Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS ET 200MP IM 155-5 PN ST TX RAIL

  • Заказные данные
    (1)
  • Информационные материалы

    Информационные материалы

    • Interface module for linking the ET 200MP to PROFINET
    • Approved in accordance with the railway standards EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 for use in rail traffic
    • Handles data exchange with the PROFINET I/O controller in the PLC
    • Integrated 2-port switch for line topology
    • Max. 30 I/O modules
    • Shortest bus cycle 250 µs
    • Linking to the isochronous task of the CPU
    • Prioritized fast startup (FSU) with 500 ms (max. 12 I/O modules)
    • Media Redundancy Protocol (MRP)
    • Shared device on up to 2 I/O controllers (when configuring using GSD file; depends on the respective configuration tool)
    • Omission of SIMATIC memory card (SMC); IM replacement without PG using LLDP

    Область применения

    The SIPLUS ET 200MP IM 155-5 PN ST TX RAIL interface module enables the connection of the ET 200MP to PROFINET and handles communication between the modules and the higher-level I/O controller autonomously.

    Дизайн

    The SIPLUS ET 200MP IM 155-5 PN ST TX RAIL interface module is screwed directly onto the S7-1500 rail. It incorporates:

    • Diagnostics displays for errors (Error), operation (RUN), maintenance (MAINT), and one link LED per port
    • Connection to PROFINET using RJ45 connector
    • 24 V DC supply unit for looping through the supply voltage
    • Protection of interface module against unauthorized access possible using lock, seal or cable tie

    Технические данные

    Order number

    6AG2155-5AA00-4AB0

    SIPLUS ET 200MP IM 155-5 PN ST TX RAIL

    General information

     

    Product type designation

    IM 155-5 PN ST

    Product function

     

    • I&M data

    Yes; I&M0 to I&M3

    Supply voltage

     

    Type of supply voltage

    DC

    Rated value (DC)

    24 V

    Reverse polarity protection

    Yes

    Short-circuit protection

    Yes

    Mains buffering

     

    • Mains/voltage failure stored energy time

    5 ms

    Hardware configuration

     

    Rack

     

    • Modules per rack, max.

    30; I/O modules

    Interfaces

     

    Number of PROFINET interfaces

    1

    1. Interface

     

    Interface types

     

    • Number of ports

    2

    • integrated switch

    Yes

    • RJ 45 (Ethernet)

    Yes

    Functionality

     

    • PROFINET IO Device

    Yes

    • Media redundancy

    Yes

    Interface types

     

    RJ 45 (Ethernet)

     

    • Transmission procedure

    PROFINET with 100 Mbit/s full duplex (100BASE-TX)

    • 100 Mbps

    Yes

    • Autonegotiation

    Yes

    • Autocrossing

    Yes

    PROFINET IO Device

     

    Services

     

    • Isochronous mode

    Yes

    • IRT

    Yes

    • MRP

    Yes

    • Prioritized startup

    Yes

    • Shared device

    Yes

    • Number of IO Controllers with shared device, max.

    2

    Open IE communication

     

    • TCP/IP

    Yes

    • SNMP

    Yes

    • LLDP

    Yes

    Isochronous mode

     

    Isochronous operation (application synchronized up to terminal)

    Yes

    Equidistance

    Yes

    shortest clock pulse

    250 µs

    max. cycle

    4 ms

    Interrupts/diagnostics/status information

     

    Status indicator

    Yes

    Alarms

    Yes

    Diagnostic functions

    Yes

    Diagnostics indication LED

     

    • RUN LED

    Yes; Green LED

    • ERROR LED

    Yes; Red LED

    • MAINT LED

    Yes; yellow LED

    • Connection display LINK TX/RX

    Yes; yellow LED

    Isolation

     

    Isolation tested with

    707 V DC (type test) and according to EN 50155 (routine test)

    Standards, approvals, certificates

     

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class Tx, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Ambient temperature during operation

     

    • horizontal installation, min.

    -40 °C; = Tmin

    • horizontal installation, max.

    70 °C; = Tmax; from > +60 °C no module permissible left of the IM; +85 °C for 10 min. (Tx acc. to EN 50155)

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Dimensions

     

    Width

    35 mm

    Height

    147 mm

    Depth

    129 mm

    Weights

     

    Weight, approx.

    310 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776