Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS extreme S7-1200 SM 1232 RAIL

  • Заказные данные
    (1)
  • Информационные материалы

    Информационные материалы

    • Analog outputs for SIPLUS S7-1200
    • Approved in accordance with the EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 railway standards for use in rail traffic
    • With extremely short conversion times
    • For connecting analog actuators without additional amplifiers
    • Even solves more complex automation tasks

    Область применения

    SM 1232 analog output signal modules permit the use of analog outputs.

    This provides users with the following advantages:

    • Optimal adaptation:
      With analog signal modules, users can optimally adapt their controllers even to more complex tasks.
    • Direct connection of actuators:
      up to 14 bit resolution permit the connection of actuators without an additional amplifier.
    • Flexibility:
      if the task is expanded subsequently, the controller can be upgraded. Updating of the user program is extremely simple.

    Дизайн

    The signal modules have the same design features as the basic devices.

    • Installation on DIN rails:
      The modules are snapped onto the rail next to the CPU on the right and are electrically and mechanically connected to each other and to the CPU by the integral slide mechanism.
    • Direct installation:
      Horizontal or vertical mounting on DIN rail or direct mounting in the cabinet using integral lugs.

    Функции

    SM 1232 analog output signal modules convert digital signals of the SIMATIC S7-1200 into signals for controlling the respective process.

    Технические данные

    Order number

    6AG2232-4HD32-1XB0

    SIPLUS S7-1200 SM 1232 4AQ RAIL

    General information

     

    Product type designation

    SM 1232 AQ 4 x 14bit

    Supply voltage

     

    Rated value (DC)

    • 24 V DC

    Yes

    Input current

     

    Current consumption, typ.

    45 mA

    from backplane bus 5 V DC, typ.

    80 mA

    Power loss

     

    Power loss, typ.

    1.5 W

    Analog outputs

     

    Number of analog outputs

    4; Current or voltage

    Output ranges, voltage

     

    • -10 V to +10 V

    Yes

    Output ranges, current

     

    • 0 to 20 mA

    Yes

    Load impedance (in rated range of output)

     

    • with voltage outputs, min.

    1 000 Ω

    • with current outputs, max.

    600 Ω

    Analog value generation for the outputs

     

    Integration and conversion time/resolution per channel

     

    • Resolution (incl. overrange)

    Voltage: 14 bits; Current : 13 bits

    Errors/accuracies

     

    Temperature error (relative to output range), (+/-)

    25 °C ±0.3%, to 55 °C ±0.6% total measurement range

    Basic error limit (operational limit at 25 °C)

     

    • Voltage, relative to output range, (+/-)

    0.3 %

    • Current, relative to output range, (+/-)

    0.3 %

    Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

     

    • Common mode voltage, max.

    12 V

    Interrupts/diagnostics/status information

     

    Alarms

    Yes

    Diagnostic functions

    Yes

    Alarms

     

    • Diagnostic alarm

    Yes

    Diagnostic messages

     

    • Monitoring the supply voltage

    Yes

    • Wire-break

    Yes

    • Short-circuit

    Yes

    Diagnostics indication LED

     

    • for status of the outputs

    Yes

    • for maintenance

    Yes

    Degree and class of protection

     

    Degree of protection acc. to EN 60529

    • IP20

    Yes

    Standards, approvals, certificates

     

    CE mark

    Yes

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Free fall

     

    • Fall height, max.

    0.3 m; five times, in product package

    Ambient temperature during operation

     

    • min.

    -25 °C

    • max.

    60 °C; = Tmax; +70 °C for 10 minutes (T1 acc. to EN 50155) for horizontal mounting position

    Ambient temperature during storage/transportation

     

    • min.

    -40 °C

    • max.

    70 °C

    Air pressure acc. to IEC 60068-2-13

     

    • Storage/transport, min.

    660 hPa

    • Storage/transport, max.

    1 080 hPa

    Relative humidity

     

    • permissible range (without condensation) at 25 °C

    95 %

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Connection method

     

    required front connector

    Yes

    Mechanics/material

     

    Enclosure material (front)

    • Plastic

    Yes

    Dimensions

     

    Width

    45 mm

    Height

    100 mm

    Depth

    75 mm

    Weights

     

    Weight, approx.

    180 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776