    The following table provides an overview of the available options. Detailed descriptions of the options are provided in the section "Description of the options".

    Order code

    Option

    A06

    Brush length monitoring, limit value monitoring, isolated

    A30

    Anti-condensation heating for motor, up to max. 2 000 W, 230 V

    A97

    Air flow monitoring in the motor

    B30

    Interlocking option for infeed circuit breaker

    B60

    Display instrument, "speed"

    B61

    Display instrument, "armature voltage"

    B62

    Display instrument, "armature current"

    B63

    Display instrument, "line voltage excitation"

    B64

    Display instrument, "excitation current"

    B65

    Display instrument, "line voltage armature circuit"

    B66

    Display instrument, "line current"

    B83

    Overvoltage protection

    C51

    24 V coil voltage of the coupling relay at the binary inputs

    D02

    Customer documentation (circuit diagram, terminal diagram, layout diagram) in the DXF format

    D04

    Customer documentation, paper

    D14

    Preliminary customer documentation

    D19

    Circuit diagram prepared for motor overtemperature monitoring using a limit value transmitter

    D20

    Circuit diagram prepared for motor temperature monitoring

    D21

    Circuit diagram prepared for speed actual value sensing (pulse encoder)

    D22

    Circuit diagram prepared for speed actual value sensing (analog tachometer)

    D58

    Documentation language: English/French

    D60

    Documentation language: English/Spanish

    D61

    Documentation language: English/Russian

    D80

    Documentation language: English/Italian

    F03

    Equipment acceptance with customer present: visual acceptance

    F97

    Equipment acceptance with customer present: customer-specific acceptance

    G00

    Advanced CUD left

    G10

    Standard CUD right

    G11

    Advanced CUD right

    G20

    Communication Board CBE20 left

    G21

    Communication Board CBE20 right

    G60

    Customer terminal strip extension TM31

    G62

    Customer terminal strip extension TM15

    K07

    Without Advanced Operator Panel AOP30

    K50

    Sensor Module Cabinet-Mounted SMC30

    K85

    Field reversal

    L00

    Radio interference suppression filter

    L04

    Armature supply with extra-low voltage 10 to 50 V

    L05

    Electronics power supply, SINAMICS DC MASTER for connection to 24 V DC

    L06

    24 V DC power supply with SITOP

    L07

    24 V DC power supply from an external supply

    L09

    24 V DC power supply with SITOP UPS

    L10

    Without field power section

    L11

    Field power section 2Q

    L21

    Unit fan for single-phase connection

    L22

    Elimination of the three-phase commutating reactor

    L50

    Cabinet lighting and service outlet

    L52

    ARC detector (arcing detector)

    L55

    Cabinet anti-condensation heating

    L57

    EMERGENCY OFF Category 0 for uncontrolled stopping in accordance with EN 60204-1

    L59

    EMERGENCY STOP Category 1 for controlled stopping in accordance with EN 60204-1

    L82

    Fault current monitoring in the grounded line supplies (TN or TT systems)

    L84

    PTC thermistor evaluation unit for alarm or fault for two sensors

    L85

    85 A field power section

    L86

    Evaluation unit for the following temperature sensors: KTY84-130, PT100 2-wire and 3-wire, PT1000 2-wire and 3-wire, NTC

    L87

    Insulation monitoring in non-grounded line supplies (IT system) with insulating monitoring devices from the Bender company

    L88

    Insulation monitoring in non-grounded line supplies (IT system) with insulating monitoring devices from the AREVA company

    L90

    CCP (Converter Commutation Protector)

    L91

    Commissioning interface (PROFIBUS) cabinet door access

    L99

    Monitoring the temperature inside the drive cabinet

    M06

    Base 100 mm high, RAL 7022

    M07

    Cable-marshaling space 200 mm high, RAL 7035

    M08

    Coated PCBs (only involves modules of the SINAMICS DC MASTER DC Converter)

    M10

    Nickel-plated copper busbars

    M21

    Degree of protection IP21

    M23

    Degree of protection IP23

    M43

    Degree of protection IP43

    M54

    Degree or protection IP54 with filter elements

    M58

    Degree or protection IP54 with climate control unit

    M59

    Cabinet door closed, entry from the bottom through an opening in the floor

    M60

    Additional shock hazard protection

    M66

    Marine version

    M90

    Crane transport aid (mounted at the top)

