- Каталог оборудования Siemens
- Каталог продуктов Siemens Industry
- Приводная техника
- Преобразователи
- Двигатели переменного тока
- Generators
- Мотор-редукторы
- Flender Gear Units
- Couplings
- Инструментальное программное обеспечение
- Дополнительные компоненты
- Техника автоматизации
- Energy
- Автоматизация и безопасность зданий
- Низковольтная коммутационная техника
- Технология безопасности
- Системные решения и продукты для отраслей
- Сервис
- Приводная техника
- Информационные материалы
Информационные материалы
The following table provides an overview of the available options. Detailed descriptions of the options are provided in the section "Description of the options".
Order code
Option
A06
Brush length monitoring, limit value monitoring, isolated
A30
Anti-condensation heating for motor, up to max. 2 000 W, 230 V
A97
Air flow monitoring in the motor
B30
Interlocking option for infeed circuit breaker
B60
Display instrument, "speed"
B61
Display instrument, "armature voltage"
B62
Display instrument, "armature current"
B63
Display instrument, "line voltage excitation"
B64
Display instrument, "excitation current"
B65
Display instrument, "line voltage armature circuit"
B66
Display instrument, "line current"
B83
Overvoltage protection
C51
24 V coil voltage of the coupling relay at the binary inputs
D02
Customer documentation (circuit diagram, terminal diagram, layout diagram) in the DXF format
D04
Customer documentation, paper
D14
Preliminary customer documentation
D19
Circuit diagram prepared for motor overtemperature monitoring using a limit value transmitter
D20
Circuit diagram prepared for motor temperature monitoring
D21
Circuit diagram prepared for speed actual value sensing (pulse encoder)
D22
Circuit diagram prepared for speed actual value sensing (analog tachometer)
D58
Documentation language: English/French
D60
Documentation language: English/Spanish
D61
Documentation language: English/Russian
D80
Documentation language: English/Italian
F03
Equipment acceptance with customer present: visual acceptance
F97
Equipment acceptance with customer present: customer-specific acceptance
G00
Advanced CUD left
G10
Standard CUD right
G11
Advanced CUD right
G20
Communication Board CBE20 left
G21
Communication Board CBE20 right
G60
Customer terminal strip extension TM31
G62
Customer terminal strip extension TM15
K07
Without Advanced Operator Panel AOP30
K50
Sensor Module Cabinet-Mounted SMC30
K85
Field reversal
L00
Radio interference suppression filter
L04
Armature supply with extra-low voltage 10 to 50 V
L05
Electronics power supply, SINAMICS DC MASTER for connection to 24 V DC
L06
24 V DC power supply with SITOP
L07
24 V DC power supply from an external supply
L09
24 V DC power supply with SITOP UPS
L10
Without field power section
L11
Field power section 2Q
L21
Unit fan for single-phase connection
L22
Elimination of the three-phase commutating reactor
L50
Cabinet lighting and service outlet
L52
ARC detector (arcing detector)
L55
Cabinet anti-condensation heating
L57
EMERGENCY OFF Category 0 for uncontrolled stopping in accordance with EN 60204-1
L59
EMERGENCY STOP Category 1 for controlled stopping in accordance with EN 60204-1
L82
Fault current monitoring in the grounded line supplies (TN or TT systems)
L84
PTC thermistor evaluation unit for alarm or fault for two sensors
L85
85 A field power section
L86
Evaluation unit for the following temperature sensors: KTY84-130, PT100 2-wire and 3-wire, PT1000 2-wire and 3-wire, NTC
L87
Insulation monitoring in non-grounded line supplies (IT system) with insulating monitoring devices from the Bender company
L88
Insulation monitoring in non-grounded line supplies (IT system) with insulating monitoring devices from the AREVA company
L90
CCP (Converter Commutation Protector)
L91
Commissioning interface (PROFIBUS) cabinet door access
L99
Monitoring the temperature inside the drive cabinet
M06
Base 100 mm high, RAL 7022
M07
Cable-marshaling space 200 mm high, RAL 7035
M08
Coated PCBs (only involves modules of the SINAMICS DC MASTER DC Converter)
M10
Nickel-plated copper busbars
M21
Degree of protection IP21
M23
Degree of protection IP23
M43
Degree of protection IP43
M54
Degree or protection IP54 with filter elements
