SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm

  • Заказные данные
    (50)
  • Аксессуары
    (7)
  • Информационные материалы

    Информационные материалы

    SIRIUS 3RP25 timing relays

    Further information

    Home page, see http://www.siemens.com/relays

     

    Industry Mall, see http://www.siemens.com/product?3RP25

     

    For the conversion tool, e.g. from 3RP15 to 3RP25, see http://www.siemens.com/sirius/conversion-tool

     



    Electronic timing relays for general use in control systems and mechanical engineering with:

    • 1 or 2 CO contacts, 1 NO contact (semiconductor) or 3 NO contacts
    • Monofunction or multifunction
    • Combination voltage or wide voltage range
    • Single or selectable time setting ranges
    • Switch position indication and voltage indication by LED
    Article No. scheme

    Product versions

    Article number

     

    Timing relays

    3RP25

    -

    0

     

    Product function/
    time setting ranges

    Multifunction

     

    0

    5

          

    7 time ranges 0.05 s ... 100 h

    ON-delay

     

    1

    1

          

    1 time range 0.05 ... 10 s

     

    1

    2

          

    1 time range 1 ... 3 s

     

    1

    3

          

    1 time range 5 ... 100 s

     

    2

    5

          

    7 time ranges 0.05 s ... 100 h

     

    2

    7

          

    4 time ranges 0.05 s ... 240 s

    OFF-delay with control signal

     

    3

    5

          

    7 time ranges 0.05 s ... 100 h

    OFF-delay without control signal, non-volatile, passing make contact

     

    4

    0

          

    7 time ranges 0.05 s ... 600 s

    Clock-pulse relay, flashing, asymmetrical

     

    5

    5

          

    7 time ranges 0.05 s ... 100 h

    Wye-delta function with overtravel function (idling)

     

    6

    0

          

    Wye-delta 1 ... 20 s, coasting time (idling) 600 s

    Wye-delta function

     

    7

    4

          

    1 time range 1 ... 20 s

      

    7

    6

          

    1 time range 3 ... 60 s

    Connection type

    Screw terminals

        

    1

         

    Spring-type terminals (push-in)

        

    2

         

    Contacts

    1 CO

         

    A

        

    2 CO

         

    B

        

    Semiconductors (transistor NPN)

         

    C

        

    Semiconductors (thyristor), two-wire

         

    E

        

    1 NO + 1 NO (SD)

         

    N

        

    2 CO positively driven

         

    R

        

    3 NO

         

    S

        

    Control supply voltage

    24 V AC/DC

          

    B

    3

      

    200 … 240 V/380 … 440 V AC

          

    M

    2

      

    400 ... 440 V AC

          

    T

    2

      

    12 ... 240 V AC/DC or 24 ... 240 V°AC/DC (3RP2505‑.RW30)

          

    W

    3

      

    Example

    3RP25

    0

    5

    -

    1

    A

    B

    3

    0

     


    Note:

    The Article No. scheme shows an overview of product versions for better understanding of the logic behind the article numbers. For your orders please use the article numbers quoted in the selection and ordering data.

    3RP2505 multifunctional timing relay

    Setting the functions on the device

    The functions of the 3RP2505 multifunctional timing relay can be set by means of the function selector switch. Whether both CO contacts are switched in parallel or one CO contact with a delay and one instantaneously and the choice of time setting range are set by means of the time setting range selector switch. The precise operating time can be set using the operating time switch.

    The timing relay can be clearly labeled with the selectable functions using a set of labels. This is included in the scope of supply of the multifunctional relay.

    The same potential must be applied to terminals A. and B.

    Note:

    The activation of loads parallel to the start input is permissible when using AC control voltage (see circuit diagram).

    Circuit diagram

    Overview of functions

    Identification letter

    13 functions

    1 CO contact (1 CO), 1 NO contact (1 NO) semiconductor,
    2 CO contacts switched in parallel (2 CO) or
    2 CO contacts positively driven and switched in parallel with delay (2 CO)

    27 functions

    13 functions (A - M) 2 CO contacts switching in parallel (2 CO) + 13 functions (A - M) 1 CO delayed contact + 1 CO instantaneous contact (1 CO + 1 CO) and wye-delta function

    A

    ON-delay

    ON-delay and instantaneous contact

    B

    OFF-delay with control signal

    OFF-delay with control signal and instantaneous contact

    C

    ON-delay / OFF-delay with control signal

    ON-delay / OFF-delay with control signal and instantaneous contact

    D

    Flashing, symmetrical, starting with interval

    Flashing, symmetrical, starting with interval and instantaneous contact

    E

    Passing make contact, interval relay

    Passing make contact, interval relay and instantaneous contact

    F

    Retriggerable interval relay with deactivated control signal (passing break contact with control signal)

    Retriggerable interval relay with deactivated control signal (passing break contact with control signal) and instantaneous contact

    G

    Passing make contact with control signal, not retriggerable, (pulse-forming with control signal)

    Passing make contact with control signal, not retriggerable, (pulse-forming with control signal) and instantaneous contact

    H

    Additive ON-delay, instantaneous OFF with control signal

    Additive ON-delay, instantaneous OFF with control signal and instantaneous contact

    I

    Additive ON-delay with control signal

    Additive ON-delay with control signal and instantaneous contact

    J

    Flashing, symmetrical, starting with pulse

    Flashing, symmetrical, starting with pulse and instantaneous contact

    K

    Pulse-delayed (fixed pulse (at 1 s) and settable pulse delay)

    Pulse-delayed (fixed pulse (at 1 s) and settable pulse delay) and instantaneous contact

    L

    Pulse-delayed with control signal (fixed pulse (at 1 s) and settable pulse delay)

    Pulse-delayed with control signal (fixed pulse (at 1 s) and settable pulse delay) and instantaneous contact

    M

    Retriggerable interval relay with activated control signal (watchdog)

    Retriggerable interval relay with activated control signal and instantaneous contact (watchdog)

    --

    --

    Wye-delta function



    Область применения

    Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings.

