process data in the control system, all data frames are assigned a time stamp at their place of origin.
    • Alarms: Operating personnel informed immediately of alarms, statuses and values from the process via e-mail or SMS.
    • Simple and economical engineering: Cyclic or event-controlled transfer of measurements, setpoints or alarms can thus be implemented in only a few operations and without programming effort.
    • Remote diagnostics: Saving of traveling and maintenance costs due to economical remote maintenance, diagnostics, control and monitoring via the Internet
    • Industrial Security: Protection against data manipulation and third-party access through IT security functions such as firewall (Stateful Inspection) and secure connections (VPN with IPSec).

    Технические данные

    Order number

    6GK7243-8RX30-0XE0

    Product type designation

    CP 1243-8 IRC

    Transmission rate

     

    Transfer rate

     

    • at the 1st interface

    10 ... 100 Mbit/s

    • at the 2nd interface

    0.3 ... 115.2 kbit/s

    Interfaces

     

    Number of interfaces acc. to Industrial Ethernet

    1

    Number of electrical connections

     

    • at the 1st interface acc. to Industrial Ethernet

    1

    • for power supply

    1

    Type of electrical connection

     

    • at the 1st interface acc. to Industrial Ethernet

    RJ45 port

    • at interface 2 for external data transmission

    Interface to the TS Module

    • for power supply

    3-pole terminal block

    Supply voltage, current consumption, power loss

     

    Type of voltage of the supply voltage

    DC

    Supply voltage 1 from backplane bus

    5 V

    Supply voltage external

    24 V

    Supply voltage external

    19.2 ... 28.8 V

    Supply voltage external at DC Rated value

    24 V

    Supply voltage external at DC rated value

    19.2 ... 28.8 V

    Consumed current

     

    • from backplane bus at DC at 5 V typical

    0.25 A

    • from external supply voltage at DC at 24 V typical

    0.1 A

    Power loss [W] Note

    1.25 W from S7-1200 backplane without TS module. 2.4 W from 24 V DC external with TS module

    Power loss [W]

    2.4 W

    Permitted ambient conditions

     

    Ambient temperature

     

    • for vertical installation during operation

    -20 ... +60 °C

    • for horizontally arranged busbars during operation

    -20 ... +70 °C

    • during storage

    -40 ... -70 °C

    • during transport

    -40 ... +70 °C

    Relative humidity at 25 °C without condensation during operation maximum

    95 %

    Protection class IP

    IP20

    Design, dimensions and weight

     

    Module format

    Compact module S7-1200 single width

    Width

    30 mm

    Height

    110 mm

    Depth

    75 mm

    Net weight

    0.122 kg

    Mounting type

     

    • 35 mm DIN rail mounting

    Yes

    • S7-300 rail mounting

    No

    • wall mounting

    Yes

    Product properties, functions, components general

     

    Number of units

     

    • per CPU maximum

    1

    • Note

    One CP pluggable on left side of CPU, one TS Module pluggable left side of CP.

    Performance data open communication

     

    Number of possible connections for open communication

     

    • by means of T blocks maximum

    like CPU

    Performance data S7 communication

     

    Number of possible connections for S7 communication

     

    • with PG connections maximum

    2

    • with OP connections maximum

    1

    • Note

    Configured S7-Connection for ST7-Communication

    Service

     

    • SINAUT ST7 via S7 communication

    Yes

    Performance data IT functions

     

    Number of possible connections

     

    • as e-mail client maximum

    1

    Performance data telecontrol

     

    Suitability for use

     

    • Node station

    No

    • substation

    Yes

    • TIM control center

    No

    • Note

    Ethernet and TS Module can be operated in parallel

    Control center connection

    control center with ST7 function

    • by means of a permanent connection

    supported

    Protocol is supported

     

    • SINAUT ST7 protocol

    Yes

    Product function data buffering if connection is aborted

    Yes; 16,000 data messages

    Number of data points per station maximum

    200

    Transmission format

     

    • for SINAUT ST7 protocol with multi-master polling 10-bit

    Yes

    • for SINAUT ST7 protocol with polling or spontaneous 10-bit or 11-bit

    Yes

    Operating mode for scanning of data transmission

     

    • with dedicated line/radio link with SINAUT ST7 protocol

    Polling

    • with dial-up network with SINAUT ST7 protocol

    spontaneous

    Hamming distance

     

    • for SINAUT ST7 protocol

    4

    Performance data Teleservice

     

    Diagnostics function online diagnostics with SIMATIC STEP 7

    Yes

    Product function

     

    • program download with SIMATIC STEP 7

    Yes

    • Remote firmware update

    Yes

    Protocol is supported

     

    • SNMP v3

    Yes

    • DCP

    Yes

    Configuration software

     

    • required

    SINAUT ES V5.5 and STEP7 V13 SP1 or higher

    • for PG configuring required SINAUT ST7 configuration software for PG

    Yes

    Product functions Diagnosis

     

    Product function Web-based diagnostics

    Yes

    Product functions Security

     

    Firewall version

    stateful inspection

    Suitability for operation Virtual Private Network

    Yes

    Product function with VPN connection

    IPSec

    Type of encryption algorithms with VPN connection

    AES-256, AES-192, AES-128, 3DES-168, DES-56

    Type of authentication procedure with VPN connection

    Preshared key (PSK), X.509v3 certificates

    Type of hashing algorithms with VPN connection

    MD5, SHA-1

    Number of possible connections with VPN connection

    8

    Product function

     

    • password protection for teleservice access

    No

    • encrypted data transmission

    Yes

    • MSC client via GPRS modem with MSC capability

    Yes

    Protocol

     

    • is supported MSC protocol

    Yes

    • with Virtual Private Network MSC is supported

    TCP/IP

    Key length for MSC with Virtual Private Network

    128 bit

    Number of possible connections

     

    • as MSC client with VPN connection

    1

    • as MSC server with VPN connection

    0

    Product functions Time

     

    Protocol is supported

     

    • NTP

    Yes

    time synchronization

     

    • from NTP-server

    Yes

    • from control center

    Yes

    Accessories

     

    accessories

    TS Module RS232 or TS Module MODEM or TS Module ISDN or TS Module GSM pluggable


    Дальнейшая информация

    Technical requirements/compatibility

    CPU:

    An S7-1200 CPU with firmware version V4.1 or higher is required for operation.

    Configuring:

    Two engineering tools are required for configuring the CP 1243-8 IRC:

    • STEP7 V13 SP1 HSP011 must be used for configuring the hardware of the CP 1243-8 IRC.
    • STEP 7 V5.5 plus SINAUT Engineering Software V5.5 is used to configure the connection-specific SINAUT parameters (ST7 connection configuration).

    These connection parameters are made available to the TIA Portal in the form of SDBs using a transfer file created by the SINAUT Engineering Software.

    Control center:

    The respective SINAUT ST7cc or PCS7 TeleControl control center software is required for connecting the control center with WinCC or PCS 7. SINAUT ST7sc is available for connecting to third-party systems.