M58
Degree or protection IP54 with climate control unit
M59
Cabinet door closed, entry from the bottom through an opening in the floor
M60
Additional shock hazard protection
M66
Marine version
M90
Crane transport aid (mounted at the top)
M91
Packaging type: wooden crate
M92
Packaging type: crate
M93
Packaging type: crate, seaworthy packaging
M94
Packaging type: additional packaging data IPPC ISPM15 (according to country-specific regulations)
P11
Display instrument for line quantities with PROFIBUS interface, installed in the cabinet door
Q80 … Q85
Extension of liability for defects – refer to the Section, “Description of the options”
S01
Memory card left
S02
Memory card right
U09
Version according to UL Listing
V60
Control extension for a rated line frequency of 60 Hz
V70
Input isolating amplifier, input: 0 to 20 mA
V71
Input isolating amplifier, input: 4 to 20 mA
V72
Input isolating amplifier, input: 0 to +10 V
V73
Input isolating amplifier, input: –20 to +20 mA
V74
Input isolating amplifier, input: –10 to +10 V
W15
No output provided for a motor fan
W20 … W41
Setting range of the motor protection circuit breaker for the motor fan
W70 … W91
Feeder for a second motor fan
Y01
Matching transformer for the motor fan
Y02
Matching transformer for the field supply
Y03
3 AC auxiliary voltage not available
Y04
3 AC auxiliary voltage not the same as the standard voltage
Y09
Special cabinet paint finish
Y32
Labeling plate to identify the system, two lines, 40 × 180 mm
Y51
Motor holding brake
Y52
Output isolating amplifier, output: 0 to 20 mA
Y53
Output isolating amplifier, output: 4 to 20 mA
Y54
Output isolating amplifier, output: 0 to 10 V
Y55
Output isolating amplifier, output: –20 to +20 mA
Y56
Output isolating amplifier, output: –10 to 10 V
Y60
Coupling relay for binary output
Customer-specific requirement
Options-selection matrices
The following selection matrices include options, which mutually exclude one another. Only the options, where an exclusion is not obvious, are shown.
Components
G00
G10
G11
G20
G21
L04
L05
L06
L07
L09
L10
L11
L85
L00
L22
Y02
Advanced CUD left
G00
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Standard CUD right
G10
✓
–
✓
–
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Advanced CUD right
G11
✓
–
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Communication Board CBE20 left
G20
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Communication Board CBE20 right
G21
✓
–
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Armature supply with extra-low voltage 10 to 50 V
L04
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
✓
Electronics power supply, SINAMICS DC MASTER for connection to 24 V DC
L05
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
24 V DC power supply with SITOP
L06
✓
✓
✓
✓
✓
✓
✓
–
–
✓
✓
✓
✓
✓
✓
24 V DC power supply from an external supply
L07
✓
✓
✓
✓
✓
✓
✓
–
–
✓
✓
✓
✓
✓
✓
24 V DC power supply with SITOP UPS
L09
✓
✓
✓
✓
✓
✓
✓
–
–
✓
✓
✓
✓
✓
✓
Without field power section
L10
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
–
✓
✓
–
Field power section 2Q
L11
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
✓
✓
✓
85 A field power section
L85
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
✓
✓
✓
Radio interference suppression filter
L00
✓
✓
✓
✓
✓
–
✓
✓
✓
✓
✓
✓
✓
–
✓
Elimination of the three-phase commutating reactor
L22
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
Matching transformer for the field supply
Y02
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
✓
✓
✓
Legend
✓
Options can be combined without any restrictions
–
Options cannot be combined
Degree of protection
M21
M23
M43
M54
M58
M59
Degree of protection IP21
M21
–
–
–
–
✓
Degree of protection IP23
M23
–
–
–
–
✓
Degree of protection IP43
M43
–
–
–
–
–
Degree of protection IP54
M54
–
–
–
–
–
Degree or protection IP54 with filter elements
M58
–
–
–
–
–
Cabinet door closed, entry from the bottom through an opening in the floor
M59
✓
✓
–
–
–
Legend
✓
Options can be combined without any restrictions
–
Options cannot be combined
Auxiliary voltage
Y03
Y04
3 AC auxiliary voltage not available
Y03
–
3 AC auxiliary voltage not the same as the standard voltage
Y04
–
Legend
–
Options cannot be combined