    Enclosure version

    All timing relays are suitable for snap-on mounting onto TH 35 standard mounting rails according to IEC 60715 or for screw fixing.

    Особенности

    • Simple inventory management and logistics thanks to low device variance
    • Less space required in the control cabinet thanks to 17.5 mm und 22 mm wide versions
    • Consistent in all functions due to wide voltage range from 12 to 240 V AC/DC
    • Up to 27 functions according to IEC 61812 in the multifunctional timing relay with wide voltage range
    • Multifunctional timing relay with semiconductor output for high switching frequencies, bounce-free and wear-free switching

    Standards and approvals

    • IEC 60721-3-3 "Classification of environmental conditions"
    • IEC 61812-1/DIN VDE 0435 Part 2021 "Specified time relays for industrial use"
    • IEC 61000-6-2, IEC 61000-6-3 and IEC 61000-6-4 "Electromagnetic compatibility"
    • IEC 60947-5-1 "Low-voltage switchgear and controlgear – Electromechanical control circuit devices"

    Технические данные

    Order number

     

    3RP2505-.A
    3RP2505-.C
    3RP251.
    3RP2525-.A
    3RP2527
    3RP253.
    3RP255.

    3RP2505-.B
    3RP2505-.R
    3RP2525-.B
    3RP254.
    3RP256.
    3RP257.

    Width x Height x Depth

    mm

    17.5 × 100 × 90

    22.5 × 100 × 90


    Order number

     

    3RP25..-.AB30
    3RP25..-.AW30
    3RP25..-.BB30
    3RP25..-.BW30
    3RP25..-.NW30
    3RP25..-.SW30

    3RP25..-.BT20
    3RP25..-.NM20

    3RP25..-.CW30

    3RP25..-.EW30

    3RP25..-.RW30

    General technical data:

     

     

     

     

     

     

    Insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value

    V

    300

    500

    300

    --

    300

    Ambient temperature

     

     

     

     

     

     

    • during operation

    °C

    -25 ... +60

    -40 ... +70

    • during storage

    °C

    -40 ... +85

    Operating range factor control supply voltage rated value

     

     

     

     

     

     

    • at AC

     

     

     

     

     

     

    • at 50 Hz

     

    0.85 ... 1.1

    0.7 ... 1.1

    • at 60 Hz

     

    0.85 ... 1.1

    0.7 ... 1.1

    • at DC

     

    0.85 ... 1.1

    --

    0.85 ... 1.1

    0.7 ... 1.1

    Switching capacity current with inductive load

    A

    0.01 ... 3

    0.01 ... 1

    0.01 ... 0.6

    0.01 ... 3

    Operating current of auxiliary contacts

     

     

     

     

     

     

    • at AC-15

     

     

     

     

     

     

    • at 24 V

    A

    3

    1

    --

    3

    • at 250 V

    A

    3

    1

    --

    3

    • at 400 V

    A

    --

    3

    --

    • at DC-12

     

     

     

     

     

     

    • at 24 V

    A

    --

    1

    --

    • at 125 V

    A

    --

    1

    --

    • at 250 V

    A

    --

    1

    --

    • at DC-13

     

     

     

     

     

     

    • at 24 V

    A

    1

    --

    1

    • at 125 V

    A

    0.2

    --

    0.2

    • at 250 V

    A

    0.1

    --

    0.1

    Thermal current

    A

    5

    1

    0.6

    5

    Mechanical service life (switching cycles) typical

     

    10 000 000

    Electrical endurance (switching cycles) at AC-15 at 230 V typical

     

    100 000

    300 000

    100 000


    Order number

     

    3RP25 ..-1...0

    3RP25 ..-2...0

    Type of electrical connection for auxiliary and control current circuit

     

    screw-type terminals

    PUSH-IN connection (spring-loaded connection)

    Design of the thread of the connection screw

     

    M3

    --

    Tightening torque

    N·m

    0.6 ... 0.8

    --

    Type of connectable conductor cross-sections

     

     

     

    • solid

     

    1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)

    0.5 ... 4 mm²

    • finely stranded with core end processing

     

    1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)

    0.5 ... 2.5 mm²

    • at AWG conductors

     

     

     

    • solid

     

    1x (20 ... 12), 2x (20 ... 14)

    20 ... 12

    • stranded

     

    1x (20 ... 12), 2x (20 ... 14)

    20 ... 12


    Дополнительно

    Further information

    For information on configuring and dimensioning the accessories in the manual, see https://support.industry.siemens.com/cs/ww/en/view/103532830