    M91

    Packaging type: wooden crate

    M92

    Packaging type: crate

    M93

    Packaging type: crate, seaworthy packaging

    M94

    Packaging type: additional packaging data IPPC ISPM15 (according to country-specific regulations)

    P11

    Display instrument for line quantities with PROFIBUS interface, installed in the cabinet door

    Q80 … Q85

    Extension of liability for defects – refer to the Section, “Description of the options”

    S01

    Memory card left

    S02

    Memory card right

    U09

    Version according to UL Listing

    V60

    Control extension for a rated line frequency of 60 Hz

    V70

    Input isolating amplifier, input: 0 to 20 mA

    V71

    Input isolating amplifier, input: 4 to 20 mA

    V72

    Input isolating amplifier, input: 0 to +10 V

    V73

    Input isolating amplifier, input: –20 to +20 mA

    V74

    Input isolating amplifier, input: –10 to +10 V

    W15

    No output provided for a motor fan

    W20 … W41

    Setting range of the motor protection circuit breaker for the motor fan

    W70 … W91

    Feeder for a second motor fan

    Y01

    Matching transformer for the motor fan

    Y02

    Matching transformer for the field supply

    Y03

    3 AC auxiliary voltage not available

    Y04

    3 AC auxiliary voltage not the same as the standard voltage

    Y09

    Special cabinet paint finish

    Y32

    Labeling plate to identify the system, two lines, 40 × 180 mm

    Y51

    Motor holding brake

    Y52

    Output isolating amplifier, output: 0 to 20 mA

    Y53

    Output isolating amplifier, output: 4 to 20 mA

    Y54

    Output isolating amplifier, output: 0 to 10 V

    Y55

    Output isolating amplifier, output: –20 to +20 mA

    Y56

    Output isolating amplifier, output: –10 to 10 V

    Y60

    Coupling relay for binary output

     

    Customer-specific requirement



    Options-selection matrices

    The following selection matrices include options, which mutually exclude one another. Only the options, where an exclusion is not obvious, are shown.

    Components

     

    G00

    G10

    G11

    G20

    G21

    L04

    L05

    L06

    L07

    L09

    L10

    L11

    L85

    L00

    L22

    Y02

    Advanced CUD left

    G00

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Standard CUD right

    G10

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Advanced CUD right

    G11

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Communication Board CBE20 left

    G20

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Communication Board CBE20 right

    G21

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Armature supply with extra-low voltage 10 to 50 V

    L04

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Electronics power supply, SINAMICS DC MASTER for connection to 24 V DC

    L05

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    24 V DC power supply with SITOP

    L06

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    24 V DC power supply from an external supply

    L07

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    24 V DC power supply with SITOP UPS

    L09

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    Without field power section

    L10

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    Field power section 2Q

    L11

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    85 A field power section

    L85

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    ✓ 

    ✓ 

    Radio interference suppression filter

    L00

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    Elimination of the three-phase commutating reactor

    L22

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     

    ✓ 

    Matching transformer for the field supply

    Y02

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

    ✓ 

     



    Legend

    ✓ 

    Options can be combined without any restrictions

    Options cannot be combined



    Degree of protection

     

    M21

    M23

    M43

    M54

    M58

    M59

    Degree of protection IP21

    M21

     

    ✓ 

    Degree of protection IP23

    M23

     

    ✓ 

    Degree of protection IP43

    M43

     

    Degree of protection IP54

    M54

     

    Degree or protection IP54 with filter elements

    M58

     

    Cabinet door closed, entry from the bottom through an opening in the floor

    M59

    ✓ 

    ✓ 

     



    Legend

    ✓ 

    Options can be combined without any restrictions

    Options cannot be combined



    Auxiliary voltage

     

    Y03

    Y04

    3 AC auxiliary voltage not available

    Y03

     

    3 AC auxiliary voltage not the same as the standard voltage

    Y04

     



    Legend

    Options cannot be combined